Something wrong with this record ?
Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
A. Le Gall, F. Vallée, K. Pushparajah, T. Hussain, A. Mebazaa, D. Chapelle, É. Gayat, R. Chabiniok,
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't
Grant support
WT 203148/Z/16/Z
Wellcome Trust - United Kingdom
NLK
Directory of Open Access Journals
from 2006
Free Medical Journals
from 2006
Public Library of Science (PLoS)
from 2006
PubMed Central
from 2006
Europe PubMed Central
from 2006
ProQuest Central
from 2006-12-01
Open Access Digital Library
from 2006-01-01
Open Access Digital Library
from 2006-10-01
Open Access Digital Library
from 2006-01-01
Medline Complete (EBSCOhost)
from 2008-01-01
Nursing & Allied Health Database (ProQuest)
from 2006-12-01
Health & Medicine (ProQuest)
from 2006-12-01
Public Health Database (ProQuest)
from 2006-12-01
ROAD: Directory of Open Access Scholarly Resources
from 2006
- MeSH
- Algorithms MeSH
- Arterial Pressure physiology MeSH
- Biomechanical Phenomena MeSH
- Anesthesia, General methods MeSH
- Hemodynamic Monitoring methods MeSH
- Hypotension drug therapy physiopathology MeSH
- Blood Pressure MeSH
- Middle Aged MeSH
- Humans MeSH
- Cardiac Output physiology MeSH
- Models, Cardiovascular * MeSH
- Norepinephrine administration & dosage MeSH
- Proof of Concept Study MeSH
- Prospective Studies MeSH
- Stroke Volume physiology MeSH
- Vasoconstrictor Agents administration & dosage MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (Vva), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased Vva (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, Vva increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20025011
- 003
- CZ-PrNML
- 005
- 20201222155011.0
- 007
- ta
- 008
- 201125s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1371/journal.pone.0232830 $2 doi
- 035 __
- $a (PubMed)32407353
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Le Gall, Arthur $u Inria, Paris, France. LMS, École Polytechnique, CNRS, Institut Polytechnique de Paris, Paris, France. Anesthesiology and Intensive Care Department, Lariboisière - Saint Louis - Fernand Widal University Hospitals, Paris, France. INSERM, Paris, France.
- 245 10
- $a Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study / $c A. Le Gall, F. Vallée, K. Pushparajah, T. Hussain, A. Mebazaa, D. Chapelle, É. Gayat, R. Chabiniok,
- 520 9_
- $a During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (Vva), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased Vva (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, Vva increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology.
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a celková anestezie $x metody $7 D000768
- 650 _2
- $a arteriální tlak $x fyziologie $7 D062186
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a krevní tlak $7 D001794
- 650 _2
- $a minutový srdeční výdej $x fyziologie $7 D002302
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a hemodynamické monitorování $x metody $7 D000074743
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hypotenze $x farmakoterapie $x patofyziologie $7 D007022
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 12
- $a modely kardiovaskulární $7 D008955
- 650 _2
- $a noradrenalin $x aplikace a dávkování $7 D009638
- 650 _2
- $a ověření koncepční studie $7 D000075082
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a tepový objem $x fyziologie $7 D013318
- 650 _2
- $a vazokonstriktory $x aplikace a dávkování $7 D014662
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vallée, Fabrice $u Inria, Paris, France. LMS, École Polytechnique, CNRS, Institut Polytechnique de Paris, Paris, France. Anesthesiology and Intensive Care Department, Lariboisière - Saint Louis - Fernand Widal University Hospitals, Paris, France. INSERM, Paris, France.
- 700 1_
- $a Pushparajah, Kuberan $u School of Biomedical Engineering & Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom.
- 700 1_
- $a Hussain, Tarique $u Department of Pediatrics, Division of Pediatric Cardiology, UT Southwestern Medical Center, Dallas, TX, United States of America.
- 700 1_
- $a Mebazaa, Alexandre $u Anesthesiology and Intensive Care Department, Lariboisière - Saint Louis - Fernand Widal University Hospitals, Paris, France. INSERM, Paris, France.
- 700 1_
- $a Chapelle, Dominique $u Inria, Paris, France. LMS, École Polytechnique, CNRS, Institut Polytechnique de Paris, Paris, France.
- 700 1_
- $a Gayat, Étienne $u Anesthesiology and Intensive Care Department, Lariboisière - Saint Louis - Fernand Widal University Hospitals, Paris, France. INSERM, Paris, France.
- 700 1_
- $a Chabiniok, Radomír $u Inria, Paris, France. LMS, École Polytechnique, CNRS, Institut Polytechnique de Paris, Paris, France. School of Biomedical Engineering & Imaging Sciences, St Thomas' Hospital, King's College London, London, United Kingdom. Department of Mathematics, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
- 773 0_
- $w MED00180950 $t PloS one $x 1932-6203 $g Roč. 15, č. 5 (2020), s. e0232830
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32407353 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20201222155007 $b ABA008
- 999 __
- $a ok $b bmc $g 1599156 $s 1115697
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 15 $c 5 $d e0232830 $e 20200514 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
- GRA __
- $a WT 203148/Z/16/Z $p Wellcome Trust $2 United Kingdom
- LZP __
- $a Pubmed-20201125