Sources of inconsistency in mean mechanical response of abdominal aortic aneurysm tissue

R. Vitásek, D. Gossiho, S. Polzer

. 2021 ; 115 (-) : 104274. [pub] 20201217

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019151

INTRODUCTION: There is a striking difference in the reported mean response of abdominal aortic aneurysm tissue in academic literature depending on the type of tests (uniaxial vs biaxial) performed. In this paper, the hypothesis variability caused by differences in experimental protocols is explored using porcine aortic tissue as a substitute for aneurysmal tissue. METHODS: Nine samples of porcine aorta were created and both uniaxial and biaxial tests were performed. Three effects were investigated. (i) Effect of sample (non) preconditioning, (ii) effect of objective function used (normalised vs non-normalised), and (iii) effect of chosen procedure used for mean response calculation: constant averaging (CA) vs fit to averaged response (FAR) vs fit to all data (FAD). Both the overall shape of mean curve and mean initial stiffness were compared. RESULTS: (i) Non-preconditioning led to a much stiffer response, and initial stiffness was about three times higher for a non-preconditioned response based on uniaxial data compared to a preconditioned biaxial response. (ii) CA led to a much stiffer response compared to FAR and FAD procedures which gave similar results. (iii) Normalised objective function produced a mean response with six times lower initial stiffness and more pronounced nonlinearity compared to non-normalised objective function. DISCUSSION: It is possible to reproduce a mechanically inconsistent response purely by using the chosen experimental protocol. Non-preconditioned data from failure tests should be used for FE simulation of the elastic response of aneurysms. CA should not be used to obtain a mean response.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019151
003      
CZ-PrNML
005      
20210830100729.0
007      
ta
008      
210728s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jmbbm.2020.104274 $2 doi
035    __
$a (PubMed)33421951
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Vitásek, Radek $u Department of Applied Mechanics, VSB-Technical University of Ostrava, 17.listopadu 2172/15, Ostrava-Poruba, 708 00, Czech Republic. Electronic address: radek.vitasek@vsb.cz
245    10
$a Sources of inconsistency in mean mechanical response of abdominal aortic aneurysm tissue / $c R. Vitásek, D. Gossiho, S. Polzer
520    9_
$a INTRODUCTION: There is a striking difference in the reported mean response of abdominal aortic aneurysm tissue in academic literature depending on the type of tests (uniaxial vs biaxial) performed. In this paper, the hypothesis variability caused by differences in experimental protocols is explored using porcine aortic tissue as a substitute for aneurysmal tissue. METHODS: Nine samples of porcine aorta were created and both uniaxial and biaxial tests were performed. Three effects were investigated. (i) Effect of sample (non) preconditioning, (ii) effect of objective function used (normalised vs non-normalised), and (iii) effect of chosen procedure used for mean response calculation: constant averaging (CA) vs fit to averaged response (FAR) vs fit to all data (FAD). Both the overall shape of mean curve and mean initial stiffness were compared. RESULTS: (i) Non-preconditioning led to a much stiffer response, and initial stiffness was about three times higher for a non-preconditioned response based on uniaxial data compared to a preconditioned biaxial response. (ii) CA led to a much stiffer response compared to FAR and FAD procedures which gave similar results. (iii) Normalised objective function produced a mean response with six times lower initial stiffness and more pronounced nonlinearity compared to non-normalised objective function. DISCUSSION: It is possible to reproduce a mechanically inconsistent response purely by using the chosen experimental protocol. Non-preconditioned data from failure tests should be used for FE simulation of the elastic response of aneurysms. CA should not be used to obtain a mean response.
650    _2
$a zvířata $7 D000818
650    _2
$a aorta $7 D001011
650    _2
$a aorta abdominalis $7 D001012
650    12
$a aneurysma břišní aorty $7 D017544
650    _2
$a biomechanika $7 D001696
650    _2
$a počítačová simulace $7 D003198
650    _2
$a mechanický stres $7 D013314
650    _2
$a prasata $7 D013552
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Gossiho, Didier $u Department of Biomedical Engineering, University of Iowa, 5605 Seamans Center, Iowa City, IA, 52242, USA
700    1_
$a Polzer, Stanislav $u Department of Applied Mechanics, VSB-Technical University of Ostrava, 17.listopadu 2172/15, Ostrava-Poruba, 708 00, Czech Republic
773    0_
$w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 115, č. - (2021), s. 104274
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33421951 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830100729 $b ABA008
999    __
$a ok $b bmc $g 1690066 $s 1139597
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 115 $c - $d 104274 $e 20201217 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...