Automated continuous-flow in-syringe dispersive liquid-liquid microextraction of mono-nitrophenols from large sample volumes using a novel approach to multivariate spectral analysis

K. Fikarová, B. Horstkotte, H. Sklenářová, F. Švec, P. Solich,

. 2019 ; 202 (-) : 11-20. [pub] 20190421

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028909

Continuous magnetic stirring-assisted dispersive liquid-liquid extraction followed by dispersive backextraction as a novel pre-treatment technique for adaptable and milliliter volumes of environmental samples has been developed. The procedure was automated using the technique "Lab-In-Syringe". The void of the automated syringe pump was used as size-adaptable extraction chamber. By a flow channel in the syringe piston, continuous flow through the syringe void was enabled. 1-Octanol was used as an extractant and dispersed by the action of a magnetic stirring bar, which was placed inside the syringe and driven by an external rotating magnetic field. Extract washing and dispersive backextraction in an alkaline aqueous acceptor phase were carried out after the preceding extraction from the acidified water sample. Analyte determination was achieved using multivariate spectrum analysis. The method was applied to determine priority pollutants, mono-nitrophenols, in surface water and enabled to reach limits of detection for o-, m-, p-nitrophenol (λ = 418, 390, 400 nm, respectively) of 0.14, 0.26, and 0.02 μmol L-1 (19.5, 36.2, and 2.8 μg L-1), respectively. Under optimized conditions, relative standard deviations were generally less than 5% and enrichment factors of o-, m-, p-nitrophenol 19, 25, and 21, respectively, were achieved using sample volumes of up to 24 mL. Average recoveries of o-, m-, p-nitrophenol from spiked surface water were 94, 82, and 92%, respectively. The concentration of humic acid was found 6-times reduced with respect to the analyte. In addition, adding spectral background modeling allowed nitrophenol determination with precision adequate for routine analysis.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028909
003      
CZ-PrNML
005      
20190816121424.0
007      
ta
008      
190813s2019 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2019.04.044 $2 doi
035    __
$a (PubMed)31171158
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Fikarová, K $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic.
245    10
$a Automated continuous-flow in-syringe dispersive liquid-liquid microextraction of mono-nitrophenols from large sample volumes using a novel approach to multivariate spectral analysis / $c K. Fikarová, B. Horstkotte, H. Sklenářová, F. Švec, P. Solich,
520    9_
$a Continuous magnetic stirring-assisted dispersive liquid-liquid extraction followed by dispersive backextraction as a novel pre-treatment technique for adaptable and milliliter volumes of environmental samples has been developed. The procedure was automated using the technique "Lab-In-Syringe". The void of the automated syringe pump was used as size-adaptable extraction chamber. By a flow channel in the syringe piston, continuous flow through the syringe void was enabled. 1-Octanol was used as an extractant and dispersed by the action of a magnetic stirring bar, which was placed inside the syringe and driven by an external rotating magnetic field. Extract washing and dispersive backextraction in an alkaline aqueous acceptor phase were carried out after the preceding extraction from the acidified water sample. Analyte determination was achieved using multivariate spectrum analysis. The method was applied to determine priority pollutants, mono-nitrophenols, in surface water and enabled to reach limits of detection for o-, m-, p-nitrophenol (λ = 418, 390, 400 nm, respectively) of 0.14, 0.26, and 0.02 μmol L-1 (19.5, 36.2, and 2.8 μg L-1), respectively. Under optimized conditions, relative standard deviations were generally less than 5% and enrichment factors of o-, m-, p-nitrophenol 19, 25, and 21, respectively, were achieved using sample volumes of up to 24 mL. Average recoveries of o-, m-, p-nitrophenol from spiked surface water were 94, 82, and 92%, respectively. The concentration of humic acid was found 6-times reduced with respect to the analyte. In addition, adding spectral background modeling allowed nitrophenol determination with precision adequate for routine analysis.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Horstkotte, B $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic. Electronic address: Horstkob@faf.cuni.cz.
700    1_
$a Sklenářová, H $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic.
700    1_
$a Švec, F $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic.
700    1_
$a Solich, P $u Charles University, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Akademika Heyrovského 1203, 500 05, Hradec Králové, Czech Republic.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 202, č. - (2019), s. 11-20
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31171158 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190816121653 $b ABA008
999    __
$a ind $b bmc $g 1434058 $s 1067369
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 202 $c - $d 11-20 $e 20190421 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...