Sources of inconsistency in mean mechanical response of abdominal aortic aneurysm tissue
R. Vitásek, D. Gossiho, S. Polzer
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- aneurysma břišní aorty * MeSH
- aorta abdominalis MeSH
- aorta MeSH
- biomechanika MeSH
- mechanický stres MeSH
- počítačová simulace MeSH
- prasata MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
INTRODUCTION: There is a striking difference in the reported mean response of abdominal aortic aneurysm tissue in academic literature depending on the type of tests (uniaxial vs biaxial) performed. In this paper, the hypothesis variability caused by differences in experimental protocols is explored using porcine aortic tissue as a substitute for aneurysmal tissue. METHODS: Nine samples of porcine aorta were created and both uniaxial and biaxial tests were performed. Three effects were investigated. (i) Effect of sample (non) preconditioning, (ii) effect of objective function used (normalised vs non-normalised), and (iii) effect of chosen procedure used for mean response calculation: constant averaging (CA) vs fit to averaged response (FAR) vs fit to all data (FAD). Both the overall shape of mean curve and mean initial stiffness were compared. RESULTS: (i) Non-preconditioning led to a much stiffer response, and initial stiffness was about three times higher for a non-preconditioned response based on uniaxial data compared to a preconditioned biaxial response. (ii) CA led to a much stiffer response compared to FAR and FAD procedures which gave similar results. (iii) Normalised objective function produced a mean response with six times lower initial stiffness and more pronounced nonlinearity compared to non-normalised objective function. DISCUSSION: It is possible to reproduce a mechanically inconsistent response purely by using the chosen experimental protocol. Non-preconditioned data from failure tests should be used for FE simulation of the elastic response of aneurysms. CA should not be used to obtain a mean response.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019151
- 003
- CZ-PrNML
- 005
- 20210830100729.0
- 007
- ta
- 008
- 210728s2021 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jmbbm.2020.104274 $2 doi
- 035 __
- $a (PubMed)33421951
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Vitásek, Radek $u Department of Applied Mechanics, VSB-Technical University of Ostrava, 17.listopadu 2172/15, Ostrava-Poruba, 708 00, Czech Republic. Electronic address: radek.vitasek@vsb.cz
- 245 10
- $a Sources of inconsistency in mean mechanical response of abdominal aortic aneurysm tissue / $c R. Vitásek, D. Gossiho, S. Polzer
- 520 9_
- $a INTRODUCTION: There is a striking difference in the reported mean response of abdominal aortic aneurysm tissue in academic literature depending on the type of tests (uniaxial vs biaxial) performed. In this paper, the hypothesis variability caused by differences in experimental protocols is explored using porcine aortic tissue as a substitute for aneurysmal tissue. METHODS: Nine samples of porcine aorta were created and both uniaxial and biaxial tests were performed. Three effects were investigated. (i) Effect of sample (non) preconditioning, (ii) effect of objective function used (normalised vs non-normalised), and (iii) effect of chosen procedure used for mean response calculation: constant averaging (CA) vs fit to averaged response (FAR) vs fit to all data (FAD). Both the overall shape of mean curve and mean initial stiffness were compared. RESULTS: (i) Non-preconditioning led to a much stiffer response, and initial stiffness was about three times higher for a non-preconditioned response based on uniaxial data compared to a preconditioned biaxial response. (ii) CA led to a much stiffer response compared to FAR and FAD procedures which gave similar results. (iii) Normalised objective function produced a mean response with six times lower initial stiffness and more pronounced nonlinearity compared to non-normalised objective function. DISCUSSION: It is possible to reproduce a mechanically inconsistent response purely by using the chosen experimental protocol. Non-preconditioned data from failure tests should be used for FE simulation of the elastic response of aneurysms. CA should not be used to obtain a mean response.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a aorta $7 D001011
- 650 _2
- $a aorta abdominalis $7 D001012
- 650 12
- $a aneurysma břišní aorty $7 D017544
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a prasata $7 D013552
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Gossiho, Didier $u Department of Biomedical Engineering, University of Iowa, 5605 Seamans Center, Iowa City, IA, 52242, USA
- 700 1_
- $a Polzer, Stanislav $u Department of Applied Mechanics, VSB-Technical University of Ostrava, 17.listopadu 2172/15, Ostrava-Poruba, 708 00, Czech Republic
- 773 0_
- $w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 115, č. - (2021), s. 104274
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33421951 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100729 $b ABA008
- 999 __
- $a ok $b bmc $g 1690066 $s 1139597
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 115 $c - $d 104274 $e 20201217 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
- LZP __
- $a Pubmed-20210728