SIMULATION OF THE RESPONSE OF A LaBr3(Ce) DETECTOR IN AN ATMOSPHERE CONTAMINATED WITH RADIONUCLIDES AFTER A NUCLEAR POWER PLANT ACCIDENT

T. Urban, P. Vágner,

. 2019 ; 186 (2-3) : 346-350. [pub] 2019Dec31

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc20025340

The aim of this paper is to investigate the possibility of using detectors based on LaBr3(Ce) scintillation crystal as part of gamma spectrometry systems for field use and possibly as part of a monitoring network around nuclear power plants, i.e. whether LaBr3(Ce) detectors can follow the classical scintillation detectors based on NaI (Tl). For this purpose, the Monte Carlo simulation of the IPROL-1 probe response was performed in the simplified geometry of the radionuclides-contaminated atmosphere. A study shows that a LaBr3(Ce)-based probe is usable for this purpose and results are at least comparable to those with a conventional NaI (Tl)-based probe.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20025340
003      
CZ-PrNML
005      
20201222153823.0
007      
ta
008      
201125s2019 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncz259 $2 doi
035    __
$a (PubMed)31836901
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Urban, Tomáš $u Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Břehová 7, 115 19 Prague, Czech Republic.
245    10
$a SIMULATION OF THE RESPONSE OF A LaBr3(Ce) DETECTOR IN AN ATMOSPHERE CONTAMINATED WITH RADIONUCLIDES AFTER A NUCLEAR POWER PLANT ACCIDENT / $c T. Urban, P. Vágner,
520    9_
$a The aim of this paper is to investigate the possibility of using detectors based on LaBr3(Ce) scintillation crystal as part of gamma spectrometry systems for field use and possibly as part of a monitoring network around nuclear power plants, i.e. whether LaBr3(Ce) detectors can follow the classical scintillation detectors based on NaI (Tl). For this purpose, the Monte Carlo simulation of the IPROL-1 probe response was performed in the simplified geometry of the radionuclides-contaminated atmosphere. A study shows that a LaBr3(Ce)-based probe is usable for this purpose and results are at least comparable to those with a conventional NaI (Tl)-based probe.
650    _2
$a radioaktivní látky znečišťující vzduch $x analýza $7 D000396
650    12
$a počítačová simulace $7 D003198
650    _2
$a havárie elektrárny Fukušima $7 D062406
650    _2
$a záření gama $7 D005720
650    _2
$a lidé $7 D006801
650    _2
$a metoda Monte Carlo $7 D009010
650    12
$a jaderné elektrárny $7 D055848
650    _2
$a dávka záření $7 D011829
650    _2
$a radiační expozice $x analýza $7 D000069079
650    _2
$a monitorování radiace $x přístrojové vybavení $x metody $7 D011834
655    _2
$a časopisecké články $7 D016428
700    1_
$a Vágner, Petr $u NUVIA a.s., Modřínová 1094,674 01 Třebíč, Czech Republic.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 186, č. 2-3 (2019), s. 346-350
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31836901 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222153819 $b ABA008
999    __
$a ok $b bmc $g 1599485 $s 1116026
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 186 $c 2-3 $d 346-350 $e 2019Dec31 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20201125

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...