Influence of the use of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution flows
Klara Fiedorova, Martin Augustynek, Marek Penhaker
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
- MeSH
- bezpečnost pacientů MeSH
- infuzní pumpy * škodlivé účinky MeSH
- lidé MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
The subject of the work was the experimental verification of the negative influence of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution dosing. The quality criterion for gravity sets was the accuracy of the flow versus the reference set by the volumetric infusion pump. The solution consisted of 14-hour measurements with two types of gravity sets, Intrafix® Primeline sets were used as universal sets and Standardline IS 103 gravity sets. The insulin pump flow rate was set at 300 ml/h and 50 ml/h, and the actual flow rate of the infusion solution was recorded every hour using a graduated cylinder. Used gravity sets were also processed by mechanical tests, unused sets were subjected to these tests and the obtained data were compared with each other. Experiments carried out showed that at the set flow rate of 300 ml/h, the flow error with the universal set was -3% and at a set flow rate of 50 ml/h the error was +2.3%. Flow accuracy using gravity sets was worse, a flow error of -7.2% was detected for a flow rate of 50 ml/h and a flow error of -7.7% was measured for 300 ml/h. The volumetric pump used declares a tolerated inaccuracy of ± 3% when used with standard infusion sets. Based on the data, it can be concluded that the replacement of set types has an influence on the dosage of infusion solutions.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20026257
- 003
- CZ-PrNML
- 005
- 20210304162414.0
- 007
- ta
- 008
- 201221s2020 xr d f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14311/CTJ.2020.1.04 $2 doi
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 0_
- $a Fiedorová, Klára $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB Technical University of Ostrava, Ostrava, Czech Republic $7 xx0255517
- 245 10
- $a Influence of the use of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution flows / $c Klara Fiedorova, Martin Augustynek, Marek Penhaker
- 520 9_
- $a The subject of the work was the experimental verification of the negative influence of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution dosing. The quality criterion for gravity sets was the accuracy of the flow versus the reference set by the volumetric infusion pump. The solution consisted of 14-hour measurements with two types of gravity sets, Intrafix® Primeline sets were used as universal sets and Standardline IS 103 gravity sets. The insulin pump flow rate was set at 300 ml/h and 50 ml/h, and the actual flow rate of the infusion solution was recorded every hour using a graduated cylinder. Used gravity sets were also processed by mechanical tests, unused sets were subjected to these tests and the obtained data were compared with each other. Experiments carried out showed that at the set flow rate of 300 ml/h, the flow error with the universal set was -3% and at a set flow rate of 50 ml/h the error was +2.3%. Flow accuracy using gravity sets was worse, a flow error of -7.2% was detected for a flow rate of 50 ml/h and a flow error of -7.7% was measured for 300 ml/h. The volumetric pump used declares a tolerated inaccuracy of ± 3% when used with standard infusion sets. Based on the data, it can be concluded that the replacement of set types has an influence on the dosage of infusion solutions.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a infuzní pumpy $x škodlivé účinky $7 D007260
- 650 _2
- $a bezpečnost pacientů $7 D061214
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Augustynek, Martin $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB Technical University of Ostrava, Ostrava, Czech Republic $7 ola2011639627
- 700 1_
- $a Penhaker, Marek, $u Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB Technical University of Ostrava, Ostrava, Czech Republic $d 1972- $7 mzk2004246505
- 773 0_
- $w MED00011033 $t Lékař a technika $x 0301-5491 $g Roč. 50, č. 1 (2020), s. 23-31
- 856 41
- $u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/5478/5818 $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y p $z 0
- 990 __
- $a 20201221 $b ABA008
- 991 __
- $a 20210304162411 $b ABA008
- 999 __
- $a ok $b bmc $g 1604910 $s 1116945
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 50 $c 1 $d 23-31 $i 0301-5491 $m Lékař a technika $x MED00011033 $y 124917
- LZP __
- $c NLK109 $d 20210304 $b NLK111 $a Meditorial-20201221