High-sensitivity 5-, 6-, and 7-color PNH WBC assays for both Canto II and Navios platforms

DR. Sutherland, F. Ortiz, G. Quest, A. Illingworth, M. Benko, R. Nayyar, I. Marinov,

. 2018 ; 94 (4) : 637-651. [pub] 20180305

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19035425

BACKGROUND: Paroxysmal Nocturnal Hemoglobinuria (PNH) is a rare acquired hematopoietic stem cell disorder characterized by an inability to make Glyco-Phosphatidyl-Inositol (GPI)-linked cell surface structures. Fluorescent proaerolysin (FLAER-Alexa488) is increasingly used to detect GPI-deficient WBCs by flow cytometry. However, FLAER is not available in all countries and is expensive to obtain in others. An earlier study to compare FLAER-based and non-FLAER assays confirmed very good agreement between the two tubes suggesting a cost effective simultaneous evaluation of PNH neutrophils and monocytes is possible without FLAER. METHODS: We have used a single tube approach with a 7-color assay comprising FLAER-CD157-CD15-CD64-CD24-CD14-CD45. Conjugates were carefully selected and validated so that stained samples could be analyzed on either 10-color Navios or 8-color FACSCanto II platforms. The 6-color (minus CD14) and 5-color (minus CD24 and CD14) versions were also developed and compared with our predicate clinical lab 5-color assay comprising FLAER-CD157PE-CD64ECD-CD15PC5-CD45PC7. RESULTS/CONCLUSIONS: CD15-gated PNH neutrophil clone size was quantified using either FLAER and CD157, FLAER and CD24, or CD157 and CD24. CD64-gated PNH monocyte clone size was quantified using either FLAER and CD157, FLAER and CD14, or CD157 and CD14. Analysis of >40 PNH samples showed that the FLAER-based plots derive virtually identical data to the non-FLAER plot for neutrophils (R2  = 1) and monocytes (R2  = 0.9999) and that closely similar data can be acquired using both Canto II and Navios platforms with 7-, 6-, and 5-color versions of the assay. Assessment of non-PNH samples confirmed extremely low background rate of PNH phenotypes (neutrophils and monocytes) with all three approaches. © 2018 International Clinical Cytometry Society.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19035425
003      
CZ-PrNML
005      
20191014092828.0
007      
ta
008      
191007s2018 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1002/cyto.b.21626 $2 doi
035    __
$a (PubMed)29381839
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Sutherland, D Robert $u Laboratory Medicine Program, Toronto General Hospital, Ontario, Canada.
245    10
$a High-sensitivity 5-, 6-, and 7-color PNH WBC assays for both Canto II and Navios platforms / $c DR. Sutherland, F. Ortiz, G. Quest, A. Illingworth, M. Benko, R. Nayyar, I. Marinov,
520    9_
$a BACKGROUND: Paroxysmal Nocturnal Hemoglobinuria (PNH) is a rare acquired hematopoietic stem cell disorder characterized by an inability to make Glyco-Phosphatidyl-Inositol (GPI)-linked cell surface structures. Fluorescent proaerolysin (FLAER-Alexa488) is increasingly used to detect GPI-deficient WBCs by flow cytometry. However, FLAER is not available in all countries and is expensive to obtain in others. An earlier study to compare FLAER-based and non-FLAER assays confirmed very good agreement between the two tubes suggesting a cost effective simultaneous evaluation of PNH neutrophils and monocytes is possible without FLAER. METHODS: We have used a single tube approach with a 7-color assay comprising FLAER-CD157-CD15-CD64-CD24-CD14-CD45. Conjugates were carefully selected and validated so that stained samples could be analyzed on either 10-color Navios or 8-color FACSCanto II platforms. The 6-color (minus CD14) and 5-color (minus CD24 and CD14) versions were also developed and compared with our predicate clinical lab 5-color assay comprising FLAER-CD157PE-CD64ECD-CD15PC5-CD45PC7. RESULTS/CONCLUSIONS: CD15-gated PNH neutrophil clone size was quantified using either FLAER and CD157, FLAER and CD24, or CD157 and CD24. CD64-gated PNH monocyte clone size was quantified using either FLAER and CD157, FLAER and CD14, or CD157 and CD14. Analysis of >40 PNH samples showed that the FLAER-based plots derive virtually identical data to the non-FLAER plot for neutrophils (R2  = 1) and monocytes (R2  = 0.9999) and that closely similar data can be acquired using both Canto II and Navios platforms with 7-, 6-, and 5-color versions of the assay. Assessment of non-PNH samples confirmed extremely low background rate of PNH phenotypes (neutrophils and monocytes) with all three approaches. © 2018 International Clinical Cytometry Society.
650    _2
$a CD antigeny $x analýza $7 D015703
650    _2
$a průtoková cytometrie $x přístrojové vybavení $x metody $7 D005434
650    _2
$a paroxysmální hemoglobinurie $x diagnóza $7 D006457
650    _2
$a lidé $7 D006801
650    _2
$a imunofenotypizace $x přístrojové vybavení $x metody $7 D016130
650    _2
$a senzitivita a specificita $7 D012680
655    _2
$a časopisecké články $7 D016428
700    1_
$a Ortiz, Fernando $u Cytoquest Corporation, Toronto, Ontario, Canada.
700    1_
$a Quest, Graeme $u Laboratory Medicine Program, Toronto General Hospital, Ontario, Canada.
700    1_
$a Illingworth, Andrea $u Dahl-Chase Diagnostic Services, Bangor, Maine.
700    1_
$a Benko, Miroslav $u EXBIO Praha, a.s. Vestec, Czech Republic.
700    1_
$a Nayyar, Rakesh $u Cytoquest Corporation, Toronto, Ontario, Canada.
700    1_
$a Marinov, Iuri $u Institute of Hematology and Blood Transfusion, Prague, Czech Republic.
773    0_
$w MED00013936 $t Cytometry. Part B, Clinical cytometry $x 1552-4957 $g Roč. 94, č. 4 (2018), s. 637-651
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29381839 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20191007 $b ABA008
991    __
$a 20191014093252 $b ABA008
999    __
$a ok $b bmc $g 1452085 $s 1073975
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 94 $c 4 $d 637-651 $e 20180305 $i 1552-4957 $m Cytometry. Part B, Clinical cytometry $n Cytometry B Clin Cytom $x MED00013936
LZP    __
$a Pubmed-20191007

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace