-
Something wrong with this record ?
A Randomized Comparison of Non-Channeled GlidescopeTM Titanium Versus Channeled KingVisionTM Videolaryngoscope for Orotracheal Intubation in Obese Patients with BMI > 35 kg·m-2
T. Brozek, J. Bruthans, M. Porizka, J. Blaha, J. Ulrichova, P. Michalek,
Language English Country Switzerland
Document type Journal Article
Grant support
MZCZ-DRO-VFN64165
Ministerstvo Zdravotnictví Ceské Republiky
NLK
Directory of Open Access Journals
from 2011
PubMed Central
from 2011
Europe PubMed Central
from 2011
ProQuest Central
from 2011-01-01
Open Access Digital Library
from 2011-01-01
Open Access Digital Library
from 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2011
- Publication type
- Journal Article MeSH
Videolaryngoscopes may improve intubating conditions in obese patients. A total of 110 patients with a body mass index > 35 kg∙m-2 were prospectively randomized to tracheal intubation using non-channeled Glidescope Titanium or channeled King Vision videolaryngoscope. The primary outcome was the time to tracheal intubation. Secondary outcomes included: total success rate, number of attempts, the quality of visualization, peri-procedural and post-proceduralcomplications. Time to the first effective breath was shorter with the King Vision (median; 95% CI)-36; 34-39 s vs. 42; 40-50 in the Glidescope group (p = 0.007). The total success rate was higher in the Glidescope group-100% vs. 89.1% (p = 0.03). There was a higher incidence of moderate and difficult laryngoscopy in the King Vision group. No difference was recorded in first attempt success rates, total number of attempts, use of additional maneuvers, intraoperative trauma, or any significant decrease in SpO2 during intubation. No serious complications were noted and the incidence of postoperative complaints was without difference. Although tracheal intubation with King Vision showed shorter time to the first breath, total success was higher in the Glidescope group, and all but one patients where intubation failed with the KingVision were subsequently intubated with the Glidescope.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21001655
- 003
- CZ-PrNML
- 005
- 20210126092808.0
- 007
- ta
- 008
- 210105s2020 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/diagnostics10121024 $2 doi
- 035 __
- $a (PubMed)33260374
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Brozek, Tomas $u Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, 128 00 Prague, Czech Republic. Medical Faculty, Masaryk University, 625 00 Brno, Czech Republic.
- 245 12
- $a A Randomized Comparison of Non-Channeled GlidescopeTM Titanium Versus Channeled KingVisionTM Videolaryngoscope for Orotracheal Intubation in Obese Patients with BMI > 35 kg·m-2. / $c T. Brozek, J. Bruthans, M. Porizka, J. Blaha, J. Ulrichova, P. Michalek,
- 520 9_
- $a Videolaryngoscopes may improve intubating conditions in obese patients. A total of 110 patients with a body mass index > 35 kg∙m-2 were prospectively randomized to tracheal intubation using non-channeled Glidescope Titanium or channeled King Vision videolaryngoscope. The primary outcome was the time to tracheal intubation. Secondary outcomes included: total success rate, number of attempts, the quality of visualization, peri-procedural and post-proceduralcomplications. Time to the first effective breath was shorter with the King Vision (median; 95% CI)-36; 34-39 s vs. 42; 40-50 in the Glidescope group (p = 0.007). The total success rate was higher in the Glidescope group-100% vs. 89.1% (p = 0.03). There was a higher incidence of moderate and difficult laryngoscopy in the King Vision group. No difference was recorded in first attempt success rates, total number of attempts, use of additional maneuvers, intraoperative trauma, or any significant decrease in SpO2 during intubation. No serious complications were noted and the incidence of postoperative complaints was without difference. Although tracheal intubation with King Vision showed shorter time to the first breath, total success was higher in the Glidescope group, and all but one patients where intubation failed with the KingVision were subsequently intubated with the Glidescope.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Bruthans, Jan $u Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, 128 00 Prague, Czech Republic.
- 700 1_
- $a Porizka, Michal $u Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, 128 00 Prague, Czech Republic.
- 700 1_
- $a Blaha, Jan $u Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, 128 00 Prague, Czech Republic.
- 700 1_
- $a Ulrichova, Jitka $u Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, 128 00 Prague, Czech Republic.
- 700 1_
- $a Michalek, Pavel $u Department of Anaesthesiology and Intensive Medicine, General University Hospital and First Medical Faculty of the Charles University, 128 00 Prague, Czech Republic. Department of Anaesthesia, Antrim Area Hospital, Antrim BT41 2RL, UK.
- 773 0_
- $w MED00195450 $t Diagnostics (Basel, Switzerland) $x 2075-4418 $g Roč. 10, č. 12 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33260374 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210126092803 $b ABA008
- 999 __
- $a ind $b bmc $g 1613965 $s 1121939
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 10 $c 12 $e 20201129 $i 2075-4418 $m Diagnostics $n Diagnostics $x MED00195450
- GRA __
- $a MZCZ-DRO-VFN64165 $p Ministerstvo Zdravotnictví Ceské Republiky
- LZP __
- $a Pubmed-20210105