Use of a right ventricular continuous flow pump to validate the distensible model of the pulmonary vasculature
F. Vanden Eynden, P. Segers, T. Bové, F. De Somer, B. El Oumeiri, G. Van Nooten
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- arteria pulmonalis fyziologie MeSH
- cévní rezistence fyziologie MeSH
- funkce pravé komory srdeční fyziologie MeSH
- plicní oběh fyziologie MeSH
- prasata MeSH
- pulzatilní průtok fyziologie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
In the pulmonary circulation, resistive and compliant properties overlap in the same vessels. Resistance varies nonlinearly with pressure and flow; this relationship is driven by the elastic properties of the vessels. Linehan et al. correlated the mean pulmonary arterial pressure and mean flow with resistance using an original equation incorporating the distensibility of the pulmonary arteries. The goal of this study was to validate this equation in an in vivo porcine model. In vivo measurements were acquired in 6 pigs. The distensibility coefficient (DC) was measured by placing piezo-electric crystals around the pulmonary artery (PA). In addition to experiments under pulsatile conditions, a right ventricular (RV) bypass system was used to induce a continuous pulmonary flow state. The Linehan et al. equation was then used to predict the pressure from the flow under continuous flow conditions. The diameter-derived DC was 2.4%/mmHg (+/-0.4%), whereas the surface area-based DC was 4.1 %/mmHg (+/-0.1%). An increase in continuous flow was associated with a constant decrease in resistance, which correlated with the diameter-based DC (r=-0.8407, p=0.044) and the surface area-based DC (r=-0.8986, p=0.028). In contrast to the Linehan et al. equation, our results showed constant or even decreasing pressure as flow increased. Using a model of continuous pulmonary flow induced by an RV assist system, pulmonary pressure could not be predicted based on the flow using the Linehan et al. equation. Measurements of distensibility based on the diameter of the PA were inversely correlated with the resistance.
IBiTech bioMMeda Ghent University Belgium
Laboratory of Experimental Cardiac Surgery Ghent University Hospital Belgium
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19042139
- 003
- CZ-PrNML
- 005
- 20191210084613.0
- 007
- ta
- 008
- 191205s2019 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933894 $2 doi
- 035 __
- $a (PubMed)30628823
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Vanden Eynden, F. $u Department of Cardiac Surgery, Université Libre de Bruxelles, Hopital Académique, Erasme, Brussels, Belgium; Laboratory of Experimental Cardiac Surgery, Ghent University Hospital, Belgium
- 245 10
- $a Use of a right ventricular continuous flow pump to validate the distensible model of the pulmonary vasculature / $c F. Vanden Eynden, P. Segers, T. Bové, F. De Somer, B. El Oumeiri, G. Van Nooten
- 504 __
- $a Literatura
- 520 9_
- $a In the pulmonary circulation, resistive and compliant properties overlap in the same vessels. Resistance varies nonlinearly with pressure and flow; this relationship is driven by the elastic properties of the vessels. Linehan et al. correlated the mean pulmonary arterial pressure and mean flow with resistance using an original equation incorporating the distensibility of the pulmonary arteries. The goal of this study was to validate this equation in an in vivo porcine model. In vivo measurements were acquired in 6 pigs. The distensibility coefficient (DC) was measured by placing piezo-electric crystals around the pulmonary artery (PA). In addition to experiments under pulsatile conditions, a right ventricular (RV) bypass system was used to induce a continuous pulmonary flow state. The Linehan et al. equation was then used to predict the pressure from the flow under continuous flow conditions. The diameter-derived DC was 2.4%/mmHg (+/-0.4%), whereas the surface area-based DC was 4.1 %/mmHg (+/-0.1%). An increase in continuous flow was associated with a constant decrease in resistance, which correlated with the diameter-based DC (r=-0.8407, p=0.044) and the surface area-based DC (r=-0.8986, p=0.028). In contrast to the Linehan et al. equation, our results showed constant or even decreasing pressure as flow increased. Using a model of continuous pulmonary flow induced by an RV assist system, pulmonary pressure could not be predicted based on the flow using the Linehan et al. equation. Measurements of distensibility based on the diameter of the PA were inversely correlated with the resistance.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a arteria pulmonalis $x fyziologie $7 D011651
- 650 _2
- $a plicní oběh $x fyziologie $7 D011652
- 650 _2
- $a pulzatilní průtok $x fyziologie $7 D011673
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a cévní rezistence $x fyziologie $7 D014655
- 650 _2
- $a funkce pravé komory srdeční $x fyziologie $7 D016278
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Segers, P. $u IBiTech-bioMMeda, Ghent University, Belgium
- 700 1_
- $a Bové, T. $u Laboratory of Experimental Cardiac Surgery, Ghent University Hospital, Belgium
- 700 1_
- $a De Somer, F. $u Laboratory of Experimental Cardiac Surgery, Ghent University Hospital, Belgium
- 700 1_
- $a El Oumeiri, B. $u Department of Cardiac Surgery, Université Libre de Bruxelles, Hopital Académique, Erasme, Brussels, Belgium
- 700 1_
- $a Van Nooten, G. $u Department of Cardiac Surgery, Université Libre de Bruxelles, Hopital Académique, Erasme, Brussels, Belgium; Laboratory of Experimental Cardiac Surgery, Ghent University Hospital, Belgium
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 68, č. 2 (2019), s. 233-243
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30628823 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y p $z 0
- 990 __
- $a 20191205 $b ABA008
- 991 __
- $a 20191206094924 $b ABA008
- 999 __
- $a ok $b bmc $g 1472708 $s 1080782
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 68 $c 2 $d 233-243 $e 20190110 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- LZP __
- $b NLK118 $a Pubmed-20191205