Does the Femoral CCD Angle Measurement in a Standard AP Projection Correlate with the True Anatomical Shape of the Femur [Koreluje CCD úhel naměřený ve standardní AP projekci se skutečným anatomickým tvarem proximálního femuru]
J. Heřt, V. Barták, P. Fulín, D. Pokorný, A. Sosna
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
- MeSH
- diafýzy MeSH
- femur * diagnostické zobrazování MeSH
- krček femuru diagnostické zobrazování MeSH
- lidé MeSH
- počítačová rentgenová tomografie * MeSH
- radiografie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY This study aims to ascertain whether a high anteversion of the femoral neck can influence the measurement of the caputcollum-diaphyseal (CCD) angle on a plain anteroposterior (AP) radiograph of the proximal femur. MATERIAL AND METHODS We developed a new method of measuring the CCD angle and femoral neck version of the femur. This was done with the use of a computer program that utilised the measurement of the entire visualised area of femoral neck and shaft to calculate their long axis. Using this method, we measured the CCD angle and femoral neck version (FNV) of 100 photographed cadaveric femurs in two projections: The condylar line (CL) projection and the femoral neck (FN) projection. The same method was applied to 50 radiographs of the same femurs. The femurs were divided into three groups depending on the femoral neck version: Retro (FNV of <0°), Normal (FNV of 0-15°) and Ante (FNV of >15°) RESULTS We found a statistically significant difference in the CCD angle measured in the FN and CL projections in the Normal and Ante groups but not in the Retro group. There is a significant correlation between the increase in FNV and the difference between the measured CCD values in the FL and CL projections. The femoral neck version of our cadaveric femurs varied from -14. 4° to 31. 5° which is a range of more than 35°. CONCLUSIONS From the results, it is clear that with an increase in femoral neck anteversion, there is a statistically significant difference in the CCD angle measured between the two projections. This difference can be up to almost 10°. Surgeons should be aware of the limitation of the AP projection when planning for surgery on the hip. Key words: femoral neck anteversion, CCD angle, templating, preoperative planning.
Koreluje CCD úhel naměřený ve standardní AP projekci se skutečným anatomickým tvarem proximálního femuru
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21017485
- 003
- CZ-PrNML
- 005
- 20210803105034.0
- 007
- ta
- 008
- 210723s2021 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $2 doi $a 10.55095/achot2021/027
- 035 __
- $a (PubMed)34228611
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Heřt, Jan, $d 1989- $7 xx0256941 $u 1st Department of Orthopaedics, 1st Faculty of Medicine, Charles University and Motol University Hospital, Prague
- 245 10
- $a Does the Femoral CCD Angle Measurement in a Standard AP Projection Correlate with the True Anatomical Shape of the Femur / $c J. Heřt, V. Barták, P. Fulín, D. Pokorný, A. Sosna
- 246 31
- $a Koreluje CCD úhel naměřený ve standardní AP projekci se skutečným anatomickým tvarem proximálního femuru
- 504 __
- $a Literatura
- 520 9_
- $a PURPOSE OF THE STUDY This study aims to ascertain whether a high anteversion of the femoral neck can influence the measurement of the caputcollum-diaphyseal (CCD) angle on a plain anteroposterior (AP) radiograph of the proximal femur. MATERIAL AND METHODS We developed a new method of measuring the CCD angle and femoral neck version of the femur. This was done with the use of a computer program that utilised the measurement of the entire visualised area of femoral neck and shaft to calculate their long axis. Using this method, we measured the CCD angle and femoral neck version (FNV) of 100 photographed cadaveric femurs in two projections: The condylar line (CL) projection and the femoral neck (FN) projection. The same method was applied to 50 radiographs of the same femurs. The femurs were divided into three groups depending on the femoral neck version: Retro (FNV of <0°), Normal (FNV of 0-15°) and Ante (FNV of >15°) RESULTS We found a statistically significant difference in the CCD angle measured in the FN and CL projections in the Normal and Ante groups but not in the Retro group. There is a significant correlation between the increase in FNV and the difference between the measured CCD values in the FL and CL projections. The femoral neck version of our cadaveric femurs varied from -14. 4° to 31. 5° which is a range of more than 35°. CONCLUSIONS From the results, it is clear that with an increase in femoral neck anteversion, there is a statistically significant difference in the CCD angle measured between the two projections. This difference can be up to almost 10°. Surgeons should be aware of the limitation of the AP projection when planning for surgery on the hip. Key words: femoral neck anteversion, CCD angle, templating, preoperative planning.
- 650 _2
- $a diafýzy $7 D018483
- 650 12
- $a femur $x diagnostické zobrazování $7 D005269
- 650 _2
- $a krček femuru $x diagnostické zobrazování $7 D005272
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a radiografie $7 D011859
- 650 12
- $a počítačová rentgenová tomografie $7 D014057
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Barták, Vladislav $7 xx0093686 $u 1st Department of Orthopaedics, 1st Faculty of Medicine, Charles University and Motol University Hospital, Prague
- 700 1_
- $a Fulín, Petr $7 xx0231618 $u 1st Department of Orthopaedics, 1st Faculty of Medicine, Charles University and Motol University Hospital, Prague
- 700 1_
- $a Pokorný, David, $d 1968- $7 jn20001103568 $u 1st Department of Orthopaedics, 1st Faculty of Medicine, Charles University and Motol University Hospital, Prague
- 700 1_
- $a Sosna, Antonín, $d 1943- $7 jn20000710566 $u 1st Department of Orthopaedics, 1st Faculty of Medicine, Charles University and Motol University Hospital, Prague
- 773 0_
- $w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca $x 0001-5415 $g Roč. 88, č. 3 (2021), s. 169-175
- 856 41
- $u https://achot.cz/pdfs/ach/2021/03/01.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 8 $c 507 $y p $z 0
- 990 __
- $a 20210723 $b ABA008
- 991 __
- $a 20210729114348 $b ABA008
- 999 __
- $a ok $b bmc $g 1678432 $s 1137927
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 88 $c 3 $d 169-175 $e 20210621 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
- LZP __
- $b NLK118 $a Pubmed-20210723