-
Je něco špatně v tomto záznamu ?
Presbyopic lens exchange (PRELEX) cataract surgery outcomes with implantation of a rotationally asymmetric refractive multifocal intraocular lens: femtosecond laser-assisted versus manual phacoemulsification
P. Žiak, J. Halička, P. Mojžiš, K. Kapitánová, J. Michal, DP. Piñero,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
Grantová podpora
RYC-2016-20471
Ministerio de Economía, Industria y Competitividad, Gobierno de España
NLK
ProQuest Central
od 2007-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2011-02-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2007-01-01 do Před 1 rokem
- MeSH
- citlivost na kontrast MeSH
- dospělí MeSH
- fakoemulzifikace * metody MeSH
- implantace nitrooční čočky * MeSH
- lidé středního věku MeSH
- lidé MeSH
- multifokální intraokulární čočky * MeSH
- refrakce oka * MeSH
- retrospektivní studie MeSH
- senioři MeSH
- zraková ostrost MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: To compare the visual and refractive outcomes obtained with the implantation of a rotationally asymmetric refractive multifocal IOL after femtosecond laser-assisted cataract surgery (FLACS) and conventional lens extraction (CLE). METHODS: A total of 78 eyes of 58 patients that had undergone conventional phacoemulsification (36 eyes, CLE group) or FLACS (37 eyes, FLACS group) with the implantation of the toric multifocal IOL LU-313 MF30T (Oculentis, Germany) were enrolled in this retrospective study. Mean age was 57.0 years at the time of surgery, ranging from 44 to 69 years. Visual and refractive outcomes were evaluated during a 12-month follow-up. Likewise, contrast sensitivity was assessed at the end of the follow-up. RESULTS: Significant improvements were observed in both groups in uncorrected distance (UDVA) and near visual acuity (UNVA) at 1 month postoperatively (p < 0.001). Differences between groups in these parameters as well as in sphere and cylinder did not reach statistical significance during the whole follow-up (p ≥ 0.079), except for UNVA only at 12 months postoperatively (p = 0.018). Concerning corrected near visual acuity, only significant differences between groups were found preoperatively (p = 0.020). Furthermore, only a minimal but significant difference between groups was found at 12 months postoperatively in contrast sensitivity for the spatial frequency of 18 cycles/° (p = 0.029). CONCLUSIONS: The rotationally asymmetric toric multifocal IOL LU-313 MF 30T provides good visual rehabilitation for near and distance vision after presbyopic lens extraction in eyes with preexisting astigmatism, independently whether the cataract surgery is performed with the FLACS or conventional technique.
Department of Physiology Jessenius Faculty of Medicine Comenius University Martin Slovakia
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20006282
- 003
- CZ-PrNML
- 005
- 20200526085322.0
- 007
- ta
- 008
- 200511s2019 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10792-019-01135-3 $2 doi
- 035 __
- $a (PubMed)31168677
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Žiak, Peter $u Eye Clinic, Jessenius Faculty of Medicine, Comenius University in Bratislava, Kollárova 2, 03659, Martin, Slovakia. 1ziakpeter@gmail.com. UVEA MEDIKLINIK, s.r.o, Martin, Slovakia. 1ziakpeter@gmail.com.
- 245 10
- $a Presbyopic lens exchange (PRELEX) cataract surgery outcomes with implantation of a rotationally asymmetric refractive multifocal intraocular lens: femtosecond laser-assisted versus manual phacoemulsification / $c P. Žiak, J. Halička, P. Mojžiš, K. Kapitánová, J. Michal, DP. Piñero,
- 520 9_
- $a PURPOSE: To compare the visual and refractive outcomes obtained with the implantation of a rotationally asymmetric refractive multifocal IOL after femtosecond laser-assisted cataract surgery (FLACS) and conventional lens extraction (CLE). METHODS: A total of 78 eyes of 58 patients that had undergone conventional phacoemulsification (36 eyes, CLE group) or FLACS (37 eyes, FLACS group) with the implantation of the toric multifocal IOL LU-313 MF30T (Oculentis, Germany) were enrolled in this retrospective study. Mean age was 57.0 years at the time of surgery, ranging from 44 to 69 years. Visual and refractive outcomes were evaluated during a 12-month follow-up. Likewise, contrast sensitivity was assessed at the end of the follow-up. RESULTS: Significant improvements were observed in both groups in uncorrected distance (UDVA) and near visual acuity (UNVA) at 1 month postoperatively (p < 0.001). Differences between groups in these parameters as well as in sphere and cylinder did not reach statistical significance during the whole follow-up (p ≥ 0.079), except for UNVA only at 12 months postoperatively (p = 0.018). Concerning corrected near visual acuity, only significant differences between groups were found preoperatively (p = 0.020). Furthermore, only a minimal but significant difference between groups was found at 12 months postoperatively in contrast sensitivity for the spatial frequency of 18 cycles/° (p = 0.029). CONCLUSIONS: The rotationally asymmetric toric multifocal IOL LU-313 MF 30T provides good visual rehabilitation for near and distance vision after presbyopic lens extraction in eyes with preexisting astigmatism, independently whether the cataract surgery is performed with the FLACS or conventional technique.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a citlivost na kontrast $7 D015350
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a implantace nitrooční čočky $7 D019654
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 12
- $a multifokální intraokulární čočky $7 D000075542
- 650 12
- $a fakoemulzifikace $x metody $7 D018918
- 650 12
- $a refrakce oka $7 D012029
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a zraková ostrost $7 D014792
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Halička, Juraj $u Eye Clinic, Jessenius Faculty of Medicine, Comenius University in Bratislava, Kollárova 2, 03659, Martin, Slovakia. UVEA MEDIKLINIK, s.r.o, Martin, Slovakia.
- 700 1_
- $a Mojžiš, Peter $u Premium Clinic, Teplice, Czech Republic.
- 700 1_
- $a Kapitánová, Karolína $u UVEA MEDIKLINIK, s.r.o, Martin, Slovakia.
- 700 1_
- $a Michal, Javorka $u Department of Physiology, Jessenius Faculty of Medicine, Comenius University, Martin, Slovakia.
- 700 1_
- $a Piñero, David P $u Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig s/n, 03016, San Vicente del Raspeig, Alicante, Spain. david.pinyero@ua.es.
- 773 0_
- $w MED00002383 $t International ophthalmology $x 1573-2630 $g Roč. 39, č. 12 (2019), s. 2875-2882
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31168677 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200511 $b ABA008
- 991 __
- $a 20200526085319 $b ABA008
- 999 __
- $a ok $b bmc $g 1525140 $s 1096338
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 39 $c 12 $d 2875-2882 $e 20190605 $i 1573-2630 $m International ophthalmology $n Int Ophthalmol $x MED00002383
- GRA __
- $a RYC-2016-20471 $p Ministerio de Economía, Industria y Competitividad, Gobierno de España
- LZP __
- $a Pubmed-20200511