Optimization of diffusion-weighted single-refocused spin-echo EPI by reducing eddy-current artifacts and shortening the echo time
M. Shrestha, P. Hok, U. Nöth, B. Lienerth, R. Deichmann,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články
- MeSH
- algoritmy MeSH
- artefakty MeSH
- difuzní magnetická rezonance * MeSH
- dospělí MeSH
- echoplanární zobrazování * MeSH
- fantomy radiodiagnostické MeSH
- lidé MeSH
- mladý dospělý MeSH
- mozek diagnostické zobrazování MeSH
- počítačová simulace MeSH
- počítačové zpracování obrazu * MeSH
- poměr signál - šum MeSH
- zdraví dobrovolníci pro lékařské studie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: The purpose of this work was to optimize the acquisition of diffusion-weighted (DW) single-refocused spin-echo (srSE) data without intrinsic eddy-current compensation (ECC) for an improved performance of ECC postprocessing. The rationale is that srSE sequences without ECC may yield shorter echo times (TE) and thus higher signal-to-noise ratios (SNR) than srSE or twice-refocused spin-echo (trSE) schemes with intrinsic ECC. MATERIALS AND METHODS: The proposed method employs dummy scans with DW gradients to drive eddy currents into a steady state before data acquisition. Parameters of the ECC postprocessing algorithm were also optimized. Simulations were performed to obtain minimum TE values for the proposed sequence and sequences with intrinsic ECC. Experimentally, the proposed method was compared with standard DW-trSE imaging, both in vitro and in vivo. RESULTS: Simulations showed substantially shorter TE for the proposed method than for methods with intrinsic ECC when using shortened echo readouts. Data of the proposed method showed a marked increase in SNR. A dummy scan duration of at least 1.5 s improved performance of the ECC postprocessing algorithm. CONCLUSION: Changes proposed for the DW-srSE sequence and for the parameter setting of the postprocessing ECC algorithm considerably reduced eddy-current artifacts and provided a higher SNR.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19012746
- 003
- CZ-PrNML
- 005
- 20190412110258.0
- 007
- ta
- 008
- 190405s2018 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10334-018-0684-x $2 doi
- 035 __
- $a (PubMed)29603048
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Shrestha, Manoj $u Brain Imaging Center (BIC), Goethe University Frankfurt, Schleusenweg 2-16, 60528, Frankfurt am Main, Germany. shrestha@med.uni-frankfurt.de.
- 245 10
- $a Optimization of diffusion-weighted single-refocused spin-echo EPI by reducing eddy-current artifacts and shortening the echo time / $c M. Shrestha, P. Hok, U. Nöth, B. Lienerth, R. Deichmann,
- 520 9_
- $a OBJECTIVE: The purpose of this work was to optimize the acquisition of diffusion-weighted (DW) single-refocused spin-echo (srSE) data without intrinsic eddy-current compensation (ECC) for an improved performance of ECC postprocessing. The rationale is that srSE sequences without ECC may yield shorter echo times (TE) and thus higher signal-to-noise ratios (SNR) than srSE or twice-refocused spin-echo (trSE) schemes with intrinsic ECC. MATERIALS AND METHODS: The proposed method employs dummy scans with DW gradients to drive eddy currents into a steady state before data acquisition. Parameters of the ECC postprocessing algorithm were also optimized. Simulations were performed to obtain minimum TE values for the proposed sequence and sequences with intrinsic ECC. Experimentally, the proposed method was compared with standard DW-trSE imaging, both in vitro and in vivo. RESULTS: Simulations showed substantially shorter TE for the proposed method than for methods with intrinsic ECC when using shortened echo readouts. Data of the proposed method showed a marked increase in SNR. A dummy scan duration of at least 1.5 s improved performance of the ECC postprocessing algorithm. CONCLUSION: Changes proposed for the DW-srSE sequence and for the parameter setting of the postprocessing ECC algorithm considerably reduced eddy-current artifacts and provided a higher SNR.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a artefakty $7 D016477
- 650 _2
- $a mozek $x diagnostické zobrazování $7 D001921
- 650 _2
- $a počítačová simulace $7 D003198
- 650 12
- $a difuzní magnetická rezonance $7 D038524
- 650 12
- $a echoplanární zobrazování $7 D017352
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a zdraví dobrovolníci pro lékařské studie $7 D064368
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a počítačové zpracování obrazu $7 D007091
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a fantomy radiodiagnostické $7 D019047
- 650 _2
- $a poměr signál - šum $7 D059629
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hok, Pavel $u Brain Imaging Center (BIC), Goethe University Frankfurt, Schleusenweg 2-16, 60528, Frankfurt am Main, Germany. Department of Neurology, Palacky University Olomouc and University Hospital Olomouc, Olomouc, Czech Republic.
- 700 1_
- $a Nöth, Ulrike $u Brain Imaging Center (BIC), Goethe University Frankfurt, Schleusenweg 2-16, 60528, Frankfurt am Main, Germany.
- 700 1_
- $a Lienerth, Bianca $u Brain Imaging Center (BIC), Goethe University Frankfurt, Schleusenweg 2-16, 60528, Frankfurt am Main, Germany.
- 700 1_
- $a Deichmann, Ralf $u Brain Imaging Center (BIC), Goethe University Frankfurt, Schleusenweg 2-16, 60528, Frankfurt am Main, Germany.
- 773 0_
- $w MED00006146 $t Magma (New York, N.Y.) $x 1352-8661 $g Roč. 31, č. 5 (2018), s. 585-597
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29603048 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190405 $b ABA008
- 991 __
- $a 20190412110317 $b ABA008
- 999 __
- $a ok $b bmc $g 1392056 $s 1051051
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 31 $c 5 $d 585-597 $e 20180330 $i 1352-8661 $m Magma $n MAGMA $x MED00006146
- LZP __
- $a Pubmed-20190405