-
Je něco špatně v tomto záznamu ?
Effect of sampling rate on the accuracy of measurement of neonatal oxygen saturation exposure
Thomas Edward Bachman, Karel Roubik
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
- MeSH
- analýza dat MeSH
- intenzivní péče o novorozence * MeSH
- lidé MeSH
- nemoci novorozenců diagnóza MeSH
- oxygenoterapie metody MeSH
- oxymetrie metody přístrojové vybavení MeSH
- saturace kyslíkem * MeSH
- sběr dat MeSH
- transkutánní měření krevních plynů metody přístrojové vybavení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
Patient data management systems are becoming commonplace in the ICU. While their intent is to automate patient charting, they provide a readily accessible, large database that would be potentially useful for clinical research and quality improvement projects. We sought to determine if patient data management information could be of value describing neonatal oxygenation saturation exposure (percent time in oxemic-ranges). Our primary measure was the accuracy of 60-second sampling over a 24-hour period, as compared to previously reported results in 23 infants. We found this to be highly accurate. We also conducted a sensitivity analysis using 3 other sampling rates (20, 30, 120 seconds) and 3 other time epochs (4, 12 and 48 hours). We found that sampling frequency and time epoch length impacted accuracy. Nevertheless these combinations could all be useful, if limitations are taken into account in the analysis design.
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19009355
- 003
- CZ-PrNML
- 005
- 20220825145556.0
- 007
- ta
- 008
- 190314s2018 xr d f 000 0|eng||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Bachman, Thomas E. $7 xx0253545 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno
- 245 10
- $a Effect of sampling rate on the accuracy of measurement of neonatal oxygen saturation exposure / $c Thomas Edward Bachman, Karel Roubik
- 504 __
- $a Literatura
- 520 9_
- $a Patient data management systems are becoming commonplace in the ICU. While their intent is to automate patient charting, they provide a readily accessible, large database that would be potentially useful for clinical research and quality improvement projects. We sought to determine if patient data management information could be of value describing neonatal oxygenation saturation exposure (percent time in oxemic-ranges). Our primary measure was the accuracy of 60-second sampling over a 24-hour period, as compared to previously reported results in 23 infants. We found this to be highly accurate. We also conducted a sensitivity analysis using 3 other sampling rates (20, 30, 120 seconds) and 3 other time epochs (4, 12 and 48 hours). We found that sampling frequency and time epoch length impacted accuracy. Nevertheless these combinations could all be useful, if limitations are taken into account in the analysis design.
- 650 _7
- $a lidé $7 D006801 $2 czmesh
- 650 17
- $a saturace kyslíkem $7 D000089382 $2 czmesh
- 650 _7
- $a nemoci novorozenců $x diagnóza $7 D007232 $2 czmesh
- 650 17
- $a intenzivní péče o novorozence $7 D015931 $2 czmesh
- 650 _7
- $a oxygenoterapie $x metody $7 D010102 $2 czmesh
- 650 _7
- $a oxymetrie $x metody $x přístrojové vybavení $7 D010092 $2 czmesh
- 650 _7
- $a transkutánní měření krevních plynů $x metody $x přístrojové vybavení $7 D001785 $2 czmesh
- 650 _7
- $a sběr dat $7 D003625 $2 czmesh
- 650 _7
- $a analýza dat $7 D000078332 $2 czmesh
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 700 1_
- $a Roubík, Karel, $d 1971- $7 ntka173892 $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno
- 773 0_
- $t Lékař a technika $x 0301-5491 $g Roč. 48, č. 3 (2018), s. 103-107 $w MED00011033
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5221/4922 $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y p $z 0
- 990 __
- $a 20190313110700 $b ABA008
- 991 __
- $a 20220825145548 $b ABA008
- 999 __
- $a ok $b bmc $g 1384592 $s 1047620
- BAS __
- $a 3
- BMC __
- $a 2018 $b 48 $c 3 $d 103-107 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
- LZP __
- $c NLK183 $d 20220825 $a NLK 2019-17/vt