-
Something wrong with this record ?
Paper-based molecularly imprinted-interpenetrating polymer network for on-spot collection and microextraction of dried blood spots for capillary electrophoresis determination of carbamazepine
N. Nuchtavorn, M. Dvořák, P. Kubáň
Language English Country Germany
Document type Journal Article
Grant support
RVO:68081715
Akademie Věd České Republiky
18-13135S
Grantová Agentura České Republiky
NLK
ProQuest Central
from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 2011-01-01 to 1 year ago
- MeSH
- Anticonvulsants blood isolation & purification MeSH
- Electrophoresis, Capillary methods MeSH
- Carbamazepine blood isolation & purification MeSH
- Humans MeSH
- Solid Phase Microextraction methods MeSH
- Molecularly Imprinted Polymers chemistry MeSH
- Drug Monitoring MeSH
- Blood Specimen Collection methods MeSH
- Paper MeSH
- Tandem Mass Spectrometry MeSH
- Dried Blood Spot Testing methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
Carbamazepine is an antiepileptic drug with a narrow therapeutic index, which requires an efficient method for blood level monitoring. Finger-prick dried blood spot (DBS) collection is an alternative microsampling technique, which is less invasive than conventional venipuncture. Paper-based molecularly imprinted-interpenetrating polymer networks (MI-IPN) were developed as blood collection devices, which allowed for selective on-spot microextraction of carbamazepine from DBS. A hybrid of homogeneous polystyrene and silica gel polymer was synthesized and coated on a Whatman® Grade 1 filter paper. Proteins and other interferences in the blood samples were eliminated by using the MI-IPN collection devices, and the resulting DBS extracts were suitable for direct injection into the capillary electrophoretic instrument. The lower limit of quantitation of 4 μg/mL in capillary blood was achieved by the sweeping-micellar electrokinetic chromatography method using a KCl-containing matrix, which was sufficient for the therapeutic drug monitoring purposes. Method accuracies were in the range of 88.4 ± 4.5% to 94.5 ± 2.7% with RSD values ≤ 5.1%. The developed paper-based MI-IPN provided superior extraction efficiencies (92.2 ± 2.5%) in comparison with commercially available DBS collection cards, i.e., Whatman® 903 protein saver card (59.8 ± 2.8%) and GenCollect™ 2.0 card (47.2 ± 1.4%). The paper-based MI-IPN devices for DBS collection and on-spot extraction were characterized by simple fabrication, low costs, disposability, and reduction in sample preparation steps, and their further developments might open new perspectives in clinical applications, such as in therapeutic drug monitoring. Graphical abstract.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21012620
- 003
- CZ-PrNML
- 005
- 20210507101549.0
- 007
- ta
- 008
- 210420s2020 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-020-02523-w $2 doi
- 035 __
- $a (PubMed)32103309
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Nuchtavorn, Nantana $u Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Mahidol University, 447 Sri-Ayudhaya Rd., Rajathevee, Bangkok, 10400, Thailand
- 245 10
- $a Paper-based molecularly imprinted-interpenetrating polymer network for on-spot collection and microextraction of dried blood spots for capillary electrophoresis determination of carbamazepine / $c N. Nuchtavorn, M. Dvořák, P. Kubáň
- 520 9_
- $a Carbamazepine is an antiepileptic drug with a narrow therapeutic index, which requires an efficient method for blood level monitoring. Finger-prick dried blood spot (DBS) collection is an alternative microsampling technique, which is less invasive than conventional venipuncture. Paper-based molecularly imprinted-interpenetrating polymer networks (MI-IPN) were developed as blood collection devices, which allowed for selective on-spot microextraction of carbamazepine from DBS. A hybrid of homogeneous polystyrene and silica gel polymer was synthesized and coated on a Whatman® Grade 1 filter paper. Proteins and other interferences in the blood samples were eliminated by using the MI-IPN collection devices, and the resulting DBS extracts were suitable for direct injection into the capillary electrophoretic instrument. The lower limit of quantitation of 4 μg/mL in capillary blood was achieved by the sweeping-micellar electrokinetic chromatography method using a KCl-containing matrix, which was sufficient for the therapeutic drug monitoring purposes. Method accuracies were in the range of 88.4 ± 4.5% to 94.5 ± 2.7% with RSD values ≤ 5.1%. The developed paper-based MI-IPN provided superior extraction efficiencies (92.2 ± 2.5%) in comparison with commercially available DBS collection cards, i.e., Whatman® 903 protein saver card (59.8 ± 2.8%) and GenCollect™ 2.0 card (47.2 ± 1.4%). The paper-based MI-IPN devices for DBS collection and on-spot extraction were characterized by simple fabrication, low costs, disposability, and reduction in sample preparation steps, and their further developments might open new perspectives in clinical applications, such as in therapeutic drug monitoring. Graphical abstract.
- 650 _2
- $a antikonvulziva $x krev $x izolace a purifikace $7 D000927
- 650 _2
- $a odběr vzorku krve $x metody $7 D001800
- 650 _2
- $a karbamazepin $x krev $x izolace a purifikace $7 D002220
- 650 _2
- $a test suché kapky krve $x metody $7 D059788
- 650 _2
- $a monitorování léčiv $7 D016903
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a molekulárně imprintované polymery $x chemie $7 D000082582
- 650 _2
- $a papír $7 D010209
- 650 _2
- $a mikroextrakce na pevné fázi $x metody $7 D052617
- 650 _2
- $a tandemová hmotnostní spektrometrie $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Dvořák, Miloš $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00, Brno, Czech Republic
- 700 1_
- $a Kubáň, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00, Brno, Czech Republic. kuban@iach.cz
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 412, č. 12 (2020), s. 2721-2730
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32103309 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210420 $b ABA008
- 991 __
- $a 20210507101549 $b ABA008
- 999 __
- $a ok $b bmc $g 1650893 $s 1132999
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 412 $c 12 $d 2721-2730 $e 20200227 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- GRA __
- $a RVO:68081715 $p Akademie Věd České Republiky
- GRA __
- $a 18-13135S $p Grantová Agentura České Republiky
- LZP __
- $a Pubmed-20210420