Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Fast tonotopy mapping of the rat auditory cortex with a custom-made electrode array

J. Lindovský, K. Pysanenko, J. Popelář, J. Syka

. 2018 ; 67 (6) : 993-998. [pub] 20180911

Language English Country Czech Republic

Document type Journal Article

We present a custom-made multielectrode array for the recording of evoked potentials during acute experiments in rats, which offers a quick and reliable estimation of the cortical tonotopy. The array consists of electrodes represented by insulated copper wires of 0.09 mm diameter fixed in epoxy resin in a 3 x 5 arrangement, with final impedances of 410-800 kOhm. The array was placed on the brain surface of anesthetized rats approximately at the location of the auditory cortex (AC) and the cortical evoked potentials (middle-latency responses, MLR) were elicited by a series of tone pips of different frequencies at 50 dB of sound pressure level (SPL) intensity. The frequency that evoked the highest MLR amplitude (best frequency, BF) was identified for each electrode. The obtained distribution of the BFs characterized the cortical tonotopy, and it correlated with the frequency selectivity of neurons recorded at the same positions by an extracellular microelectrode. Although the space resolution of the array did not allow for the identification of AC sub regions, the array proved to be a reliable tool for a quick estimation and prediction of areas of interest for the subsequent measurements of neurons by more precise techniques.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19004045
003      
CZ-PrNML
005      
20190212140345.0
007      
ta
008      
190124s2018 xr da f 000 0|eng||
009      
AR
024    7_
$a 10.33549/physiolres.933835 $2 doi
035    __
$a (PubMed)30204463
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Lindovský, Jiří $7 xx0232729 $u Department of Auditory Neuroscience, Institute of Experimental Medicine of the Czech Academy of Sciences, Prague
245    10
$a Fast tonotopy mapping of the rat auditory cortex with a custom-made electrode array / $c J. Lindovský, K. Pysanenko, J. Popelář, J. Syka
520    9_
$a We present a custom-made multielectrode array for the recording of evoked potentials during acute experiments in rats, which offers a quick and reliable estimation of the cortical tonotopy. The array consists of electrodes represented by insulated copper wires of 0.09 mm diameter fixed in epoxy resin in a 3 x 5 arrangement, with final impedances of 410-800 kOhm. The array was placed on the brain surface of anesthetized rats approximately at the location of the auditory cortex (AC) and the cortical evoked potentials (middle-latency responses, MLR) were elicited by a series of tone pips of different frequencies at 50 dB of sound pressure level (SPL) intensity. The frequency that evoked the highest MLR amplitude (best frequency, BF) was identified for each electrode. The obtained distribution of the BFs characterized the cortical tonotopy, and it correlated with the frequency selectivity of neurons recorded at the same positions by an extracellular microelectrode. Although the space resolution of the array did not allow for the identification of AC sub regions, the array proved to be a reliable tool for a quick estimation and prediction of areas of interest for the subsequent measurements of neurons by more precise techniques.
650    _2
$a akustická stimulace $x metody $7 D000161
650    _2
$a zvířata $7 D000818
650    _2
$a sluchové korové centrum $x fyziologie $7 D001303
650    _2
$a mapování mozku $x přístrojové vybavení $x metody $7 D001931
650    12
$a implantované elektrody $7 D004567
650    _2
$a sluchové evokované potenciály $x fyziologie $7 D005072
650    _2
$a krysa rodu Rattus $7 D051381
650    _2
$a potkani Long-Evans $7 D020318
650    _2
$a časové faktory $7 D013997
655    _2
$a časopisecké články $7 D016428
700    1_
$a Pysaněnko, Kateryna $7 xx0232507 $u Department of Auditory Neuroscience, Institute of Experimental Medicine of the Czech Academy of Sciences, Prague
700    1_
$a Popelář, Jiří, $d 1949- $7 xx0085571 $u Department of Auditory Neuroscience, Institute of Experimental Medicine of the Czech Academy of Sciences, Prague
700    1_
$a Syka, Josef, $d 1940- $7 jk01122179 $u Department of Auditory Neuroscience, Institute of Experimental Medicine of the Czech Academy of Sciences, Prague
773    0_
$w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 67, č. 6 (2018), s. 993-998
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30204463 $y Pubmed
910    __
$a ABA008 $b A 4120 $c 266 $y 4 $z 0
990    __
$a 20190124 $b ABA008
991    __
$a 20190208103004 $b ABA008
999    __
$a ok $b bmc $g 1375752 $s 1042223
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 67 $c 6 $d 993-998 $e 20180911 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
LZP    __
$b NLK111 $a Pubmed-20190124

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...