• Je něco špatně v tomto záznamu ?

Stanovenie imunosupresívnych liečiv pomocou LC/MS-MS
[Determination of immunosuppressive drugs by LC/MS-MS]

Martina Valachovičová, Jana Príbojová, Csilla Mišľanová

. 2021 ; 115 (3) : 138-144.

Status minimální Jazyk slovenština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc21016531

In Slovakia, approximately 200 kidneys are transplanted annually. Each patient-recipient must be adjusted to the most appropriate immunosuppressive treatment to eliminate renal rejection. The high-performance liquid chromatography connected to tandem mass spectrometry was validated for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus in the whole blood. For the determination, C18 analytical column with a gradient of 10 mmol/L ammonium acetate, pH 4.0 and acetonitrile was used. A simple protein precipitation with zinc sulphate: methanol was used for the pretreatment of whole blood. The method provides reliable and reproducible results and it can be introduced to routine clinical practice.

Determination of immunosuppressive drugs by LC/MS-MS

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc21016531
003      
CZ-PrNML
005      
20210624092754.0
007      
ta
008      
210624s2021 xr d f 000 0|slo||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a slo $b eng
044    __
$a xr
100    1_
$a Valachovičová, Martina $7 xx0224779 $u Fakulta ošetrovateľstva a zdravotníckych odborných štúdií, Slovenská zdravotnícka univerzita v Bratislave, Bratislava
245    10
$a Stanovenie imunosupresívnych liečiv pomocou LC/MS-MS / $c Martina Valachovičová, Jana Príbojová, Csilla Mišľanová
246    31
$a Determination of immunosuppressive drugs by LC/MS-MS
504    __
$a Literatura
520    3_
$a In Slovakia, approximately 200 kidneys are transplanted annually. Each patient-recipient must be adjusted to the most appropriate immunosuppressive treatment to eliminate renal rejection. The high-performance liquid chromatography connected to tandem mass spectrometry was validated for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus in the whole blood. For the determination, C18 analytical column with a gradient of 10 mmol/L ammonium acetate, pH 4.0 and acetonitrile was used. A simple protein precipitation with zinc sulphate: methanol was used for the pretreatment of whole blood. The method provides reliable and reproducible results and it can be introduced to routine clinical practice.
700    1_
$a Príbojová, Jana $7 xx0224794 $u Fakulta ošetrovateľstva a zdravotníckych odborných štúdií, Slovenská zdravotnícka univerzita v Bratislave, Bratislava
700    1_
$a Mišľanová, Csilla $7 xx0261457 $u Fakulta ošetrovateľstva a zdravotníckych odborných štúdií, Slovenská zdravotnícka univerzita v Bratislave, Bratislava; Katedra analytickej chémie, Prírodovedecká fakulta, Univerzita Komenského, Bratislava
773    0_
$t Chemické listy $x 0009-2770 $g Roč. 115, č. 3 (2021), s. 138-144 $w MED00011010
856    41
$u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/3805/3724 $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 0 $z 0
990    __
$a 20210622160419 $b ABA008
991    __
$a 20210624092753 $b ABA008
999    __
$a min $b bmc $g 1665954 $s 1136951
BAS    __
$a 3
BMC    __
$a 2021 $b 115 $c 3 $d 138-144 $i 0009-2770 $m Chemické listy $x MED00011010
LZP    __
$a NLK 2021-03/mk

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...