• Je něco špatně v tomto záznamu ?

Toward an automated workflow for the study of plasma protein-drug interactions based on capillary electrophoresis-frontal analysis combined with in-capillary mixing of interacting partners

L. Michalcová, H. Nevídalová, Z. Glatz,

. 2021 ; 1635 (-) : 461734. [pub] 20201119

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc20027548

Capillary electrophoresis-frontal analysis (CE-FA) together with mobility shift affinity CE is the most frequently used mode of affinity CE for a study of plasma protein-drug interactions, which is a substantial part of the early stage of drug discovery. Whereas in the classic CE-FA setup the sample is prepared by off-line mixing of the interaction partners in the sample vial outside the CE instrument and after a short incubation period loaded into the capillary and analysed, in this work a new methodological approach has been developed that combines CE-FA with the mixing of interacting partners directly inside the capillary. This combination gives rise to a fully automated and versatile methodology for the characterization of these binding interactions besides a substantial reduction in the amounts of sample compounds used. The minimization of possible experimental errors due to the full involving of sophisticated CE instrument in the injection procedure, mixing and separation instead of manual manipulation is another fundamental benefit. The in-capillary mixing is based on the transverse diffusion of laminar flow profile methodology introduced by Krylov et al. using its multi-zone injection modification presented by Řemínek at al.. Actually, after the method optimization, the alternate introduction of six plugs of drug and six plugs of bovine serum protein in BGE, each injected for 3 s at a pressure of -10 mbar (-1 kPa) into the capillary filled by BGE, was found to be the best injection procedure. The method repeatability calculated as RSDs of plateau highs of bovine serum albumin and propranolol as model sample compounds were better than 3.44 %. Its applicability was finally demonstrated on the determination of apparent binding parameters of bovine serum albumin for basic drugs propranolol and lidocaine and acid drug phenylbutazone. The values obtained by a new on-line CE-FA methodology are in agreement with values estimated by classic off-line CE-FA, as well as with literature data obtained using different techniques.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20027548
003      
CZ-PrNML
005      
20210114152049.0
007      
ta
008      
210105s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2020.461734 $2 doi
035    __
$a (PubMed)33264700
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Michalcová, Lenka $u Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
245    10
$a Toward an automated workflow for the study of plasma protein-drug interactions based on capillary electrophoresis-frontal analysis combined with in-capillary mixing of interacting partners / $c L. Michalcová, H. Nevídalová, Z. Glatz,
520    9_
$a Capillary electrophoresis-frontal analysis (CE-FA) together with mobility shift affinity CE is the most frequently used mode of affinity CE for a study of plasma protein-drug interactions, which is a substantial part of the early stage of drug discovery. Whereas in the classic CE-FA setup the sample is prepared by off-line mixing of the interaction partners in the sample vial outside the CE instrument and after a short incubation period loaded into the capillary and analysed, in this work a new methodological approach has been developed that combines CE-FA with the mixing of interacting partners directly inside the capillary. This combination gives rise to a fully automated and versatile methodology for the characterization of these binding interactions besides a substantial reduction in the amounts of sample compounds used. The minimization of possible experimental errors due to the full involving of sophisticated CE instrument in the injection procedure, mixing and separation instead of manual manipulation is another fundamental benefit. The in-capillary mixing is based on the transverse diffusion of laminar flow profile methodology introduced by Krylov et al. using its multi-zone injection modification presented by Řemínek at al.. Actually, after the method optimization, the alternate introduction of six plugs of drug and six plugs of bovine serum protein in BGE, each injected for 3 s at a pressure of -10 mbar (-1 kPa) into the capillary filled by BGE, was found to be the best injection procedure. The method repeatability calculated as RSDs of plateau highs of bovine serum albumin and propranolol as model sample compounds were better than 3.44 %. Its applicability was finally demonstrated on the determination of apparent binding parameters of bovine serum albumin for basic drugs propranolol and lidocaine and acid drug phenylbutazone. The values obtained by a new on-line CE-FA methodology are in agreement with values estimated by classic off-line CE-FA, as well as with literature data obtained using different techniques.
650    _2
$a krevní proteiny $x chemie $x metabolismus $7 D001798
650    _2
$a farmaceutická chemie $x metody $7 D002626
650    _2
$a difuze $7 D004058
650    12
$a elektroforéza kapilární $7 D019075
650    _2
$a léčivé přípravky $x metabolismus $7 D004364
650    _2
$a propranolol $x chemie $x metabolismus $7 D011433
650    _2
$a sérový albumin hovězí $x chemie $x metabolismus $7 D012710
650    _2
$a průběh práce $7 D057188
655    _2
$a časopisecké články $7 D016428
700    1_
$a Nevídalová, Hana $u Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
700    1_
$a Glatz, Zdeněk $u Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic. Electronic address: glatz@chemi.muni.cz.
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1635, č. - (2021), s. 461734
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33264700 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20210105 $b ABA008
991    __
$a 20210114152048 $b ABA008
999    __
$a ok $b bmc $g 1607883 $s 1118728
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 1635 $c - $d 461734 $e 20201119 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20210105

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...