• Je něco špatně v tomto záznamu ?

Microstructural, mechanical, in vitro corrosion and biological characterization of an extruded Zn-0.8Mg-0.2Sr (wt%) as an absorbable material

J. Čapek, J. Kubásek, J. Pinc, J. Fojt, S. Krajewski, F. Rupp, P. Li

. 2021 ; 122 (-) : 111924. [pub] 20210130

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019159

Zinc (Zn) alloys seem to be promising candidates for application in orthopaedic or cardiovascular medical implants. In this area, high standards are required regarding the biocompatibility as well as excellent mechanical and tailored degradation properties. In the presented study, a novel Zn-0.8Mg-0.2Sr (wt%) alloy has been fabricated by the combination of casting, homogenization annealing and extrusion at 200 °C. As a consequence of its fine-grained homogenous microstructure, the prepared material is characterized by an excellent combination of tensile yield strength, ultimate tensile strength and elongation corresponding to 244 MPa, 324 MPa and 20% respectively. The in vitro corrosion rates of the Zn-0.8Mg-0.2Sr alloy in the physiological solution and the simulated body fluid were 244 μm/a and 69.8 μm/a, respectively. Furthermore, an extract test revealed that Zn-0.8Mg-0.2Sr extracts diluted to 25% had no adverse effects towards L929 fibroblasts, TAg periosteal cells and Saos-2 osteoblasts. Moreover, the Zn-0.8Mg-0.2Sr surface showed effective inhibition of initial Streptococcus gordonii adhesion and biofilm formation. These results indicated the Zn-0.8Mg-0.2Sr alloy, which has superior mechanical properties, might be a promising candidate for materials used for load-bearing applications.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019159
003      
CZ-PrNML
005      
20210830100734.0
007      
ta
008      
210728s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.msec.2021.111924 $2 doi
035    __
$a (PubMed)33641917
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Čapek, Jaroslav $u FZU - The Institute of Physics, Czech Academy of Sciences, Na Slovance 1999/2, Prague 8 182 21, Czech Republic
245    10
$a Microstructural, mechanical, in vitro corrosion and biological characterization of an extruded Zn-0.8Mg-0.2Sr (wt%) as an absorbable material / $c J. Čapek, J. Kubásek, J. Pinc, J. Fojt, S. Krajewski, F. Rupp, P. Li
520    9_
$a Zinc (Zn) alloys seem to be promising candidates for application in orthopaedic or cardiovascular medical implants. In this area, high standards are required regarding the biocompatibility as well as excellent mechanical and tailored degradation properties. In the presented study, a novel Zn-0.8Mg-0.2Sr (wt%) alloy has been fabricated by the combination of casting, homogenization annealing and extrusion at 200 °C. As a consequence of its fine-grained homogenous microstructure, the prepared material is characterized by an excellent combination of tensile yield strength, ultimate tensile strength and elongation corresponding to 244 MPa, 324 MPa and 20% respectively. The in vitro corrosion rates of the Zn-0.8Mg-0.2Sr alloy in the physiological solution and the simulated body fluid were 244 μm/a and 69.8 μm/a, respectively. Furthermore, an extract test revealed that Zn-0.8Mg-0.2Sr extracts diluted to 25% had no adverse effects towards L929 fibroblasts, TAg periosteal cells and Saos-2 osteoblasts. Moreover, the Zn-0.8Mg-0.2Sr surface showed effective inhibition of initial Streptococcus gordonii adhesion and biofilm formation. These results indicated the Zn-0.8Mg-0.2Sr alloy, which has superior mechanical properties, might be a promising candidate for materials used for load-bearing applications.
650    _2
$a vstřebatelné implantáty $7 D020341
650    12
$a slitiny $7 D000497
650    _2
$a biokompatibilní materiály $7 D001672
650    _2
$a koroze $7 D003343
650    _2
$a testování materiálů $7 D008422
650    _2
$a pevnost v tahu $7 D013718
650    12
$a zinek $7 D015032
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kubásek, Jiří $u Institute of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 6, Prague 6, 166 28, Czech Republic
700    1_
$a Pinc, Jan $u FZU - The Institute of Physics, Czech Academy of Sciences, Na Slovance 1999/2, Prague 8 182 21, Czech Republic
700    1_
$a Fojt, Jaroslav $u Institute of Metals and Corrosion Engineering, University of Chemistry and Technology, Technická 6, Prague 6, 166 28, Czech Republic
700    1_
$a Krajewski, Stefanie $u Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
700    1_
$a Rupp, Frank $u Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany
700    1_
$a Li, Ping $u Section Medical Materials Science and Technology, University Hospital Tübingen, Osianderstrasse 2-8, Tübingen 72076, Germany. Electronic address: ping.li@med.uni-tuebingen.de
773    0_
$w MED00184559 $t Materials science & engineering. C, Materials for biological applications $x 1873-0191 $g Roč. 122, č. - (2021), s. 111924
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33641917 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830100734 $b ABA008
999    __
$a ok $b bmc $g 1690074 $s 1139605
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 122 $c - $d 111924 $e 20210130 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...