A Novel Statistical Model for Predicting the Efficacy of Vagal Nerve Stimulation in Patients With Epilepsy (Pre-X-Stim) Is Applicable to Different EEG Systems

E. Korit Áková, I. Doležalová, J. Chládek, T. Jurková, J. Chrastina, F. Plešinger, R. Roman, M. Pail, P. Jurák, DJ. Shaw, M. Brázdil

. 2021 ; 15 (-) : 635787. [pub] 20210511

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21017790

Grantová podpora
NV19-04-00343 MZ0 CEP - Centrální evidence projektů

Background: Identifying patients with intractable epilepsy who would benefit from therapeutic chronic vagal nerve stimulation (VNS) preoperatively remains a major clinical challenge. We have developed a statistical model for predicting VNS efficacy using only routine preimplantation electroencephalogram (EEG) recorded with the TruScan EEG device (Brazdil et al., 2019). It remains to be seen, however, if this model can be applied in different clinical settings. Objective: To validate our model using EEG data acquired with a different recording system. Methods: We identified a validation cohort of eight patients implanted with VNS, whose preimplantation EEG was recorded on the BrainScope device and who underwent the EEG recording according to the protocol. The classifier developed in our earlier work, named Pre-X-Stim, was then employed to classify these patients as predicted responders or non-responders based on the dynamics in EEG power spectra. Predicted and real-world outcomes were compared to establish the applicability of this classifier. In total, two validation experiments were performed using two different validation approaches (single classifier or classifier voting). Results: The classifier achieved 75% accuracy, 67% sensitivity, and 100% specificity. Only two patients, both real-life responders, were classified incorrectly in both validation experiments. Conclusion: We have validated the Pre-X-Stim model on EEGs from a different recording system, which indicates its application under different technical conditions. Our approach, based on preoperative EEG, is easily applied and financially undemanding and presents great potential for real-world clinical use.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21017790
003      
CZ-PrNML
005      
20210729104030.0
007      
ta
008      
210726s2021 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3389/fnins.2021.635787 $2 doi
035    __
$a (PubMed)34045942
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Korit Áková, Eva $u Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University, Brno, Czechia
245    12
$a A Novel Statistical Model for Predicting the Efficacy of Vagal Nerve Stimulation in Patients With Epilepsy (Pre-X-Stim) Is Applicable to Different EEG Systems / $c E. Korit Áková, I. Doležalová, J. Chládek, T. Jurková, J. Chrastina, F. Plešinger, R. Roman, M. Pail, P. Jurák, DJ. Shaw, M. Brázdil
520    9_
$a Background: Identifying patients with intractable epilepsy who would benefit from therapeutic chronic vagal nerve stimulation (VNS) preoperatively remains a major clinical challenge. We have developed a statistical model for predicting VNS efficacy using only routine preimplantation electroencephalogram (EEG) recorded with the TruScan EEG device (Brazdil et al., 2019). It remains to be seen, however, if this model can be applied in different clinical settings. Objective: To validate our model using EEG data acquired with a different recording system. Methods: We identified a validation cohort of eight patients implanted with VNS, whose preimplantation EEG was recorded on the BrainScope device and who underwent the EEG recording according to the protocol. The classifier developed in our earlier work, named Pre-X-Stim, was then employed to classify these patients as predicted responders or non-responders based on the dynamics in EEG power spectra. Predicted and real-world outcomes were compared to establish the applicability of this classifier. In total, two validation experiments were performed using two different validation approaches (single classifier or classifier voting). Results: The classifier achieved 75% accuracy, 67% sensitivity, and 100% specificity. Only two patients, both real-life responders, were classified incorrectly in both validation experiments. Conclusion: We have validated the Pre-X-Stim model on EEGs from a different recording system, which indicates its application under different technical conditions. Our approach, based on preoperative EEG, is easily applied and financially undemanding and presents great potential for real-world clinical use.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Doležalová, Irena $u Brno Epilepsy Center, Department of Neurology and Neurosurgery, St. Anne's University Hospital and Medical Faculty of Masaryk University, Brno, Czechia
700    1_
$a Chládek, Jan $u Behavioral and Social Neuroscience Research Group, Central European Institute of Technology, Masaryk University, Brno, Czechia $u Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia
700    1_
$a Jurková, Tereza $u Brno Epilepsy Center, Department of Neurology and Neurosurgery, St. Anne's University Hospital and Medical Faculty of Masaryk University, Brno, Czechia
700    1_
$a Chrastina, Jan $u Brno Epilepsy Center, Department of Neurology and Neurosurgery, St. Anne's University Hospital and Medical Faculty of Masaryk University, Brno, Czechia
700    1_
$a Plešinger, Filip $u Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia
700    1_
$a Roman, Robert $u Behavioral and Social Neuroscience Research Group, Central European Institute of Technology, Masaryk University, Brno, Czechia
700    1_
$a Pail, Martin $u Brno Epilepsy Center, Department of Neurology and Neurosurgery, St. Anne's University Hospital and Medical Faculty of Masaryk University, Brno, Czechia
700    1_
$a Jurák, Pavel $u Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czechia
700    1_
$a Shaw, Daniel J $u Behavioral and Social Neuroscience Research Group, Central European Institute of Technology, Masaryk University, Brno, Czechia
700    1_
$a Brázdil, Milan $u Brno Epilepsy Center, Department of Neurology and Neurosurgery, St. Anne's University Hospital and Medical Faculty of Masaryk University, Brno, Czechia $u Behavioral and Social Neuroscience Research Group, Central European Institute of Technology, Masaryk University, Brno, Czechia
773    0_
$w MED00163313 $t Frontiers in neuroscience $x 1662-4548 $g Roč. 15, č. - (2021), s. 635787
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34045942 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20210726 $b ABA008
991    __
$a 20210729104029 $b ABA008
999    __
$a ind $b bmc $g 1676421 $s 1138232
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 15 $c - $d 635787 $e 20210511 $i 1662-4548 $m Frontiers in neuroscience $n Front Neurosci $x MED00163313
GRA    __
$a NV19-04-00343 $p MZ0
LZP    __
$a Pubmed-20210726

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...