Microstructural, mechanical, in vitro corrosion and biological characterization of an extruded Zn-0.8Mg-0.2Sr (wt%) as an absorbable material
J. Čapek, J. Kubásek, J. Pinc, J. Fojt, S. Krajewski, F. Rupp, P. Li
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
- MeSH
- biokompatibilní materiály MeSH
- koroze MeSH
- pevnost v tahu MeSH
- slitiny * MeSH
- testování materiálů MeSH
- vstřebatelné implantáty MeSH
- zinek * MeSH
- Publikační typ
- časopisecké články MeSH
Zinc (Zn) alloys seem to be promising candidates for application in orthopaedic or cardiovascular medical implants. In this area, high standards are required regarding the biocompatibility as well as excellent mechanical and tailored degradation properties. In the presented study, a novel Zn-0.8Mg-0.2Sr (wt%) alloy has been fabricated by the combination of casting, homogenization annealing and extrusion at 200 °C. As a consequence of its fine-grained homogenous microstructure, the prepared material is characterized by an excellent combination of tensile yield strength, ultimate tensile strength and elongation corresponding to 244 MPa, 324 MPa and 20% respectively. The in vitro corrosion rates of the Zn-0.8Mg-0.2Sr alloy in the physiological solution and the simulated body fluid were 244 μm/a and 69.8 μm/a, respectively. Furthermore, an extract test revealed that Zn-0.8Mg-0.2Sr extracts diluted to 25% had no adverse effects towards L929 fibroblasts, TAg periosteal cells and Saos-2 osteoblasts. Moreover, the Zn-0.8Mg-0.2Sr surface showed effective inhibition of initial Streptococcus gordonii adhesion and biofilm formation. These results indicated the Zn-0.8Mg-0.2Sr alloy, which has superior mechanical properties, might be a promising candidate for materials used for load-bearing applications.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019159
- 003
- CZ-PrNML
- 005
- 20210830100734.0
- 007
- ta
- 008
- 210728s2021 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.msec.2021.111924 $2 doi
- 035 __
- $a (PubMed)33641917
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Čapek, Jaroslav $u FZU - The Institute of Physics, Czech Academy of Sciences, Na Slovance 1999/2, Prague 8 182 21, Czech Republic
- 245 10
- $a Microstructural, mechanical, in vitro corrosion and biological characterization of an extruded Zn-0.8Mg-0.2Sr (wt%) as an absorbable material / $c J. Čapek, J. Kubásek, J. Pinc, J. Fojt, S. Krajewski, F. Rupp, P. Li
- 520 9_
- $a Zinc (Zn) alloys seem to be promising candidates for application in orthopaedic or cardiovascular medical implants. In this area, high standards are required regarding the biocompatibility as well as excellent mechanical and tailored degradation properties. In the presented study, a novel Zn-0.8Mg-0.2Sr (wt%) alloy has been fabricated by the combination of casting, homogenization annealing and extrusion at 200 °C. As a consequence of its fine-grained homogenous microstructure, the prepared material is characterized by an excellent combination of tensile yield strength, ultimate tensile strength and elongation corresponding to 244 MPa, 324 MPa and 20% respectively. The in vitro corrosion rates of the Zn-0.8Mg-0.2Sr alloy in the physiological solution and the simulated body fluid were 244 μm/a and 69.8 μm/a, respectively. Furthermore, an extract test revealed that Zn-0.8Mg-0.2Sr extracts diluted to 25% had no adverse effects towards L929 fibroblasts, TAg periosteal cells and Saos-2 osteoblasts. Moreover, the Zn-0.8Mg-0.2Sr surface showed effective inhibition of initial Streptococcus gordonii adhesion and biofilm formation. These results indicated the Zn-0.8Mg-0.2Sr alloy, which has superior mechanical properties, might be a promising candidate for materials used for load-bearing applications.
- 650 _2
- $a vstřebatelné implantáty $7 D020341
- 650 12
- $a slitiny $7 D000497
- 650 _2
- $a biokompatibilní materiály $7 D001672
- 650 _2
- $a koroze $7 D003343
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a pevnost v tahu $7 D013718
- 650 12
- $a zinek $7 D015032
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kubásek, Jiří $u Institute of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 6, Prague 6, 166 28, Czech Republic
- 700 1_
- $a Pinc, Jan $u FZU - The Institute of Physics, Czech Academy of Sciences, Na Slovance 1999/2, Prague 8 182 21, Czech Republic
- 700 1_
- $a Fojt, Jaroslav $u Institute of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 6, Prague 6, 166 28, Czech Republic
- 700 1_
- $a Krajewski, Stefanie $u Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
- 700 1_
- $a Rupp, Frank $u Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
- 700 1_
- $a Li, Ping $u Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany. Electronic address: ping.li@med.uni-tuebingen.de
- 773 0_
- $w MED00184559 $t Materials science & engineering. C, Materials for biological applications $x 1873-0191 $g Roč. 122, č. - (2021), s. 111924
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33641917 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100734 $b ABA008
- 999 __
- $a ok $b bmc $g 1690074 $s 1139605
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 122 $c - $d 111924 $e 20210130 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559
- LZP __
- $a Pubmed-20210728