Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Two Reliable Methodical Approaches for Non-Invasive RHD Genotyping of a Fetus from Maternal Plasma

J. Bohmova, M. Lubusky, I. Holuskova, M. Studnickova, R. Kratochvilova, E. Krejcirikova, V. Durdova, T. Kratochvilova, L. Dusek, M. Prochazka, R. Vodicka,

. 2020 ; 10 (8) : . [pub] 20200805

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc20021858

Grantová podpora
MH CZ - DRO (FNOL, 00098892) 2020 Ministry of Health of the Czech Republic

Noninvasive fetal RHD genotyping is an important tool for predicting RhD incompatibility between a pregnant woman and a fetus. This study aimed to assess a methodological approach other than the commonly used one for noninvasive fetal RHD genotyping on a representative set of RhD-negative pregnant women. The methodology must be accurate, reliable, and broadly available for implementation into routine clinical practice. A total of 337 RhD-negative pregnant women from the Czech Republic region were tested in this study. The fetal RHD genotype was assessed using two methods: real-time PCR and endpoint quantitative fluorescent (QF) PCR. We used exon-7-specific primers from the RHD gene, along with internal controls. Plasma samples were analyzed and measured in four/two parallel reactions to determine the accuracy of the RHD genotyping. The RHD genotype was verified using DNA analysis from a newborn buccal swab. Both methods showed an excellent ability to predict the RHD genotype. Real-time PCR achieved its greatest accuracy of 98.6% (97.1% sensitivity and 100% specificity (95% CI)) if all four PCRs were positive/negative. The QF PCR method also achieved its greatest accuracy of 99.4% (100% sensitivity and 98.6% specificity (95% CI)) if all the measurements were positive/negative. Both real-time PCR and QF PCR were reliable methods for precisely assessing the fetal RHD allele from the plasma of RhD-negative pregnant women.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20021858
003      
CZ-PrNML
005      
20201204093137.0
007      
ta
008      
201125s2020 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/diagnostics10080564 $2 doi
035    __
$a (PubMed)32764529
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Bohmova, Jana $u Department of Medical Genetics, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
245    10
$a Two Reliable Methodical Approaches for Non-Invasive RHD Genotyping of a Fetus from Maternal Plasma / $c J. Bohmova, M. Lubusky, I. Holuskova, M. Studnickova, R. Kratochvilova, E. Krejcirikova, V. Durdova, T. Kratochvilova, L. Dusek, M. Prochazka, R. Vodicka,
520    9_
$a Noninvasive fetal RHD genotyping is an important tool for predicting RhD incompatibility between a pregnant woman and a fetus. This study aimed to assess a methodological approach other than the commonly used one for noninvasive fetal RHD genotyping on a representative set of RhD-negative pregnant women. The methodology must be accurate, reliable, and broadly available for implementation into routine clinical practice. A total of 337 RhD-negative pregnant women from the Czech Republic region were tested in this study. The fetal RHD genotype was assessed using two methods: real-time PCR and endpoint quantitative fluorescent (QF) PCR. We used exon-7-specific primers from the RHD gene, along with internal controls. Plasma samples were analyzed and measured in four/two parallel reactions to determine the accuracy of the RHD genotyping. The RHD genotype was verified using DNA analysis from a newborn buccal swab. Both methods showed an excellent ability to predict the RHD genotype. Real-time PCR achieved its greatest accuracy of 98.6% (97.1% sensitivity and 100% specificity (95% CI)) if all four PCRs were positive/negative. The QF PCR method also achieved its greatest accuracy of 99.4% (100% sensitivity and 98.6% specificity (95% CI)) if all the measurements were positive/negative. Both real-time PCR and QF PCR were reliable methods for precisely assessing the fetal RHD allele from the plasma of RhD-negative pregnant women.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Lubusky, Marek $u Department of Obstetrics and Gynecology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Holuskova, Iva $u Department of Blood Transfusion, University Hospital and Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Studnickova, Martina $u Department of Obstetrics and Gynecology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Kratochvilova, Romana $u Department of Medical Genetics, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Krejcirikova, Eva $u Department of Medical Genetics, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Durdova, Veronika $u Department of Obstetrics and Gynecology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Kratochvilova, Tereza $u Department of Obstetrics and Gynecology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Dusek, Ladislav $u Institute of Biostatistics and Analyses, Masaryk University, 625 00 Brno, Czech Republic.
700    1_
$a Prochazka, Martin $u Department of Medical Genetics, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
700    1_
$a Vodicka, Radek $u Department of Medical Genetics, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, 775 20 Olomouc, Czech Republic.
773    0_
$w MED00195450 $t Diagnostics (Basel, Switzerland) $x 2075-4418 $g Roč. 10, č. 8 (2020)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32764529 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201204093135 $b ABA008
999    __
$a ind $b bmc $g 1591567 $s 1112530
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 10 $c 8 $e 20200805 $i 2075-4418 $m Diagnostics $n Diagnostics $x MED00195450
GRA    __
$a MH CZ - DRO (FNOL, 00098892) 2020 $p Ministry of Health of the Czech Republic
LZP    __
$a Pubmed-20201125

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...