-
Je něco špatně v tomto záznamu ?
A flow-based platform hyphenated to on-line liquid chromatography for automatic leaching tests of chemical additives from microplastics into seawater
K. Fikarová, DJ. Cocovi-Solberg, M. Rosende, B. Horstkotte, H. Sklenářová, M. Miró,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
- MeSH
- automatizace MeSH
- chemické látky znečišťující vodu analýza MeSH
- chromatografie kapalinová metody MeSH
- kinetika MeSH
- mořská voda chemie MeSH
- plastické hmoty analýza MeSH
- vysokoúčinná kapalinová chromatografie MeSH
- Publikační typ
- časopisecké články MeSH
An automatic flow-based system as a front end to liquid chromatography (LC) for on-line dynamic leaching of microplastic materials (polyethylene of medium density and poly(vinyl chloride)) with incurred phthalates and bisphenol A is herein presented. The microplastic particles were packed in a metal column holder, through which seawater was pumped continuously by resorting to advanced flow methodology. Each milliliter of the leachable (bioaccessible) fraction of chemical additives was preconcentrated on-line using a 10 mm-long octadecyl monolithic silica column placed in the sampling loop of the injection valve of a HPLC system that served concomitantly for analyte uptake and removal of the seawater matrix. After loading of the leachate fraction, the LC valve was switched to the inject position and the analytes were eluted and separated by a monolithic column (Onyx C18HD 100 × 4.6 mm) using an optimized acetonitrile/water gradient with UV detection at 240 nm. The automatic flow method including dynamic flow-through extraction, on-line sorptive preconcentration, and matrix clean-up was synchronized with the HPLC separation, which lasted ca. 9 min. The only two currently available multi-component certified reference materials (CRM) of microplastics (CRM-PE002 and CRM-PVC001) were used for method development and validation. Out of the eight regulated phthalates contained in the two CRMs, only the 2 most polar species, namely, dimethyl phthalate and diethyl phthalate as well as bisphenol A, were leached significantly by the seawater in less than 2 h, with bioaccessibility percentages of 51-100%. The leaching profiles were monitored and modeled with a first-order kinetic equation so as to determine the rate constants for desorption in a risk assessment scenario. Intermediate precision values of bioaccessibility data for three batches of CRMs were for the suite of targeted compounds ≤22%. This work for the first time reports a fully automatic flow method with infinite sink capacity (i.e., using a surplus of extracting solution) for the target species able to mimic the leaching of additives from plastic debris across the water body in marine settings under worst-case extraction conditions.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19044688
- 003
- CZ-PrNML
- 005
- 20200115090714.0
- 007
- ta
- 008
- 200109s2019 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chroma.2019.06.041 $2 doi
- 035 __
- $a (PubMed)31280942
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Fikarová, Kateřina $u Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic; FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain.
- 245 12
- $a A flow-based platform hyphenated to on-line liquid chromatography for automatic leaching tests of chemical additives from microplastics into seawater / $c K. Fikarová, DJ. Cocovi-Solberg, M. Rosende, B. Horstkotte, H. Sklenářová, M. Miró,
- 520 9_
- $a An automatic flow-based system as a front end to liquid chromatography (LC) for on-line dynamic leaching of microplastic materials (polyethylene of medium density and poly(vinyl chloride)) with incurred phthalates and bisphenol A is herein presented. The microplastic particles were packed in a metal column holder, through which seawater was pumped continuously by resorting to advanced flow methodology. Each milliliter of the leachable (bioaccessible) fraction of chemical additives was preconcentrated on-line using a 10 mm-long octadecyl monolithic silica column placed in the sampling loop of the injection valve of a HPLC system that served concomitantly for analyte uptake and removal of the seawater matrix. After loading of the leachate fraction, the LC valve was switched to the inject position and the analytes were eluted and separated by a monolithic column (Onyx C18HD 100 × 4.6 mm) using an optimized acetonitrile/water gradient with UV detection at 240 nm. The automatic flow method including dynamic flow-through extraction, on-line sorptive preconcentration, and matrix clean-up was synchronized with the HPLC separation, which lasted ca. 9 min. The only two currently available multi-component certified reference materials (CRM) of microplastics (CRM-PE002 and CRM-PVC001) were used for method development and validation. Out of the eight regulated phthalates contained in the two CRMs, only the 2 most polar species, namely, dimethyl phthalate and diethyl phthalate as well as bisphenol A, were leached significantly by the seawater in less than 2 h, with bioaccessibility percentages of 51-100%. The leaching profiles were monitored and modeled with a first-order kinetic equation so as to determine the rate constants for desorption in a risk assessment scenario. Intermediate precision values of bioaccessibility data for three batches of CRMs were for the suite of targeted compounds ≤22%. This work for the first time reports a fully automatic flow method with infinite sink capacity (i.e., using a surplus of extracting solution) for the target species able to mimic the leaching of additives from plastic debris across the water body in marine settings under worst-case extraction conditions.
- 650 _2
- $a automatizace $7 D001331
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 _2
- $a chromatografie kapalinová $x metody $7 D002853
- 650 _2
- $a kinetika $7 D007700
- 650 _2
- $a plastické hmoty $x analýza $7 D010969
- 650 _2
- $a mořská voda $x chemie $7 D012623
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $7 D014874
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Cocovi-Solberg, David J $u FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain; University of Natural Resources and Life Sciences (BOKU), Muthgasse 18, 1190 Vienna, Austria.
- 700 1_
- $a Rosende, María $u FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain.
- 700 1_
- $a Horstkotte, Burkhard $u Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 700 1_
- $a Sklenářová, Hana $u Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
- 700 1_
- $a Miró, Manuel $u FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain. Electronic address: manuel.miro@uib.es.
- 773 0_
- $w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1602, č. - (2019), s. 160-167
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31280942 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200109 $b ABA008
- 991 __
- $a 20200115091047 $b ABA008
- 999 __
- $a ok $b bmc $g 1482957 $s 1083361
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 1602 $c - $d 160-167 $e 20190620 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
- LZP __
- $a Pubmed-20200109