Comparison of the Baska Mask® and Endotracheal Tube on Hemodynamic and Respiratory Parameters in Septoplasty Cases

H. S. Kuşderci, M. T. Torun, M. Öterkuş

. 2021 ; 122 (1) : 5-13.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21015691

Laryngeal mask (LM) types have been used as an airway device for an alternative to the standard endotracheal tube (ETT). One of the novel type of LM, the Baska Mask®, can be a safe alternative among the airway devices. The purpose of this study is to compare the effects of the new generation supraglottic airway device the Baska Mask® and the ETT on hemodynamic parameters (heart rate, mean arterial pressure), airway pressure and end tidal carbon dioxide (EtCO2) in patients undergoing general anesthesia. After the approval of the ethics committee, 70 patients who underwent septoplasty were included in the study. Written informed consent forms were taken from these patients. Demographic data of the patients were recorded. Hemodynamic data of patients were measured and recorded preoperative, during induction, at the time of intubation 1th, 3th and 5th minute and during extubation. Also, airway pressure and EtCO2 values of the patients were measured and recorded at the time of intubation, 1th, 3th and 5th minutes. Demographic data were similar in both groups. Mean arterial pressure, heart rate and airway pressure were lower in the group 2 (the Baska Mask® group) than in the group 1 (ETT group) and the difference was statistically significant (p<0.05). EtCO2 values were similar in both groups. No patients had tube leakage. In terms of hemodynamic and respiratory parameters the Baska Mask® is more advantageous than the ETT in short-term surgeries.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc21015691
003      
CZ-PrNML
005      
20210618105105.0
007      
ta
008      
210604s2021 xr f 000 0|eng||
009      
AR
024    7_
$a 10.14712/23362936.2021.1 $2 doi
035    __
$a (PubMed)33646937
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Kuşderci, Hatice Selçuk $u Department of Anesthesia and Reanimation, Bandırma State Hospital, Balıkesir, Turkey
245    10
$a Comparison of the Baska Mask® and Endotracheal Tube on Hemodynamic and Respiratory Parameters in Septoplasty Cases / $c H. S. Kuşderci, M. T. Torun, M. Öterkuş
504    __
$a Literatura
520    9_
$a Laryngeal mask (LM) types have been used as an airway device for an alternative to the standard endotracheal tube (ETT). One of the novel type of LM, the Baska Mask®, can be a safe alternative among the airway devices. The purpose of this study is to compare the effects of the new generation supraglottic airway device the Baska Mask® and the ETT on hemodynamic parameters (heart rate, mean arterial pressure), airway pressure and end tidal carbon dioxide (EtCO2) in patients undergoing general anesthesia. After the approval of the ethics committee, 70 patients who underwent septoplasty were included in the study. Written informed consent forms were taken from these patients. Demographic data of the patients were recorded. Hemodynamic data of patients were measured and recorded preoperative, during induction, at the time of intubation 1th, 3th and 5th minute and during extubation. Also, airway pressure and EtCO2 values of the patients were measured and recorded at the time of intubation, 1th, 3th and 5th minutes. Demographic data were similar in both groups. Mean arterial pressure, heart rate and airway pressure were lower in the group 2 (the Baska Mask® group) than in the group 1 (ETT group) and the difference was statistically significant (p&lt;0.05). EtCO2 values were similar in both groups. No patients had tube leakage. In terms of hemodynamic and respiratory parameters the Baska Mask® is more advantageous than the ETT in short-term surgeries.
650    _2
$a celková anestezie $7 D000768
650    _2
$a hemodynamika $7 D006439
650    _2
$a lidé $7 D006801
650    12
$a intratracheální intubace $7 D007442
650    12
$a laryngální masky $7 D017214
655    _2
$a časopisecké články $7 D016428
700    1_
$a Torun, Mümtaz Taner $u Department of Otolaryngology, Bandırma State Hospital, Balıkesir, Turkey
700    1_
$a Öterkuş, Mesut $u Department of Anesthesia and Reanimation, Kafkas University, Kars, Turkey
773    0_
$w MED00013414 $t Prague medical report $x 1214-6994 $g Roč. 122, č. 1 (2021), s. 5-13
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33646937 $y Pubmed
856    41
$u https://pmr.lf1.cuni.cz/media/pdf/pmr_2021122010005.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 7 $c 1071 $y p $z 0
990    __
$a 20210604 $b ABA008
991    __
$a 20210615163025 $b ABA008
999    __
$a ok $b bmc $g 1664053 $s 1136099
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 122 $c 1 $d 5-13 $i 1214-6994 $m Prague Medical Report $n Prague Med. Rep. $x MED00013414
LZP    __
$b NLK118 $a Pubmed-20210604

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...