• Je něco špatně v tomto záznamu ?

A flow-based platform hyphenated to on-line liquid chromatography for automatic leaching tests of chemical additives from microplastics into seawater

K. Fikarová, DJ. Cocovi-Solberg, M. Rosende, B. Horstkotte, H. Sklenářová, M. Miró,

. 2019 ; 1602 (-) : 160-167. [pub] 20190620

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19044688

An automatic flow-based system as a front end to liquid chromatography (LC) for on-line dynamic leaching of microplastic materials (polyethylene of medium density and poly(vinyl chloride)) with incurred phthalates and bisphenol A is herein presented. The microplastic particles were packed in a metal column holder, through which seawater was pumped continuously by resorting to advanced flow methodology. Each milliliter of the leachable (bioaccessible) fraction of chemical additives was preconcentrated on-line using a 10 mm-long octadecyl monolithic silica column placed in the sampling loop of the injection valve of a HPLC system that served concomitantly for analyte uptake and removal of the seawater matrix. After loading of the leachate fraction, the LC valve was switched to the inject position and the analytes were eluted and separated by a monolithic column (Onyx C18HD 100 × 4.6 mm) using an optimized acetonitrile/water gradient with UV detection at 240 nm. The automatic flow method including dynamic flow-through extraction, on-line sorptive preconcentration, and matrix clean-up was synchronized with the HPLC separation, which lasted ca. 9 min. The only two currently available multi-component certified reference materials (CRM) of microplastics (CRM-PE002 and CRM-PVC001) were used for method development and validation. Out of the eight regulated phthalates contained in the two CRMs, only the 2 most polar species, namely, dimethyl phthalate and diethyl phthalate as well as bisphenol A, were leached significantly by the seawater in less than 2 h, with bioaccessibility percentages of 51-100%. The leaching profiles were monitored and modeled with a first-order kinetic equation so as to determine the rate constants for desorption in a risk assessment scenario. Intermediate precision values of bioaccessibility data for three batches of CRMs were for the suite of targeted compounds ≤22%. This work for the first time reports a fully automatic flow method with infinite sink capacity (i.e., using a surplus of extracting solution) for the target species able to mimic the leaching of additives from plastic debris across the water body in marine settings under worst-case extraction conditions.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19044688
003      
CZ-PrNML
005      
20200115090714.0
007      
ta
008      
200109s2019 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2019.06.041 $2 doi
035    __
$a (PubMed)31280942
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Fikarová, Kateřina $u Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic; FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain.
245    12
$a A flow-based platform hyphenated to on-line liquid chromatography for automatic leaching tests of chemical additives from microplastics into seawater / $c K. Fikarová, DJ. Cocovi-Solberg, M. Rosende, B. Horstkotte, H. Sklenářová, M. Miró,
520    9_
$a An automatic flow-based system as a front end to liquid chromatography (LC) for on-line dynamic leaching of microplastic materials (polyethylene of medium density and poly(vinyl chloride)) with incurred phthalates and bisphenol A is herein presented. The microplastic particles were packed in a metal column holder, through which seawater was pumped continuously by resorting to advanced flow methodology. Each milliliter of the leachable (bioaccessible) fraction of chemical additives was preconcentrated on-line using a 10 mm-long octadecyl monolithic silica column placed in the sampling loop of the injection valve of a HPLC system that served concomitantly for analyte uptake and removal of the seawater matrix. After loading of the leachate fraction, the LC valve was switched to the inject position and the analytes were eluted and separated by a monolithic column (Onyx C18HD 100 × 4.6 mm) using an optimized acetonitrile/water gradient with UV detection at 240 nm. The automatic flow method including dynamic flow-through extraction, on-line sorptive preconcentration, and matrix clean-up was synchronized with the HPLC separation, which lasted ca. 9 min. The only two currently available multi-component certified reference materials (CRM) of microplastics (CRM-PE002 and CRM-PVC001) were used for method development and validation. Out of the eight regulated phthalates contained in the two CRMs, only the 2 most polar species, namely, dimethyl phthalate and diethyl phthalate as well as bisphenol A, were leached significantly by the seawater in less than 2 h, with bioaccessibility percentages of 51-100%. The leaching profiles were monitored and modeled with a first-order kinetic equation so as to determine the rate constants for desorption in a risk assessment scenario. Intermediate precision values of bioaccessibility data for three batches of CRMs were for the suite of targeted compounds ≤22%. This work for the first time reports a fully automatic flow method with infinite sink capacity (i.e., using a surplus of extracting solution) for the target species able to mimic the leaching of additives from plastic debris across the water body in marine settings under worst-case extraction conditions.
650    _2
$a automatizace $7 D001331
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a chromatografie kapalinová $x metody $7 D002853
650    _2
$a kinetika $7 D007700
650    _2
$a plastické hmoty $x analýza $7 D010969
650    _2
$a mořská voda $x chemie $7 D012623
650    _2
$a chemické látky znečišťující vodu $x analýza $7 D014874
655    _2
$a časopisecké články $7 D016428
700    1_
$a Cocovi-Solberg, David J $u FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain; University of Natural Resources and Life Sciences (BOKU), Muthgasse 18, 1190 Vienna, Austria.
700    1_
$a Rosende, María $u FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain.
700    1_
$a Horstkotte, Burkhard $u Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
700    1_
$a Sklenářová, Hana $u Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 05 Hradec Králové, Czech Republic.
700    1_
$a Miró, Manuel $u FI-TRACE Group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa km 7.5, E-07122 Palma, Spain. Electronic address: manuel.miro@uib.es.
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1602, č. - (2019), s. 160-167
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31280942 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200109 $b ABA008
991    __
$a 20200115091047 $b ABA008
999    __
$a ok $b bmc $g 1482957 $s 1083361
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 1602 $c - $d 160-167 $e 20190620 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20200109

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...