Detection of microembolic signals in the common carotid artery using Doppler sonography in the porcine model of acute heart failure treated by veno-arterial extracorporeal membrane oxygenation
D. Janák, P. Hála, M. Mlček, M. Popková, S. Lacko, J. Kudlička, O. Kittnar
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- akutní nemoc MeSH
- arteria carotis communis diagnostické zobrazování patofyziologie MeSH
- embolie diagnostické zobrazování patofyziologie MeSH
- mikrocirkulace fyziologie MeSH
- mimotělní membránová oxygenace škodlivé účinky trendy MeSH
- modely nemocí na zvířatech * MeSH
- prasata MeSH
- rychlost toku krve fyziologie MeSH
- srdeční selhání diagnostické zobrazování patofyziologie terapie MeSH
- ultrasonografie dopplerovská metody trendy MeSH
- zvířata MeSH
- Check Tag
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19030483
- 003
- CZ-PrNML
- 005
- 20200309151700.0
- 007
- ta
- 008
- 190830s2017 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933806 $2 doi
- 035 __
- $a (PubMed)29355381
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Janák, David $7 xx0232166 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic; Department of Cardiovascular Surgery, Second Faculty of Medicine, Charles University and University Hospital Motol, Prague, Czech Republic
- 245 10
- $a Detection of microembolic signals in the common carotid artery using Doppler sonography in the porcine model of acute heart failure treated by veno-arterial extracorporeal membrane oxygenation / $c D. Janák, P. Hála, M. Mlček, M. Popková, S. Lacko, J. Kudlička, O. Kittnar
- 520 9_
- $a Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.
- 650 _2
- $a akutní nemoc $7 D000208
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a rychlost toku krve $x fyziologie $7 D001783
- 650 _2
- $a arteria carotis communis $x diagnostické zobrazování $x patofyziologie $7 D017536
- 650 12
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a embolie $x diagnostické zobrazování $x patofyziologie $7 D004617
- 650 _2
- $a mimotělní membránová oxygenace $x škodlivé účinky $x trendy $7 D015199
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a srdeční selhání $x diagnostické zobrazování $x patofyziologie $x terapie $7 D006333
- 650 _2
- $a mikrocirkulace $x fyziologie $7 D008833
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a ultrasonografie dopplerovská $x metody $x trendy $7 D018608
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hála, Pavel $7 xx0232154 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Popková, Michaela $7 xx0232222 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Lacko, Stanislav $7 xx0232217 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Kudlička, Jaroslav, $d 1984- $7 xx0211199 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Kittnar, Otomar, $d 1953- $7 jn20000710185 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 66, Supplementum 4 (2017), s. S529-S536
- 773 0_
- $t Proceedings of the ... Physiological days : $g (2017), s. S529-S536 $w MED00183838
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29355381 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20190830 $b ABA008
- 991 __
- $a 20200309152117 $b ABA008
- 999 __
- $a ok $b bmc $g 1440120 $s 1068971
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 66 $c Supplementum 4 $d S529-S536 $e 2017Dec30 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- BMC __
- $a 2017 $d S529-S536 $m Proceedings of the ... Physiological days $x MED00183838
- LZP __
- $b NLK118 $a Pubmed-20190830