Three-layer collagen-based vascular graft designed for low-flow peripheral vascular reconstructions

Miroslav Špaček, Hynek Chlup, Petr Mitáš, Jan Veselý, Lukas Lambert, Mikuláš Mlček, Milan Krajíček, Jaroslav Lindner, Tomáš Grus

. 2019 ; 17 (1) : 47-52.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc19019276

Grantová podpora
NV15-27941A MZ0 CEP - Centrální evidence projektů

Introduction: The aim of this study was to develop a prototype of an artificial blood vessel which has similar mechanical properties to a human saphenous vein graft and to experimentally verify the function of the prosthesis via ovine carotid bypass implantation. Material and methods: The prototype of an artificial graft prosthesis for low flow was developed and manufactured from a collagenous matrix and reinforcing polyester mesh. We compared the results of both the pressurisation and the mechanical stress evaluation tests of VSM with four types of hybrid vascular graft. The most similar graft (type II) was chosen for the first ovine model implantation. Results: Dominant behavior e.g. mechanical response of VSM graft in plots of circumferential and axial stress during loading is observed in circumferential direction. Average results of used VSM showed area of ideal mechanical response and the properties of artificial blood vessels were fitted into this area. Developed graft remained patent after 161 days of follow up in ovine model. Conclusions: The mechanical properties of the graft were designed and adjusted to be similar to the behaviour of human saphenous veins. This approach showed promising results and enhanced the final performance of the prosthesis.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc19019276
003      
CZ-PrNML
005      
20201020112406.0
007      
ta
008      
190601s2019 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.32725/jab.2019.002 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Špaček, Miroslav $7 xx0160372 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
245    10
$a Three-layer collagen-based vascular graft designed for low-flow peripheral vascular reconstructions / $c Miroslav Špaček, Hynek Chlup, Petr Mitáš, Jan Veselý, Lukas Lambert, Mikuláš Mlček, Milan Krajíček, Jaroslav Lindner, Tomáš Grus
504    __
$a Literatura
520    9_
$a Introduction: The aim of this study was to develop a prototype of an artificial blood vessel which has similar mechanical properties to a human saphenous vein graft and to experimentally verify the function of the prosthesis via ovine carotid bypass implantation. Material and methods: The prototype of an artificial graft prosthesis for low flow was developed and manufactured from a collagenous matrix and reinforcing polyester mesh. We compared the results of both the pressurisation and the mechanical stress evaluation tests of VSM with four types of hybrid vascular graft. The most similar graft (type II) was chosen for the first ovine model implantation. Results: Dominant behavior e.g. mechanical response of VSM graft in plots of circumferential and axial stress during loading is observed in circumferential direction. Average results of used VSM showed area of ideal mechanical response and the properties of artificial blood vessels were fitted into this area. Developed graft remained patent after 161 days of follow up in ovine model. Conclusions: The mechanical properties of the graft were designed and adjusted to be similar to the behaviour of human saphenous veins. This approach showed promising results and enhanced the final performance of the prosthesis.
650    12
$a cévní protézy $7 D001807
650    _2
$a kolagen $x terapeutické užití $7 D003094
650    _2
$a chirurgické síťky $7 D013526
650    _2
$a mechanický stres $7 D013314
650    _2
$a vena saphena $x transplantace $7 D012501
650    _2
$a cévy - implantace protéz $x metody $7 D019917
650    _2
$a složené pryskyřice $7 D003188
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Chlup, Hynek $7 xx0210944 $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Mechanics, Biomechanics and Mechatronics, Prague, Czech Republic
700    1_
$a Mitáš, Petr $7 xx0158090 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
700    1_
$a Veselý, Jan $7 xx0210945 $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Department of Mechanics, Biomechanics and Mechatronics, Prague, Czech Republic
700    1_
$a Lambert, Lukáš $7 xx0145830 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, Department of Radiology, Prague, Czech Republic
700    1_
$a Mlček, Mikuláš $7 xx0106453 $u Charles University, First Faculty of Medicine, Institute of Physiology, Prague, Czech Republic
700    1_
$a Krajíček, Milan, $d 1933-2016 $7 nlk19990073424 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
700    1_
$a Lindner, Jaroslav, $d 1957- $7 mzk2005269705 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
700    1_
$a Grus, Tomáš, $d 1974- $7 xx0080427 $u Charles University and General University Hospital in Prague, First Faculty of Medicine, 2nd Department of Surgery - Department of Cardiovascular Surgery, Prague, Czech Republic
773    0_
$t Journal of applied biomedicine $x 1214-021X $g Roč. 17, č. 1 (2019), s. 47-52 $w MED00012667
856    41
$u https://jab.zsf.jcu.cz/pdfs/jab/2019/01/07.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 2301 $c 1249 $y p $z 0
990    __
$a 20190601070112 $b ABA008
991    __
$a 20201020112403 $b ABA008
999    __
$a ok $b bmc $g 1410858 $s 1059155
BAS    __
$a 3
BMC    __
$a 2019 $b 17 $c 1 $d 47-52 $i 1214-021X $m Journal of Applied Biomedicine $x MED00012667
GRA    __
$a NV15-27941A $p MZ0
LZP    __
$c NLK125 $d 20200113 $a NLK 2019-30/vt

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...