-
Something wrong with this record ?
Nová metoda rekonstrukce předního zkříženého vazu kolenního kloubu pomocí hamstringů – klinická část [New anterior cruciate ligament reconstrucion using harmstring tendon grafts - clinical part]
M. Hanus, M. Handl, A. Stančák, T. Trč
Language Czech Country Czech Republic
Document type Journal Article
PubMed
30843513
- MeSH
- Adult MeSH
- Knee Joint MeSH
- Middle Aged MeSH
- Humans MeSH
- Anterior Cruciate Ligament MeSH
- Adolescent MeSH
- Young Adult MeSH
- Joint Instability * MeSH
- Anterior Cruciate Ligament Injuries * MeSH
- Anterior Cruciate Ligament Reconstruction * MeSH
- Tendons MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
PURPOSE OF THE STUDY The authors present the clinical use of the new instrumentation set for the anterior cruciate ligament (ACL) reconstruction using the hamstring tendons (HS). The positionning of the femoral tunnel and the fixation of the graft play an important role for the results of the surgery. The aim of the study was to confirm the proposed surgical technique and the methods of the graft fixation, especially from the point of view of the clinical midterm results at the evaluation up to eight years after the surgery. MATERIAL AND METHODS The clinical evaluation comprises 58 patients operated from 2007 to 2014 using the new instrumentation set. There were 9 men and 49 women included in the sample. The mean age was 34.6 years (range 18 - 58 yrs), namely 36.7 in women and 32.4 years in men. The evaluation was performed pre-opeatively and at 3 and 6 months, 1, 3, 5 and 8 years post-operatively. All the patients were followed based on the same criteria - clinical range of motion (ROM), stability of the knee - instrumentation Lachman test utilizing Rolimeter, subjective IKDC score and pain VAS scale for the harvesting site. The ocurrence and the rate of post-operative complications were monitored. RESULTS The integration and the ingrowth of the graft were achieved in all cases, the full ROM was gained as well, no pathological instability was observed. The fixation of the HS graft in the bone was confirmed by post-op X ray at 3 months after the surgery. The clinical evaluation showed the following mean differences in the pre-op and final post-op findings. The average preoperative laxity using the Lachmann test was 9.7 mm (range 6-12 mm), at 3 months 1.8 mm (1.4-2.1 mm), at 6 months 1.6 mm (1.2 - 2.2 mm), at 1 year 1.6 mm (1.1-2.3 mm), at 3 years the stability was 1.7 mm (1.2 mm-2.4 mm), at 5 years 2.3 mm (1.2-3.6 mm) and at 8 years after surgery it was 2.5 mm (1.2-3.9 mm). None of the patitents included in the study showed pathological instability that would be considered an indication for revision. In the evaluation of the subjective IKDC score, the pre-operative average was 56, with the range of 42-66, at 3 months post-operatively 79 (69-85), at 6 months 88 (74-92), at 1 year 95 (88-100), at 3 years 96 (89-100), at 5 years 94 (87-100), and at 8 years 92 (84-98). No severe complications were observed. CONCLUSIONS The method provided sufficient post-operative stability of the knee joint. Fixation of the femoral screw satisfied the demands laid on it. Regarding the pain perception, the method was considered positive, the level of pain involved in the procedure was low. No severe complications or technical mistakes occurred during the surgical procedures. The new instrumentation set developed for the ACL reconstruction offers an easy technique and comfortof use. Key words:anterior cruciate ligament, reconstruction, hamstrings, knee arthroscopy, instrumentation set.
Dubai Bone and Joint Center Dubai Spojené arabské emiráty
Fakulta biomedicínského inženýrství Českého vysokého učení technického Praha Kladno ČR
New anterior cruciate ligament reconstrucion using harmstring tendon grafts - clinical part
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19030789
- 003
- CZ-PrNML
- 005
- 20190913131722.0
- 007
- ta
- 008
- 190902s2019 xr f 000 0|cze||
- 009
- AR
- 024 7_
- $2 doi $a 10.55095/achot2019/007
- 035 __
- $a (PubMed)30843513
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a cze
- 044 __
- $a xr
- 100 1_
- $a Hanus, Martin $7 xx0062704 $u Klinika dětské a dospělé ortopedie a traumatologie 2. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha, ČR
- 245 10
- $a Nová metoda rekonstrukce předního zkříženého vazu kolenního kloubu pomocí hamstringů – klinická část / $c M. Hanus, M. Handl, A. Stančák, T. Trč
- 246 31
- $a New anterior cruciate ligament reconstrucion using harmstring tendon grafts - clinical part
- 520 9_
- $a PURPOSE OF THE STUDY The authors present the clinical use of the new instrumentation set for the anterior cruciate ligament (ACL) reconstruction using the hamstring tendons (HS). The positionning of the femoral tunnel and the fixation of the graft play an important role for the results of the surgery. The aim of the study was to confirm the proposed surgical technique and the methods of the graft fixation, especially from the point of view of the clinical midterm results at the evaluation up to eight years after the surgery. MATERIAL AND METHODS The clinical evaluation comprises 58 patients operated from 2007 to 2014 using the new instrumentation set. There were 9 men and 49 women included in the sample. The mean age was 34.6 years (range 18 - 58 yrs), namely 36.7 in women and 32.4 years in men. The evaluation was performed pre-opeatively and at 3 and 6 months, 1, 3, 5 and 8 years post-operatively. All the patients were followed based on the same criteria - clinical range of motion (ROM), stability of the knee - instrumentation Lachman test utilizing Rolimeter, subjective IKDC score and pain VAS scale for the harvesting site. The ocurrence and the rate of post-operative complications were monitored. RESULTS The integration and the ingrowth of the graft were achieved in all cases, the full ROM was gained as well, no pathological instability was observed. The fixation of the HS graft in the bone was confirmed by post-op X ray at 3 months after the surgery. The clinical evaluation showed the following mean differences in the pre-op and final post-op findings. The average preoperative laxity using the Lachmann test was 9.7 mm (range 6-12 mm), at 3 months 1.8 mm (1.4-2.1 mm), at 6 months 1.6 mm (1.2 - 2.2 mm), at 1 year 1.6 mm (1.1-2.3 mm), at 3 years the stability was 1.7 mm (1.2 mm-2.4 mm), at 5 years 2.3 mm (1.2-3.6 mm) and at 8 years after surgery it was 2.5 mm (1.2-3.9 mm). None of the patitents included in the study showed pathological instability that would be considered an indication for revision. In the evaluation of the subjective IKDC score, the pre-operative average was 56, with the range of 42-66, at 3 months post-operatively 79 (69-85), at 6 months 88 (74-92), at 1 year 95 (88-100), at 3 years 96 (89-100), at 5 years 94 (87-100), and at 8 years 92 (84-98). No severe complications were observed. CONCLUSIONS The method provided sufficient post-operative stability of the knee joint. Fixation of the femoral screw satisfied the demands laid on it. Regarding the pain perception, the method was considered positive, the level of pain involved in the procedure was low. No severe complications or technical mistakes occurred during the surgical procedures. The new instrumentation set developed for the ACL reconstruction offers an easy technique and comfortof use. Key words:anterior cruciate ligament, reconstruction, hamstrings, knee arthroscopy, instrumentation set.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a ligamentum cruciatum anterius $7 D016118
- 650 12
- $a poranění předního zkříženého vazu $7 D000070598
- 650 12
- $a rekonstrukce předního zkříženého vazu $7 D059549
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a nestabilita kloubu $7 D007593
- 650 _2
- $a kolenní kloub $7 D007719
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a šlachy $7 D013710
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Handl, Milan, $d 1961- $7 xx0064271 $u Klinika dětské a dospělé ortopedie a traumatologie 2. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha, ČR; Fakulta biomedicínského inženýrství Českého vysokého učení technického v Praze, Kladno, ČR; Dubai Bone and Joint Center, Dubai, Spojené arabské emiráty
- 700 1_
- $a Stančák, Andrej $7 xx0231822 $u Klinika dětské a dospělé ortopedie a traumatologie 2. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha, ČR
- 700 1_
- $a Trč, Tomáš, $d 1955- $7 nlk19990073953 $u Klinika dětské a dospělé ortopedie a traumatologie 2. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice v Motole, Praha, ČR
- 773 0_
- $w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 86, č. 1 (2019), s. 46-50
- 910 __
- $a ABA008 $b A 8 $c 507 $y 4 $z 0
- 990 __
- $a 20190902 $b ABA008
- 991 __
- $a 20190912150009 $b ABA008
- 999 __
- $a ok $b bmc $g 1442930 $s 1069278
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 86 $c 1 $d 46-50 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
- LZP __
- $b NLK118 $a Pubmed-20190902