-
Je něco špatně v tomto záznamu ?
Surgical conditions with rocuronium versus suxamethonium in cesarean section: a randomized trial
J. Bláha, P. Nosková, K. Hlinecká, V. Krakovská, V. Fundová, T. Bartošová, P. Michálek, M. Stříteský
Jazyk angličtina Země Nizozemsko
Typ dokumentu srovnávací studie, časopisecké články, randomizované kontrolované studie
- MeSH
- časové faktory MeSH
- císařský řez * MeSH
- dospělí MeSH
- dvojitá slepá metoda MeSH
- lidé MeSH
- prospektivní studie MeSH
- rokuronium farmakologie MeSH
- sukcinylcholin farmakologie MeSH
- těhotenství MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
BACKGROUND: Onset times and conditions for intubation after rocuronium versus suxamethonium at cesarean section have been evaluated, but no study thus far has examined the influence of these neuromuscular blocking drugs on the surgical conditions or their effect on the duration of surgery and the ease of fetal delivery. We aimed to compare the surgical conditions for delivery in parturients who received deep neuromuscular block with rocuronium with those who had induction with suxamethonium. METHODS: Ninety patients undergoing cesarean section under general anesthesia were randomized to receive either rocuronium 0.6 mg/kg or suxamethonium 1 mg/kg for tracheal intubation and delivery. Times to delivery and the quality of surgical conditions, using a five-point Surgical Rating Scale for Delivery (SRSD) ranging from 1 (poor) to 5 (excellent), were evaluated. RESULTS: The median SRSD (range) was found to be significantly better in the rocuronium group [4 (3-5) points vs 3 (2-4) points with suxamethonium (P <0.001)]. Whereas the mean (SD) induction-to-intubation interval was longer with rocuronium [106 (34) s vs 68 (32) s with suxamethonium (95% CI of the difference 24 to 52 s, P <0.001)], the incision-to-delivery interval was shorter in the rocuronium group [147 (68) s vs 196 (51) s with suxamethonium (95% CI of the difference -75 to -24 s, P <0.001)]. The mean induction-to-delivery intervals were similar [268 (73) s vs 276 (63) s, respectively]. CONCLUSIONS: Whereas the induction-to-delivery intervals were comparable, we found rocuronium superior to suxamethonium in allowing better surgical conditions for fetal delivery, which enabled an easier delivery and a shorter incision-to-delivery interval.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21012885
- 003
- CZ-PrNML
- 005
- 20250225083207.0
- 007
- ta
- 008
- 210420e20190821ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ijoa.2019.08.005 $2 doi
- 035 __
- $a (PubMed)31537420
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Bláha, J $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
- 245 10
- $a Surgical conditions with rocuronium versus suxamethonium in cesarean section: a randomized trial / $c J. Bláha, P. Nosková, K. Hlinecká, V. Krakovská, V. Fundová, T. Bartošová, P. Michálek, M. Stříteský
- 520 9_
- $a BACKGROUND: Onset times and conditions for intubation after rocuronium versus suxamethonium at cesarean section have been evaluated, but no study thus far has examined the influence of these neuromuscular blocking drugs on the surgical conditions or their effect on the duration of surgery and the ease of fetal delivery. We aimed to compare the surgical conditions for delivery in parturients who received deep neuromuscular block with rocuronium with those who had induction with suxamethonium. METHODS: Ninety patients undergoing cesarean section under general anesthesia were randomized to receive either rocuronium 0.6 mg/kg or suxamethonium 1 mg/kg for tracheal intubation and delivery. Times to delivery and the quality of surgical conditions, using a five-point Surgical Rating Scale for Delivery (SRSD) ranging from 1 (poor) to 5 (excellent), were evaluated. RESULTS: The median SRSD (range) was found to be significantly better in the rocuronium group [4 (3-5) points vs 3 (2-4) points with suxamethonium (P <0.001)]. Whereas the mean (SD) induction-to-intubation interval was longer with rocuronium [106 (34) s vs 68 (32) s with suxamethonium (95% CI of the difference 24 to 52 s, P <0.001)], the incision-to-delivery interval was shorter in the rocuronium group [147 (68) s vs 196 (51) s with suxamethonium (95% CI of the difference -75 to -24 s, P <0.001)]. The mean induction-to-delivery intervals were similar [268 (73) s vs 276 (63) s, respectively]. CONCLUSIONS: Whereas the induction-to-delivery intervals were comparable, we found rocuronium superior to suxamethonium in allowing better surgical conditions for fetal delivery, which enabled an easier delivery and a shorter incision-to-delivery interval.
- 650 _2
- $a dospělí $7 D000328
- 650 12
- $a císařský řez $7 D002585
- 650 _2
- $a dvojitá slepá metoda $7 D004311
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a těhotenství $7 D011247
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a rokuronium $x farmakologie $7 D000077123
- 650 _2
- $a sukcinylcholin $x farmakologie $7 D013390
- 650 _2
- $a časové faktory $7 D013997
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a randomizované kontrolované studie $7 D016449
- 700 1_
- $a Nosková, P $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
- 700 1_
- $a Hlinecká, Kristýna $u Department of Gynecology and Obstetrics, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic $7 xx0266830
- 700 1_
- $a Krakovská, V $u Neonatology, Department of Gynecology and Obstetrics, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
- 700 1_
- $a Fundová, V $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
- 700 1_
- $a Bartošová, Tereza $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic $7 xx0328751
- 700 1_
- $a Michálek, P $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
- 700 1_
- $a Stříteský, M $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic. Electronic address: martin.stritesky@vfn.cz
- 773 0_
- $w MED00009903 $t International journal of obstetric anesthesia $x 1532-3374 $g Roč. 41 (20190821), s. 14-21
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31537420 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210420 $b ABA008
- 991 __
- $a 20250225083204 $b ABA008
- 999 __
- $a ok $b bmc $g 1651125 $s 1133264
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 41 $c - $d 14-21 $e 20190821 $i 1532-3374 $m International journal of obstetric anesthesia $n Int J Obstet Anesth $x MED00009903
- LZP __
- $a Pubmed-20210420