A Smartphone Camera Colorimetric Assay of Acetylcholinesterase and Butyrylcholinesterase Activity
M. Pohanka, J. Zakova
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
Grantová podpora
TH03030336
Technologická Agentura České Republiky
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
33807562
DOI
10.3390/s21051796
Knihovny.cz E-zdroje
- MeSH
- acetylcholinesterasa * MeSH
- butyrylcholinesterasa * MeSH
- cholinesterasové inhibitory MeSH
- chytrý telefon MeSH
- kolorimetrie MeSH
- lidé MeSH
- spektrofotometrie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) can serve as biochemical markers of various pathologies like liver disfunction and poisonings by nerve agents. Ellman's assay is the standard spectrophotometric method to measure cholinesterase activity in clinical laboratories. The authors present a new colorimetric test to assess AChE and BChE activity in biological samples using chromogenic reagents, treated 3D-printed measuring pads and a smartphone camera as a signal detector. Multiwell pads treated with reagent substrates 2,6-dichlorophenolindophenyl acetate, indoxylacetate, ethoxyresorufin and methoxyresorufin were prepared and tested for AChE and BChE. In the experiments, 3D-printed pads containing indoxylacetate as a chromogenic substrate were optimal for analytical purposes. The best results were achieved using the red (R) channel, where the limit of detection was 4.05 µkat/mL for BChE and 4.38 µkat/mL for AChE using a 40 µL sample and a 60 min assay. The major advantage of this method is its overall simplicity, as samples are applied directly without any specific treatment or added reagents. The assay was also validated to the standard Ellman's assay using human plasma samples. In conclusion, this smartphone camera-based colorimetric assay appears to have practical applicability and to be a suitable method for point-of-care testing because it does not require specific manipulation, additional education of staff or use of sophisticated analytical instruments.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019096
- 003
- CZ-PrNML
- 005
- 20210830100656.0
- 007
- ta
- 008
- 210728s2021 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s21051796 $2 doi
- 035 __
- $a (PubMed)33807562
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Pohanka, Miroslav $u Faculty of Military Health Sciences, University of Defense, Trebesska 1575, CZ-50001 Hradec Kralove, Czech Republic
- 245 12
- $a A Smartphone Camera Colorimetric Assay of Acetylcholinesterase and Butyrylcholinesterase Activity / $c M. Pohanka, J. Zakova
- 520 9_
- $a Acetylcholinesterase (AChE) and butyrylcholinesterase (BChE) can serve as biochemical markers of various pathologies like liver disfunction and poisonings by nerve agents. Ellman's assay is the standard spectrophotometric method to measure cholinesterase activity in clinical laboratories. The authors present a new colorimetric test to assess AChE and BChE activity in biological samples using chromogenic reagents, treated 3D-printed measuring pads and a smartphone camera as a signal detector. Multiwell pads treated with reagent substrates 2,6-dichlorophenolindophenyl acetate, indoxylacetate, ethoxyresorufin and methoxyresorufin were prepared and tested for AChE and BChE. In the experiments, 3D-printed pads containing indoxylacetate as a chromogenic substrate were optimal for analytical purposes. The best results were achieved using the red (R) channel, where the limit of detection was 4.05 µkat/mL for BChE and 4.38 µkat/mL for AChE using a 40 µL sample and a 60 min assay. The major advantage of this method is its overall simplicity, as samples are applied directly without any specific treatment or added reagents. The assay was also validated to the standard Ellman's assay using human plasma samples. In conclusion, this smartphone camera-based colorimetric assay appears to have practical applicability and to be a suitable method for point-of-care testing because it does not require specific manipulation, additional education of staff or use of sophisticated analytical instruments.
- 650 12
- $a acetylcholinesterasa $7 D000110
- 650 12
- $a butyrylcholinesterasa $7 D002091
- 650 _2
- $a cholinesterasové inhibitory $7 D002800
- 650 _2
- $a kolorimetrie $7 D003124
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a chytrý telefon $7 D000068997
- 650 _2
- $a spektrofotometrie $7 D013053
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Zakova, Jitka $u Faculty of Military Health Sciences, University of Defense, Trebesska 1575, CZ-50001 Hradec Kralove, Czech Republic
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 21, č. 5 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33807562 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100656 $b ABA008
- 999 __
- $a ok $b bmc $g 1690016 $s 1139542
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 21 $c 5 $e 20210305 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a TH03030336 $p Technologická Agentura České Republiky
- LZP __
- $a Pubmed-20210728