Induction of fat apoptosis by a non-thermal device: Mechanism of action of non-invasive high-intensity electromagnetic technology in a porcine model

RA. Weiss, J. Bernardy,

. 2019 ; 51 (1) : 47-53. [pub] 20181214

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc20006688

OBJECTIVES: While controlled thermal changes in subcutaneous tissue have been used to trigger apoptosis of fat cells and have been proven clinically efficacious, another mechanism of electromagnetic stress suggests that fat apoptosis could be achieved by a non-thermal manner as well. This animal model study investigates the use of a non-invasive high-intensity magnetic field device to induce apoptosis in fat cells. METHODS: Yorkshire pigs (N = 2) received one treatment (30 minutes) in the abdominal area using a High-Intensity Focused Electromagnetic (HIFEM) device. Punch biopsy samples of fat tissue and blood samples were collected at the baseline, 1 and 8 hours after the treatment. Biopsy samples were sectioned and evaluated for the levels of an apoptotic index (AI) by the TUNEL method. Statistical significance was examined using the rANOVA and Tukey's test (α 5%). Biopsy samples were also assessed for molecular biomarkers. Blood samples were evaluated to determine changes related to fat and muscle metabolism. Free fatty acids (FFA), triacylglycerol (TG), glycerol and glucose (Glu) were used as the main biomarkers of fat metabolism. Creatinine, creatinine kinase (CK), lactate dehydrogenase (LDH) and interleukin 6 (IL6) served as the main biomarkers to evaluate muscle metabolism. RESULTS: In treated pigs, a statistically significant increase in the apoptotic index (AI) (P = 1.17E-4) was observed. A significant difference was found between AI at baseline (AI = 18.75%) and 8-hours post-treatment (AI = 35.95%). Serum levels of fat and muscle metabolism indicated trends (FFA -0.32 mmol · l-1 , -28.1%; TG -0.24 mmol · l-1 , -51.8%; Glycerol -5.68 mg · l-1 , -54.8%; CK +67.58 μkat · l-1 , +227.8%; LDH +4.9 μkat · l-1 ,+35.4%) suggesting that both adipose and muscle tissue were affected by HIFEM treatment. No adverse events were noted to skin and surrounding tissue. CONCLUSIONS: Application of a high-intensity electromagnetic field in a porcine model results in adipocyte apoptosis. The analysis of serum levels suggests that HIFEM treatment influences fat and muscle metabolism. Lasers Surg. Med. 51:47-53, 2019. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20006688
003      
CZ-PrNML
005      
20200520155629.0
007      
ta
008      
200511s2019 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1002/lsm.23039 $2 doi
035    __
$a (PubMed)30549290
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Weiss, Robert A $u Maryland Laser Skin, & Vein Institute, Hunt Valley, Maryland.
245    10
$a Induction of fat apoptosis by a non-thermal device: Mechanism of action of non-invasive high-intensity electromagnetic technology in a porcine model / $c RA. Weiss, J. Bernardy,
520    9_
$a OBJECTIVES: While controlled thermal changes in subcutaneous tissue have been used to trigger apoptosis of fat cells and have been proven clinically efficacious, another mechanism of electromagnetic stress suggests that fat apoptosis could be achieved by a non-thermal manner as well. This animal model study investigates the use of a non-invasive high-intensity magnetic field device to induce apoptosis in fat cells. METHODS: Yorkshire pigs (N = 2) received one treatment (30 minutes) in the abdominal area using a High-Intensity Focused Electromagnetic (HIFEM) device. Punch biopsy samples of fat tissue and blood samples were collected at the baseline, 1 and 8 hours after the treatment. Biopsy samples were sectioned and evaluated for the levels of an apoptotic index (AI) by the TUNEL method. Statistical significance was examined using the rANOVA and Tukey's test (α 5%). Biopsy samples were also assessed for molecular biomarkers. Blood samples were evaluated to determine changes related to fat and muscle metabolism. Free fatty acids (FFA), triacylglycerol (TG), glycerol and glucose (Glu) were used as the main biomarkers of fat metabolism. Creatinine, creatinine kinase (CK), lactate dehydrogenase (LDH) and interleukin 6 (IL6) served as the main biomarkers to evaluate muscle metabolism. RESULTS: In treated pigs, a statistically significant increase in the apoptotic index (AI) (P = 1.17E-4) was observed. A significant difference was found between AI at baseline (AI = 18.75%) and 8-hours post-treatment (AI = 35.95%). Serum levels of fat and muscle metabolism indicated trends (FFA -0.32 mmol · l-1 , -28.1%; TG -0.24 mmol · l-1 , -51.8%; Glycerol -5.68 mg · l-1 , -54.8%; CK +67.58 μkat · l-1 , +227.8%; LDH +4.9 μkat · l-1 ,+35.4%) suggesting that both adipose and muscle tissue were affected by HIFEM treatment. No adverse events were noted to skin and surrounding tissue. CONCLUSIONS: Application of a high-intensity electromagnetic field in a porcine model results in adipocyte apoptosis. The analysis of serum levels suggests that HIFEM treatment influences fat and muscle metabolism. Lasers Surg. Med. 51:47-53, 2019. © 2018 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.
650    _2
$a břišní tuk $x účinky záření $7 D050153
650    _2
$a zvířata $7 D000818
650    _2
$a apoptóza $x účinky záření $7 D017209
650    _2
$a biologické markery $x krev $7 D015415
650    _2
$a biopsie $7 D001706
650    _2
$a koncové značení zlomů DNA in situ $7 D020287
650    _2
$a magnetoterapie $x metody $7 D055909
650    _2
$a prasata $7 D013552
655    _2
$a časopisecké články $7 D016428
700    1_
$a Bernardy, Jan $u Veterinary Research Institute, Brno, Czech Republic.
773    0_
$w MED00010166 $t Lasers in surgery and medicine $x 1096-9101 $g Roč. 51, č. 1 (2019), s. 47-53
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30549290 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200511 $b ABA008
991    __
$a 20200520155628 $b ABA008
999    __
$a ok $b bmc $g 1525546 $s 1096744
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 51 $c 1 $d 47-53 $e 20181214 $i 1096-9101 $m Lasers in surgery and medicine $n Lasers Surg Med $x MED00010166
LZP    __
$a Pubmed-20200511

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...