Comparison of 2D OPG image versus orthopantomogram from 3D CBCT from the forensic point of view

H. Eliasova, T. Dostalova, A. Prochazka, E. Sediva, M. Horacek, P. Urbanova, P. Hlinakova

. 2021 ; 48 (-) : 101802. [pub] 20201016

Jazyk angličtina Země Irsko

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019351

Forensic dental identification has employed traditionally 2D digital radiological imaging techniques. More recently, 3D cone beam computer tomography (CBCT) data, widely applied in clinical dentistry, have been gradually used. The purpose of this study was to compare the precision and quality of 2D digital orthopantomogram (OPG) and 2D OPG images generated from cone beam computed tomography (CBCT). The study sample consisted of 50 patients with archived conventional 2D OPG and 3D CBCT images. Patients signed an informed consent form to take part in our study. Measurements of the mandible, teeth and dental restorations were taken by two observers on calibrated 2D OPG and 3D CBCT-to-OPG images using measurement functionalities of DOPLHIN software. Acquired dimensions were compared side by side and images of fillings were superimposed. For better visual comparison and more efficient image registration, the methods of spline interpolation were used. The pairs of absolute measurements obtained from conventional OPG and CBCT-to-OPG-converted images were highly correlated (p < 0.05). However, larger, and horizontally measured distances were revealed to be more affected than shorter vertically taken measurements. In relative terms, CBCT-generated width/length indices of the canines and the first molars ranged from 84% to 99.8% of those acquired from traditional OPGs. In addition, corresponding points on the teeth and fillings were compared side by side and in superimposition. The average coincidence of images was 6.1%. The results revealed that for selected metric variables 2D OPGs and 3D CBCT-generated OPGs were complementary and could be used for forensic comparisons.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019351
003      
CZ-PrNML
005      
20210830100924.0
007      
ta
008      
210728s2021 ie f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.legalmed.2020.101802 $2 doi
035    __
$a (PubMed)33478657
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ie
100    1_
$a Eliasova, Hana $u Institute of Criminalistics, Police of the Czech Republic, Strojnická 27, 170 89 Prague, Czech Republic. Electronic address: hanaeliasova@atlas.cz
245    10
$a Comparison of 2D OPG image versus orthopantomogram from 3D CBCT from the forensic point of view / $c H. Eliasova, T. Dostalova, A. Prochazka, E. Sediva, M. Horacek, P. Urbanova, P. Hlinakova
520    9_
$a Forensic dental identification has employed traditionally 2D digital radiological imaging techniques. More recently, 3D cone beam computer tomography (CBCT) data, widely applied in clinical dentistry, have been gradually used. The purpose of this study was to compare the precision and quality of 2D digital orthopantomogram (OPG) and 2D OPG images generated from cone beam computed tomography (CBCT). The study sample consisted of 50 patients with archived conventional 2D OPG and 3D CBCT images. Patients signed an informed consent form to take part in our study. Measurements of the mandible, teeth and dental restorations were taken by two observers on calibrated 2D OPG and 3D CBCT-to-OPG images using measurement functionalities of DOPLHIN software. Acquired dimensions were compared side by side and images of fillings were superimposed. For better visual comparison and more efficient image registration, the methods of spline interpolation were used. The pairs of absolute measurements obtained from conventional OPG and CBCT-to-OPG-converted images were highly correlated (p < 0.05). However, larger, and horizontally measured distances were revealed to be more affected than shorter vertically taken measurements. In relative terms, CBCT-generated width/length indices of the canines and the first molars ranged from 84% to 99.8% of those acquired from traditional OPGs. In addition, corresponding points on the teeth and fillings were compared side by side and in superimposition. The average coincidence of images was 6.1%. The results revealed that for selected metric variables 2D OPGs and 3D CBCT-generated OPGs were complementary and could be used for forensic comparisons.
650    _2
$a počítačová tomografie s kuželovým svazkem $x metody $7 D054893
650    _2
$a trvalá zubní náhrada $7 D003793
650    12
$a soudní stomatologie $x metody $7 D005553
650    _2
$a lidé $7 D006801
650    _2
$a mandibula $7 D008334
650    _2
$a digitální zubní radiografie $x metody $7 D019252
650    _2
$a rentgendiagnostika panoramatická $x metody $7 D011862
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a zuby $7 D014070
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Dostalova, Tatjana $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: tatjana.dostalova@fnmotol.cz
700    1_
$a Prochazka, Ales $u University of Chemistry and Technology Prague, Department of Computing and Control Engineering, Technicka 5, 166 28 Prague 6, Czech Republic. Electronic address: A.Prochazka@ieee.org
700    1_
$a Sediva, Eliska $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: eliska.sediva@fnmotol.cz
700    1_
$a Horacek, Martin $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: martin.horacek@fnmotol.cz
700    1_
$a Urbanova, Petra $u Masaryk University, Faculty of Science, Department of Anthropology, Kotlarska 2, 611 37 Brno, Czech Republic. Electronic address: urbanova@sci.muni.cz
700    1_
$a Hlinakova, Petra $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: petra.hlinakova@fnmotol.cz
773    0_
$w MED00008702 $t Legal medicine (Tokyo, Japan) $x 1873-4162 $g Roč. 48, č. - (2021), s. 101802
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33478657 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830100924 $b ABA008
999    __
$a ok $b bmc $g 1690226 $s 1139797
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 48 $c - $d 101802 $e 20201016 $i 1873-4162 $m Legal medicine $n Leg Med $x MED00008702
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...