Effect of sampling rate on the accuracy of measurement of neonatal oxygen saturation exposure

Thomas Edward Bachman, Karel Roubik

. 2018 ; 48 (3) : 103-107.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc19009355

Patient data management systems are becoming commonplace in the ICU. While their intent is to automate patient charting, they provide a readily accessible, large database that would be potentially useful for clinical research and quality improvement projects. We sought to determine if patient data management information could be of value describing neonatal oxygenation saturation exposure (percent time in oxemic-ranges). Our primary measure was the accuracy of 60-second sampling over a 24-hour period, as compared to previously reported results in 23 infants. We found this to be highly accurate. We also conducted a sensitivity analysis using 3 other sampling rates (20, 30, 120 seconds) and 3 other time epochs (4, 12 and 48 hours). We found that sampling frequency and time epoch length impacted accuracy. Nevertheless these combinations could all be useful, if limitations are taken into account in the analysis design.

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc19009355
003      
CZ-PrNML
005      
20220825145556.0
007      
ta
008      
190314s2018 xr d f 000 0|eng||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Bachman, Thomas E. $7 xx0253545 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno
245    10
$a Effect of sampling rate on the accuracy of measurement of neonatal oxygen saturation exposure / $c Thomas Edward Bachman, Karel Roubik
504    __
$a Literatura
520    9_
$a Patient data management systems are becoming commonplace in the ICU. While their intent is to automate patient charting, they provide a readily accessible, large database that would be potentially useful for clinical research and quality improvement projects. We sought to determine if patient data management information could be of value describing neonatal oxygenation saturation exposure (percent time in oxemic-ranges). Our primary measure was the accuracy of 60-second sampling over a 24-hour period, as compared to previously reported results in 23 infants. We found this to be highly accurate. We also conducted a sensitivity analysis using 3 other sampling rates (20, 30, 120 seconds) and 3 other time epochs (4, 12 and 48 hours). We found that sampling frequency and time epoch length impacted accuracy. Nevertheless these combinations could all be useful, if limitations are taken into account in the analysis design.
650    _7
$a lidé $7 D006801 $2 czmesh
650    17
$a saturace kyslíkem $7 D000089382 $2 czmesh
650    _7
$a nemoci novorozenců $x diagnóza $7 D007232 $2 czmesh
650    17
$a intenzivní péče o novorozence $7 D015931 $2 czmesh
650    _7
$a oxygenoterapie $x metody $7 D010102 $2 czmesh
650    _7
$a oxymetrie $x metody $x přístrojové vybavení $7 D010092 $2 czmesh
650    _7
$a transkutánní měření krevních plynů $x metody $x přístrojové vybavení $7 D001785 $2 czmesh
650    _7
$a sběr dat $7 D003625 $2 czmesh
650    _7
$a analýza dat $7 D000078332 $2 czmesh
655    _7
$a práce podpořená grantem $7 D013485 $2 czmesh
700    1_
$a Roubík, Karel, $d 1971- $7 ntka173892 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 48, č. 3 (2018), s. 103-107 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5221/4922 $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20190313110700 $b ABA008
991    __
$a 20220825145548 $b ABA008
999    __
$a ok $b bmc $g 1384592 $s 1047620
BAS    __
$a 3
BMC    __
$a 2018 $b 48 $c 3 $d 103-107 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$c NLK183 $d 20220825 $a NLK 2019-17/vt

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...