Something wrong with this record ?
Detection of microembolic signals in the common carotid artery using Doppler sonography in the porcine model of acute heart failure treated by veno-arterial extracorporeal membrane oxygenation
D. Janák, P. Hála, M. Mlček, M. Popková, S. Lacko, J. Kudlička, O. Kittnar
Language English Country Czech Republic
Document type Journal Article
NLK
Directory of Open Access Journals
from 1991
Free Medical Journals
from 1998
ProQuest Central
from 2005-01-01
Medline Complete (EBSCOhost)
from 2006-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
Health & Medicine (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1998
- MeSH
- Acute Disease MeSH
- Carotid Artery, Common diagnostic imaging physiopathology MeSH
- Embolism diagnostic imaging physiopathology MeSH
- Microcirculation physiology MeSH
- Extracorporeal Membrane Oxygenation adverse effects trends MeSH
- Disease Models, Animal * MeSH
- Swine MeSH
- Blood Flow Velocity physiology MeSH
- Heart Failure diagnostic imaging physiopathology therapy MeSH
- Ultrasonography, Doppler methods trends MeSH
- Animals MeSH
- Check Tag
- Female MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19030483
- 003
- CZ-PrNML
- 005
- 20200309151700.0
- 007
- ta
- 008
- 190830s2017 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933806 $2 doi
- 035 __
- $a (PubMed)29355381
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Janák, David $7 xx0232166 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic; Department of Cardiovascular Surgery, Second Faculty of Medicine, Charles University and University Hospital Motol, Prague, Czech Republic
- 245 10
- $a Detection of microembolic signals in the common carotid artery using Doppler sonography in the porcine model of acute heart failure treated by veno-arterial extracorporeal membrane oxygenation / $c D. Janák, P. Hála, M. Mlček, M. Popková, S. Lacko, J. Kudlička, O. Kittnar
- 520 9_
- $a Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
- 650 _2
- $a akutní nemoc $7 D000208
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a rychlost toku krve $x fyziologie $7 D001783
- 650 _2
- $a arteria carotis communis $x diagnostické zobrazování $x patofyziologie $7 D017536
- 650 12
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a embolie $x diagnostické zobrazování $x patofyziologie $7 D004617
- 650 _2
- $a mimotělní membránová oxygenace $x škodlivé účinky $x trendy $7 D015199
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a srdeční selhání $x diagnostické zobrazování $x patofyziologie $x terapie $7 D006333
- 650 _2
- $a mikrocirkulace $x fyziologie $7 D008833
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a ultrasonografie dopplerovská $x metody $x trendy $7 D018608
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hála, Pavel $7 xx0232154 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Popková, Michaela $7 xx0232222 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Lacko, Stanislav $7 xx0232217 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Kudlička, Jaroslav, $d 1984- $7 xx0211199 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Kittnar, Otomar, $d 1953- $7 jn20000710185 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 66, Supplementum 4 (2017), s. S529-S536
- 773 0_
- $t Proceedings of the ... Physiological days : $g (2017), s. S529-S536 $w MED00183838
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29355381 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20190830 $b ABA008
- 991 __
- $a 20200309152117 $b ABA008
- 999 __
- $a ok $b bmc $g 1440120 $s 1068971
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 66 $c Supplementum 4 $d S529-S536 $e 2017Dec30 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- BMC __
- $a 2017 $d S529-S536 $m Proceedings of the ... Physiological days $x MED00183838
- LZP __
- $b NLK118 $a Pubmed-20190830