• Je něco špatně v tomto záznamu ?

Surgical conditions with rocuronium versus suxamethonium in cesarean section: a randomized trial

J. Bláha, P. Nosková, K. Hlinecká, V. Krakovská, V. Fundová, T. Bartošová, P. Michálek, M. Stříteský

. 2020 ; 41 (-) : 14-21. [pub] 20190821

Jazyk angličtina Země Nizozemsko

Typ dokumentu srovnávací studie, časopisecké články, randomizované kontrolované studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc21012885

BACKGROUND: Onset times and conditions for intubation after rocuronium versus suxamethonium at cesarean section have been evaluated, but no study thus far has examined the influence of these neuromuscular blocking drugs on the surgical conditions or their effect on the duration of surgery and the ease of fetal delivery. We aimed to compare the surgical conditions for delivery in parturients who received deep neuromuscular block with rocuronium with those who had induction with suxamethonium. METHODS: Ninety patients undergoing cesarean section under general anesthesia were randomized to receive either rocuronium 0.6 mg/kg or suxamethonium 1 mg/kg for tracheal intubation and delivery. Times to delivery and the quality of surgical conditions, using a five-point Surgical Rating Scale for Delivery (SRSD) ranging from 1 (poor) to 5 (excellent), were evaluated. RESULTS: The median SRSD (range) was found to be significantly better in the rocuronium group [4 (3-5) points vs 3 (2-4) points with suxamethonium (P <0.001)]. Whereas the mean (SD) induction-to-intubation interval was longer with rocuronium [106 (34) s vs 68 (32) s with suxamethonium (95% CI of the difference 24 to 52 s, P <0.001)], the incision-to-delivery interval was shorter in the rocuronium group [147 (68) s vs 196 (51) s with suxamethonium (95% CI of the difference -75 to -24 s, P <0.001)]. The mean induction-to-delivery intervals were similar [268 (73) s vs 276 (63) s, respectively]. CONCLUSIONS: Whereas the induction-to-delivery intervals were comparable, we found rocuronium superior to suxamethonium in allowing better surgical conditions for fetal delivery, which enabled an easier delivery and a shorter incision-to-delivery interval.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21012885
003      
CZ-PrNML
005      
20250225083207.0
007      
ta
008      
210420e20190821ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.ijoa.2019.08.005 $2 doi
035    __
$a (PubMed)31537420
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Bláha, J $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
245    10
$a Surgical conditions with rocuronium versus suxamethonium in cesarean section: a randomized trial / $c J. Bláha, P. Nosková, K. Hlinecká, V. Krakovská, V. Fundová, T. Bartošová, P. Michálek, M. Stříteský
520    9_
$a BACKGROUND: Onset times and conditions for intubation after rocuronium versus suxamethonium at cesarean section have been evaluated, but no study thus far has examined the influence of these neuromuscular blocking drugs on the surgical conditions or their effect on the duration of surgery and the ease of fetal delivery. We aimed to compare the surgical conditions for delivery in parturients who received deep neuromuscular block with rocuronium with those who had induction with suxamethonium. METHODS: Ninety patients undergoing cesarean section under general anesthesia were randomized to receive either rocuronium 0.6 mg/kg or suxamethonium 1 mg/kg for tracheal intubation and delivery. Times to delivery and the quality of surgical conditions, using a five-point Surgical Rating Scale for Delivery (SRSD) ranging from 1 (poor) to 5 (excellent), were evaluated. RESULTS: The median SRSD (range) was found to be significantly better in the rocuronium group [4 (3-5) points vs 3 (2-4) points with suxamethonium (P <0.001)]. Whereas the mean (SD) induction-to-intubation interval was longer with rocuronium [106 (34) s vs 68 (32) s with suxamethonium (95% CI of the difference 24 to 52 s, P <0.001)], the incision-to-delivery interval was shorter in the rocuronium group [147 (68) s vs 196 (51) s with suxamethonium (95% CI of the difference -75 to -24 s, P <0.001)]. The mean induction-to-delivery intervals were similar [268 (73) s vs 276 (63) s, respectively]. CONCLUSIONS: Whereas the induction-to-delivery intervals were comparable, we found rocuronium superior to suxamethonium in allowing better surgical conditions for fetal delivery, which enabled an easier delivery and a shorter incision-to-delivery interval.
650    _2
$a dospělí $7 D000328
650    12
$a císařský řez $7 D002585
650    _2
$a dvojitá slepá metoda $7 D004311
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a těhotenství $7 D011247
650    _2
$a prospektivní studie $7 D011446
650    _2
$a rokuronium $x farmakologie $7 D000077123
650    _2
$a sukcinylcholin $x farmakologie $7 D013390
650    _2
$a časové faktory $7 D013997
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a randomizované kontrolované studie $7 D016449
700    1_
$a Nosková, P $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
700    1_
$a Hlinecká, Kristýna $u Department of Gynecology and Obstetrics, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic $7 xx0266830
700    1_
$a Krakovská, V $u Neonatology, Department of Gynecology and Obstetrics, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
700    1_
$a Fundová, V $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
700    1_
$a Bartošová, Tereza $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic $7 xx0328751
700    1_
$a Michálek, P $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic
700    1_
$a Stříteský, M $u Department of Anesthesiology, Resuscitation and Intensive Medicine, 1st Faculty of Medicine, Charles University and General University Hospital in Prague, Czech Republic. Electronic address: martin.stritesky@vfn.cz
773    0_
$w MED00009903 $t International journal of obstetric anesthesia $x 1532-3374 $g Roč. 41 (20190821), s. 14-21
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31537420 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210420 $b ABA008
991    __
$a 20250225083204 $b ABA008
999    __
$a ok $b bmc $g 1651125 $s 1133264
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 41 $c - $d 14-21 $e 20190821 $i 1532-3374 $m International journal of obstetric anesthesia $n Int J Obstet Anesth $x MED00009903
LZP    __
$a Pubmed-20210420

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...