Development and performance assessment of an advanced Lucas-Kanade algorithm for dose mapping of cervical cancer external radiotherapy and brachytherapy plans
V. Novák, J. Ptáček, P. Fiala, Z. Vlachová, P. Jašková
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2000
Free Medical Journals
od 2000
Open Journal Systems (OJS)
od 2004
PubMed Central
od 2000
Europe PubMed Central
od 2000
ProQuest Central
od 2000-03-01
Health & Medicine (ProQuest)
od 2000-03-01
Wiley-Blackwell Open Access Titles
od 2000
ROAD: Directory of Open Access Scholarly Resources
od 2000
PubMed
33942952
DOI
10.1002/acm2.13249
Knihovny.cz E-zdroje
- MeSH
- algoritmy MeSH
- brachyterapie * MeSH
- celková dávka radioterapie MeSH
- lidé MeSH
- nádory děložního čípku * diagnostické zobrazování radioterapie MeSH
- plánování radioterapie pomocí počítače MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: The aim of this study was to verify the possibility of summing the dose distributions of combined radiotherapeutic treatment of cervical cancer using the extended Lucas-Kanade algorithm for deformable image registration. MATERIALS AND METHODS: First, a deformable registration of planning computed tomography images for the external radiotherapy and brachytherapy treatment of 10 patients with different parameter settings of the Lucas-Kanade algorithm was performed. By evaluating the registered data using landmarks distance, root mean square error of Hounsfield units and 2D gamma analysis, the optimal parameter values were found. Next, with another group of 10 patients, the accuracy of the dose mapping of the optimized Lucas-Kanade algorithm was assessed and compared with Horn-Schunck and modified Demons algorithms using dose differences at landmarks. RESULTS: The best results of the Lucas-Kanade deformable registration were achieved for two pyramid levels in combination with a window size of 3 voxels. With this registration setting, the average landmarks distance was 2.35 mm, the RMSE was the smallest and the average gamma score reached a value of 86.7%. The mean dose difference at the landmarks after mapping the external radiotherapy and brachytherapy dose distributions was 1.33 Gy. A statistically significant difference was observed on comparing the Lucas-Kanade method with the Horn-Schunck and Demons algorithms, where after the deformable registration, the average difference in dose was 1.60 Gy (P-value: 0.0055) and 1.69 Gy (P-value: 0.0012), respectively. CONCLUSION: Lucas-Kanade deformable registration can lead to a more accurate model of dose accumulation and provide a more realistic idea of the dose distribution.
Department of Medical Physics and Radiation Protection University Hospital Olomouc Czech Republic
Department of Nuclear Medicine University Hospital Olomouc Czech Republic
Department of Oncology University Hospital Olomouc Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21018696
- 003
- CZ-PrNML
- 005
- 20210830100258.0
- 007
- ta
- 008
- 210728s2021 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/acm2.13249 $2 doi
- 035 __
- $a (PubMed)33942952
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Novák, Václav $u Department of Medical Physics and Radiation Protection, University Hospital Olomouc, Czech Republic
- 245 10
- $a Development and performance assessment of an advanced Lucas-Kanade algorithm for dose mapping of cervical cancer external radiotherapy and brachytherapy plans / $c V. Novák, J. Ptáček, P. Fiala, Z. Vlachová, P. Jašková
- 520 9_
- $a PURPOSE: The aim of this study was to verify the possibility of summing the dose distributions of combined radiotherapeutic treatment of cervical cancer using the extended Lucas-Kanade algorithm for deformable image registration. MATERIALS AND METHODS: First, a deformable registration of planning computed tomography images for the external radiotherapy and brachytherapy treatment of 10 patients with different parameter settings of the Lucas-Kanade algorithm was performed. By evaluating the registered data using landmarks distance, root mean square error of Hounsfield units and 2D gamma analysis, the optimal parameter values were found. Next, with another group of 10 patients, the accuracy of the dose mapping of the optimized Lucas-Kanade algorithm was assessed and compared with Horn-Schunck and modified Demons algorithms using dose differences at landmarks. RESULTS: The best results of the Lucas-Kanade deformable registration were achieved for two pyramid levels in combination with a window size of 3 voxels. With this registration setting, the average landmarks distance was 2.35 mm, the RMSE was the smallest and the average gamma score reached a value of 86.7%. The mean dose difference at the landmarks after mapping the external radiotherapy and brachytherapy dose distributions was 1.33 Gy. A statistically significant difference was observed on comparing the Lucas-Kanade method with the Horn-Schunck and Demons algorithms, where after the deformable registration, the average difference in dose was 1.60 Gy (P-value: 0.0055) and 1.69 Gy (P-value: 0.0012), respectively. CONCLUSION: Lucas-Kanade deformable registration can lead to a more accurate model of dose accumulation and provide a more realistic idea of the dose distribution.
- 650 _2
- $a algoritmy $7 D000465
- 650 12
- $a brachyterapie $7 D001918
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a celková dávka radioterapie $7 D011879
- 650 _2
- $a plánování radioterapie pomocí počítače $7 D011880
- 650 12
- $a nádory děložního čípku $x diagnostické zobrazování $x radioterapie $7 D002583
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Ptáček, Jaroslav $u Department of Medical Physics and Radiation Protection, University Hospital Olomouc, Czech Republic $u Department of Nuclear Medicine, University Hospital Olomouc, Czech Republic
- 700 1_
- $a Fiala, Petr $u Department of Medical Physics and Radiation Protection, University Hospital Olomouc, Czech Republic
- 700 1_
- $a Vlachová, Zuzana $u Department of Oncology, University Hospital Olomouc, Czech Republic
- 700 1_
- $a Jašková, Paulina $u Department of Oncology, University Hospital Olomouc, Czech Republic
- 773 0_
- $w MED00182991 $t Journal of applied clinical medical physics $x 1526-9914 $g Roč. 22, č. 5 (2021), s. 69-78
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33942952 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100258 $b ABA008
- 999 __
- $a ok $b bmc $g 1689711 $s 1139142
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 22 $c 5 $d 69-78 $e 20210504 $i 1526-9914 $m Journal of applied clinical medical physics $n J Appl Clin Med Phys $x MED00182991
- LZP __
- $a Pubmed-20210728