Comparison of 2D OPG image versus orthopantomogram from 3D CBCT from the forensic point of view
H. Eliasova, T. Dostalova, A. Prochazka, E. Sediva, M. Horacek, P. Urbanova, P. Hlinakova
Jazyk angličtina Země Irsko
Typ dokumentu srovnávací studie, časopisecké články
- MeSH
- digitální zubní radiografie metody MeSH
- lidé MeSH
- mandibula MeSH
- počítačová tomografie s kuželovým svazkem metody MeSH
- rentgendiagnostika panoramatická metody MeSH
- senzitivita a specificita MeSH
- soudní stomatologie * metody MeSH
- trvalá zubní náhrada MeSH
- zuby MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
Forensic dental identification has employed traditionally 2D digital radiological imaging techniques. More recently, 3D cone beam computer tomography (CBCT) data, widely applied in clinical dentistry, have been gradually used. The purpose of this study was to compare the precision and quality of 2D digital orthopantomogram (OPG) and 2D OPG images generated from cone beam computed tomography (CBCT). The study sample consisted of 50 patients with archived conventional 2D OPG and 3D CBCT images. Patients signed an informed consent form to take part in our study. Measurements of the mandible, teeth and dental restorations were taken by two observers on calibrated 2D OPG and 3D CBCT-to-OPG images using measurement functionalities of DOPLHIN software. Acquired dimensions were compared side by side and images of fillings were superimposed. For better visual comparison and more efficient image registration, the methods of spline interpolation were used. The pairs of absolute measurements obtained from conventional OPG and CBCT-to-OPG-converted images were highly correlated (p < 0.05). However, larger, and horizontally measured distances were revealed to be more affected than shorter vertically taken measurements. In relative terms, CBCT-generated width/length indices of the canines and the first molars ranged from 84% to 99.8% of those acquired from traditional OPGs. In addition, corresponding points on the teeth and fillings were compared side by side and in superimposition. The average coincidence of images was 6.1%. The results revealed that for selected metric variables 2D OPGs and 3D CBCT-generated OPGs were complementary and could be used for forensic comparisons.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019351
- 003
- CZ-PrNML
- 005
- 20210830100924.0
- 007
- ta
- 008
- 210728s2021 ie f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.legalmed.2020.101802 $2 doi
- 035 __
- $a (PubMed)33478657
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ie
- 100 1_
- $a Eliasova, Hana $u Institute of Criminalistics, Police of the Czech Republic, Strojnická 27, 170 89 Prague, Czech Republic. Electronic address: hanaeliasova@atlas.cz
- 245 10
- $a Comparison of 2D OPG image versus orthopantomogram from 3D CBCT from the forensic point of view / $c H. Eliasova, T. Dostalova, A. Prochazka, E. Sediva, M. Horacek, P. Urbanova, P. Hlinakova
- 520 9_
- $a Forensic dental identification has employed traditionally 2D digital radiological imaging techniques. More recently, 3D cone beam computer tomography (CBCT) data, widely applied in clinical dentistry, have been gradually used. The purpose of this study was to compare the precision and quality of 2D digital orthopantomogram (OPG) and 2D OPG images generated from cone beam computed tomography (CBCT). The study sample consisted of 50 patients with archived conventional 2D OPG and 3D CBCT images. Patients signed an informed consent form to take part in our study. Measurements of the mandible, teeth and dental restorations were taken by two observers on calibrated 2D OPG and 3D CBCT-to-OPG images using measurement functionalities of DOPLHIN software. Acquired dimensions were compared side by side and images of fillings were superimposed. For better visual comparison and more efficient image registration, the methods of spline interpolation were used. The pairs of absolute measurements obtained from conventional OPG and CBCT-to-OPG-converted images were highly correlated (p < 0.05). However, larger, and horizontally measured distances were revealed to be more affected than shorter vertically taken measurements. In relative terms, CBCT-generated width/length indices of the canines and the first molars ranged from 84% to 99.8% of those acquired from traditional OPGs. In addition, corresponding points on the teeth and fillings were compared side by side and in superimposition. The average coincidence of images was 6.1%. The results revealed that for selected metric variables 2D OPGs and 3D CBCT-generated OPGs were complementary and could be used for forensic comparisons.
- 650 _2
- $a počítačová tomografie s kuželovým svazkem $x metody $7 D054893
- 650 _2
- $a trvalá zubní náhrada $7 D003793
- 650 12
- $a soudní stomatologie $x metody $7 D005553
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mandibula $7 D008334
- 650 _2
- $a digitální zubní radiografie $x metody $7 D019252
- 650 _2
- $a rentgendiagnostika panoramatická $x metody $7 D011862
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a zuby $7 D014070
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Dostalova, Tatjana $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: tatjana.dostalova@fnmotol.cz
- 700 1_
- $a Prochazka, Ales $u University of Chemistry and Technology Prague, Department of Computing and Control Engineering, Technicka 5, 166 28 Prague 6, Czech Republic. Electronic address: A.Prochazka@ieee.org
- 700 1_
- $a Sediva, Eliska $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: eliska.sediva@fnmotol.cz
- 700 1_
- $a Horacek, Martin $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: martin.horacek@fnmotol.cz
- 700 1_
- $a Urbanova, Petra $u Masaryk University, Faculty of Science, Department of Anthropology, Kotlarska 2, 611 37 Brno, Czech Republic. Electronic address: urbanova@sci.muni.cz
- 700 1_
- $a Hlinakova, Petra $u Department of Stomatology, Charles University, 2nd Medical Faculty and Motol University Hospital, V Uvalu 84, 150 06 Prague, Czech Republic. Electronic address: petra.hlinakova@fnmotol.cz
- 773 0_
- $w MED00008702 $t Legal medicine (Tokyo, Japan) $x 1873-4162 $g Roč. 48, č. - (2021), s. 101802
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33478657 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830100924 $b ABA008
- 999 __
- $a ok $b bmc $g 1690226 $s 1139797
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 48 $c - $d 101802 $e 20201016 $i 1873-4162 $m Legal medicine $n Leg Med $x MED00008702
- LZP __
- $a Pubmed-20210728