Je něco špatně v tomto záznamu ?
Three-layer collagen-based vascular graft designed for low-flow peripheral vascular reconstructions
Miroslav Špaček, Hynek Chlup, Petr Mitáš, Jan Veselý, Lukas Lambert, Mikuláš Mlček, Milan Krajíček, Jaroslav Lindner, Tomáš Grus
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
Grantová podpora
NV15-27941A
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
Directory of Open Access Journals
od 2019
ROAD: Directory of Open Access Scholarly Resources
od 2002
- MeSH
- cévní protézy * MeSH
- cévy - implantace protéz metody MeSH
- chirurgické síťky MeSH
- kolagen terapeutické užití MeSH
- mechanický stres MeSH
- složené pryskyřice MeSH
- vena saphena transplantace MeSH
- Publikační typ
- práce podpořená grantem MeSH
Introduction: The aim of this study was to develop a prototype of an artificial blood vessel which has similar mechanical properties to a human saphenous vein graft and to experimentally verify the function of the prosthesis via ovine carotid bypass implantation. Material and methods: The prototype of an artificial graft prosthesis for low flow was developed and manufactured from a collagenous matrix and reinforcing polyester mesh. We compared the results of both the pressurisation and the mechanical stress evaluation tests of VSM with four types of hybrid vascular graft. The most similar graft (type II) was chosen for the first ovine model implantation. Results: Dominant behavior e.g. mechanical response of VSM graft in plots of circumferential and axial stress during loading is observed in circumferential direction. Average results of used VSM showed area of ideal mechanical response and the properties of artificial blood vessels were fitted into this area. Developed graft remained patent after 161 days of follow up in ovine model. Conclusions: The mechanical properties of the graft were designed and adjusted to be similar to the behaviour of human saphenous veins. This approach showed promising results and enhanced the final performance of the prosthesis.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19019276
- 003
- CZ-PrNML
- 005
- 20201020112406.0
- 007
- ta
- 008
- 190601s2019 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.32725/jab.2019.002 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Špaček, Miroslav $7 xx0160372 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
- 245 10
- $a Three-layer collagen-based vascular graft designed for low-flow peripheral vascular reconstructions / $c Miroslav Špaček, Hynek Chlup, Petr Mitáš, Jan Veselý, Lukas Lambert, Mikuláš Mlček, Milan Krajíček, Jaroslav Lindner, Tomáš Grus
- 504 __
- $a Literatura
- 520 9_
- $a Introduction: The aim of this study was to develop a prototype of an artificial blood vessel which has similar mechanical properties to a human saphenous vein graft and to experimentally verify the function of the prosthesis via ovine carotid bypass implantation. Material and methods: The prototype of an artificial graft prosthesis for low flow was developed and manufactured from a collagenous matrix and reinforcing polyester mesh. We compared the results of both the pressurisation and the mechanical stress evaluation tests of VSM with four types of hybrid vascular graft. The most similar graft (type II) was chosen for the first ovine model implantation. Results: Dominant behavior e.g. mechanical response of VSM graft in plots of circumferential and axial stress during loading is observed in circumferential direction. Average results of used VSM showed area of ideal mechanical response and the properties of artificial blood vessels were fitted into this area. Developed graft remained patent after 161 days of follow up in ovine model. Conclusions: The mechanical properties of the graft were designed and adjusted to be similar to the behaviour of human saphenous veins. This approach showed promising results and enhanced the final performance of the prosthesis.
- 650 12
- $a cévní protézy $7 D001807
- 650 _2
- $a kolagen $x terapeutické užití $7 D003094
- 650 _2
- $a chirurgické síťky $7 D013526
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a vena saphena $x transplantace $7 D012501
- 650 _2
- $a cévy - implantace protéz $x metody $7 D019917
- 650 _2
- $a složené pryskyřice $7 D003188
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Chlup, Hynek $7 xx0210944 $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Mechanics, Biomechanics and Mechatronics, Prague, Czech Republic
- 700 1_
- $a Mitáš, Petr $7 xx0158090 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
- 700 1_
- $a Veselý, Jan $7 xx0210945 $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Mechanics, Biomechanics and Mechatronics, Prague, Czech Republic
- 700 1_
- $a Lambert, Lukáš $7 xx0145830 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, Department of Radiology, Prague, Czech Republic
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Charles University, First Faculty of Medicine, Institute of Physiology, Prague, Czech Republic
- 700 1_
- $a Krajíček, Milan, $d 1933-2016 $7 nlk19990073424 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
- 700 1_
- $a Lindner, Jaroslav, $d 1957- $7 mzk2005269705 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
- 700 1_
- $a Grus, Tomáš, $d 1974- $7 xx0080427 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
- 773 0_
- $t Journal of applied biomedicine $x 1214-021X $g Roč. 17, č. 1 (2019), s. 47-52 $w MED00012667
- 856 41
- $u https://jab.zsf.jcu.cz/pdfs/jab/2019/01/07.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 2301 $c 1249 $y p $z 0
- 990 __
- $a 20190601070112 $b ABA008
- 991 __
- $a 20201020112403 $b ABA008
- 999 __
- $a ok $b bmc $g 1410858 $s 1059155
- BAS __
- $a 3
- BMC __
- $a 2019 $b 17 $c 1 $d 47-52 $i 1214-021X $m Journal of Applied Biomedicine $x MED00012667
- GRA __
- $a NV15-27941A $p MZ0
- LZP __
- $c NLK125 $d 20200113 $a NLK 2019-30/vt