Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience
J. Ferda, T. Vendiš, T. Flohr, B. Schmidt, A. Henning, S. Ulzheimer, L. Pecen, E. Ferdová, J. Baxa, H. Mírka
Jazyk angličtina Země Irsko
Typ dokumentu časopisecké články
- MeSH
- fantomy radiodiagnostické MeSH
- fotony * MeSH
- lidé MeSH
- plíce MeSH
- počítačová rentgenová tomografie * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: to assess the feasibility of CT with an integrated photon-counting-detector system (PC-CT) in the body imaging of clinical patients. METHODS: 120 examinations using photon counting detector CT were evaluated in six groups: 1/ a standard-dose lung, 2/ low-dose lung, 3/ ultra-high resolution (UHR) lung, 4/ standard-dose abdominal, 5/ lower-dose abdominal, 6/ UHR abdominal CTA. All CT examinations were performed on a single-source prototype device equipped with a photon counting detector covering a 50 cm scan field of view. Standard dose examinations were performed with the use of detector element size of 0.4 mm, ultra-high-resolution examinations with the detector element size of 0.2 mm, respectively. The stability of the system during imaging was tested. The diagnostic quality of the acquired images was assessed based on the imaging of key structures and the noise level in five-point scale, the effective dose equivalent, dose length product and noise level, and also relation to body mass index and body surface area were compared with three similar groups of CT images made with energy integrating high end scanner. The parameters were evaluated using Wilcoxon test for independent samples, the independence was tested using Kruskal-Wallis test. RESULTS: When PC-CT images radiation dose is compared with the similar imaging using energy integrating CT, the PC-CT shows lower dose in ultra-high resolution mode, the dose is significantly lower (p < 0.0001), the standard dose examinations were performed with the comparable radiation doses. PC-CT exhibited the significantly higher ratio between parenchyma signal and background noise both in lung and in abdominal imaging (p < 0.0001). CONCLUSIONS: PC-CT showed imaging stability and excellent diagnostic quality at dose values that are comparable or better to the quality of energy integrating CT, the better signal and improved resolution is most important advantage of photon counting detector CT over energy integrating detector CT.
Computed Tomography Development Siemens Healthcare GmbH Computed Tomography 91301 Forchheim Germany
Department of the Imaging University Hospital Pilsen Alej Svobody 80 323 00 Pilsen Czechia
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21018910
- 003
- CZ-PrNML
- 005
- 20210830100500.0
- 007
- ta
- 008
- 210728s2021 ie f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ejrad.2021.109614 $2 doi
- 035 __
- $a (PubMed)33657475
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ie
- 100 1_
- $a Ferda, Jiří $u Department of the Imaging, University Hospital Pilsen, Alej Svobody 80, 323 00, Pilsen, Czechia. Electronic address: ferda@fnplzen.cz
- 245 10
- $a Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience / $c J. Ferda, T. Vendiš, T. Flohr, B. Schmidt, A. Henning, S. Ulzheimer, L. Pecen, E. Ferdová, J. Baxa, H. Mírka
- 520 9_
- $a OBJECTIVES: to assess the feasibility of CT with an integrated photon-counting-detector system (PC-CT) in the body imaging of clinical patients. METHODS: 120 examinations using photon counting detector CT were evaluated in six groups: 1/ a standard-dose lung, 2/ low-dose lung, 3/ ultra-high resolution (UHR) lung, 4/ standard-dose abdominal, 5/ lower-dose abdominal, 6/ UHR abdominal CTA. All CT examinations were performed on a single-source prototype device equipped with a photon counting detector covering a 50 cm scan field of view. Standard dose examinations were performed with the use of detector element size of 0.4 mm, ultra-high-resolution examinations with the detector element size of 0.2 mm, respectively. The stability of the system during imaging was tested. The diagnostic quality of the acquired images was assessed based on the imaging of key structures and the noise level in five-point scale, the effective dose equivalent, dose length product and noise level, and also relation to body mass index and body surface area were compared with three similar groups of CT images made with energy integrating high end scanner. The parameters were evaluated using Wilcoxon test for independent samples, the independence was tested using Kruskal-Wallis test. RESULTS: When PC-CT images radiation dose is compared with the similar imaging using energy integrating CT, the PC-CT shows lower dose in ultra-high resolution mode, the dose is significantly lower (p < 0.0001), the standard dose examinations were performed with the comparable radiation doses. PC-CT exhibited the significantly higher ratio between parenchyma signal and background noise both in lung and in abdominal imaging (p < 0.0001). CONCLUSIONS: PC-CT showed imaging stability and excellent diagnostic quality at dose values that are comparable or better to the quality of energy integrating CT, the better signal and improved resolution is most important advantage of photon counting detector CT over energy integrating detector CT.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a plíce $7 D008168
- 650 _2
- $a fantomy radiodiagnostické $7 D019047
- 650 12
- $a fotony $7 D017785
- 650 12
- $a počítačová rentgenová tomografie $7 D014057
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Vendiš, Tomáš $u Department of the Imaging, University Hospital Pilsen, Alej Svobody 80, 323 00, Pilsen, Czechia
- 700 1_
- $a Flohr, Thomas $u Computed Tomography Development, Siemens Healthcare GmbH, Computed Tomography, 91301, Forchheim, Germany
- 700 1_
- $a Schmidt, Bernhard $u Computed Tomography Development, Siemens Healthcare GmbH, Computed Tomography, 91301, Forchheim, Germany
- 700 1_
- $a Henning, André $u Computed Tomography Development, Siemens Healthcare GmbH, Computed Tomography, 91301, Forchheim, Germany
- 700 1_
- $a Ulzheimer, Stefan $u Computed Tomography Development, Siemens Healthcare GmbH, Computed Tomography, 91301, Forchheim, Germany
- 700 1_
- $a Pecen, Ladislav $u Department of the Imaging, University Hospital Pilsen, Alej Svobody 80, 323 00, Pilsen, Czechia
- 700 1_
- $a Ferdová, Eva $u Department of the Imaging, University Hospital Pilsen, Alej Svobody 80, 323 00, Pilsen, Czechia
- 700 1_
- $a Baxa, Jan $u Department of the Imaging, University Hospital Pilsen, Alej Svobody 80, 323 00, Pilsen, Czechia
- 700 1_
- $a Mírka, Hynek $u Department of the Imaging, University Hospital Pilsen, Alej Svobody 80, 323 00, Pilsen, Czechia
- 773 0_
- $w MED00009640 $t European journal of radiology $x 1872-7727 $g Roč. 137, č. - (2021), s. 109614
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33657475 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100501 $b ABA008
- 999 __
- $a ok $b bmc $g 1689868 $s 1139356
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 137 $c - $d 109614 $e 20210224 $i 1872-7727 $m European journal of radiology $n Eur J Radiol $x MED00009640
- LZP __
- $a Pubmed-20210728