7-Dehydrocholesterol is an essential biomarker of Smith-Lemli-Opitz syndrome, a congenital autosomal recessive disorder. This study shows for the first time that electrochemical oxidation of 7-dehydrocholesterol can be used for its voltammetric determination. Two classes of supporting electrolytes in acetonitrile and a mixture of acetonitrile-water were used: inorganic acids known to promote structural changes of steroids and indifferent electrolytes. Oxidation of 7-dehydrocholesterol at ca +0.8 V (vs. Ag/AgNO3 in acetonitrile) in 0.1 mol L-1 NaClO4 in acetonitrile is useful for its voltammetric detection using common bare electrode materials. Detection limits for 7-dehydrocholesterol lie in the low micromolar range for all the working electrodes, including boron-doped diamond (0.4 μmol L-1) and disposable thin-film platinum electrodes (0.5 μmol L-1), which are advantageous because of the low volumes of studied solutions. After Bligh-Dyer extraction, quantification of 7-dehydrocholesterol concentration (boron-doped diamond) or concentration range (thin-film platinum) is easily attainable in artificial serum. The mere knowledge of the concentration range provides clinically valuable information, as 7-dehydrocholesterol levels are employed for SLOS diagnosis as a binary criterion (elevated, tens to hundreds μmol L-1 in symptomatic/non-elevated, typically bellow 1 μmol L-1 in healthy individuals in plasma). Moreover, it is shown that 7-dehydrocholesterol (provitamin D3) and cholecalciferol (vitamin D3) can be oxidized in 0.1 mol L-1 HClO4 in acetonitrile. Under these conditions, their voltammetric response changes dramatically, and their oxidation potential difference transiently increases from 0.08 V to 0.25 V, which should facilitate their simultaneous voltammetric determination. This work constitutes a foundation for a reliable and straightforward method for Smith-Lemli-Opitz syndrome diagnosis and monitoring 7-dehydrocholesterol's biotransformation to cholecalciferol.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21018439
- 003
- CZ-PrNML
- 005
- 20210830100026.0
- 007
- ta
- 008
- 210728s2021 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2021.122260 $2 doi
- 035 __
- $a (PubMed)33838771
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Klouda, Jan $u Charles University, Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, Albertov 6, CZ-128 43 Prague 2, Czech Republic. Electronic address: jan.klouda@natur.cuni.cz
- 245 10
- $a Voltammetry of 7-dehydrocholesterol as a new and useful tool for Smith-Lemli-Opitz syndrome diagnosis / $c J. Klouda, L. Benešová, P. Kočovský, K. Schwarzová-Pecková
- 520 9_
- $a 7-Dehydrocholesterol is an essential biomarker of Smith-Lemli-Opitz syndrome, a congenital autosomal recessive disorder. This study shows for the first time that electrochemical oxidation of 7-dehydrocholesterol can be used for its voltammetric determination. Two classes of supporting electrolytes in acetonitrile and a mixture of acetonitrile-water were used: inorganic acids known to promote structural changes of steroids and indifferent electrolytes. Oxidation of 7-dehydrocholesterol at ca +0.8 V (vs. Ag/AgNO3 in acetonitrile) in 0.1 mol L-1 NaClO4 in acetonitrile is useful for its voltammetric detection using common bare electrode materials. Detection limits for 7-dehydrocholesterol lie in the low micromolar range for all the working electrodes, including boron-doped diamond (0.4 μmol L-1) and disposable thin-film platinum electrodes (0.5 μmol L-1), which are advantageous because of the low volumes of studied solutions. After Bligh-Dyer extraction, quantification of 7-dehydrocholesterol concentration (boron-doped diamond) or concentration range (thin-film platinum) is easily attainable in artificial serum. The mere knowledge of the concentration range provides clinically valuable information, as 7-dehydrocholesterol levels are employed for SLOS diagnosis as a binary criterion (elevated, tens to hundreds μmol L-1 in symptomatic/non-elevated, typically bellow 1 μmol L-1 in healthy individuals in plasma). Moreover, it is shown that 7-dehydrocholesterol (provitamin D3) and cholecalciferol (vitamin D3) can be oxidized in 0.1 mol L-1 HClO4 in acetonitrile. Under these conditions, their voltammetric response changes dramatically, and their oxidation potential difference transiently increases from 0.08 V to 0.25 V, which should facilitate their simultaneous voltammetric determination. This work constitutes a foundation for a reliable and straightforward method for Smith-Lemli-Opitz syndrome diagnosis and monitoring 7-dehydrocholesterol's biotransformation to cholecalciferol.
- 650 12
- $a dehydrocholesteroly $x analýza $7 D003684
- 650 _2
- $a diamant $7 D018130
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a oxidoreduktasy působící na CH-CH vazby $7 D044925
- 650 12
- $a Smithův-Lemliho-Opitzův syndrom $x diagnóza $7 D019082
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Benešová, Lenka $u Charles University, Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, Albertov 6, CZ-128 43 Prague 2, Czech Republic. Electronic address: lenka.benesova@natur.cuni.cz
- 700 1_
- $a Kočovský, Pavel $u Charles University, Faculty of Science, Department of Organic Chemistry, Albertov 6, CZ-128 43 Prague 2, Czech Republic; Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Flemingovo nám. 2, CZ-166 10 Prague 6, Czech Republic. Electronic address: pavel.kocovsky@natur.cuni.cz
- 700 1_
- $a Schwarzová-Pecková, Karolina $u Charles University, Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, Albertov 6, CZ-128 43 Prague 2, Czech Republic. Electronic address: karolina.schwarzova@natur.cuni.cz
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 229, č. - (2021), s. 122260
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33838771 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100027 $b ABA008
- 999 __
- $a ok $b bmc $g 1689523 $s 1138883
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 229 $c - $d 122260 $e 20210306 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20210728