The effect of albumin and γ-globulin on synovial fluid lubrication: Implication for knee joint replacements

D. Nečas, K. Sadecká, M. Vrbka, A. Galandáková, MA. Wimmer, J. Gallo, M. Hartl

. 2021 ; 113 (-) : 104117. [pub] 20200928

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019560

Total knee arthroplasty has become a routine procedure for patients suffering from joint diseases. Although the number of operations continuously increases, a limited service-life of implants represents a persisting challenge for scientists. Understanding of lubrication may help to suitably explain tribological processes on the way to replacements that become durable well into the third decade of service. The aim of the present study is to assess the formation of protein lubricating film in the knee implant. A developed knee simulator was used to observe the contact of real femoral and transparent polymer tibial component using fluorescent microscopy. The contact was lubricated by various protein solutions with attention to the behaviour of albumin and γ-globulin. In order to suitably mimic a human synovial fluid, hyaluronic acid and phospholipids were subsequently added to the solutions. Further, the change in shape and the migration of the contact zone were studied. The results showed considerable appearance differences of the contact over the swing phase of the simplified gait cycle. Regarding film formation, a strong interaction of the various molecules of synovial fluid was observed. It was found that the thickness of the lubricating layer stabilizes within around 50 s. Throughout the contact zone, protein agglomerations were present and could be clearly visualised using the applied optical technique.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019560
003      
CZ-PrNML
005      
20210830101144.0
007      
ta
008      
210728s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jmbbm.2020.104117 $2 doi
035    __
$a (PubMed)33065468
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Nečas, D $u Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic. Electronic address: david.necas@vut.cz
245    14
$a The effect of albumin and γ-globulin on synovial fluid lubrication: Implication for knee joint replacements / $c D. Nečas, K. Sadecká, M. Vrbka, A. Galandáková, MA. Wimmer, J. Gallo, M. Hartl
520    9_
$a Total knee arthroplasty has become a routine procedure for patients suffering from joint diseases. Although the number of operations continuously increases, a limited service-life of implants represents a persisting challenge for scientists. Understanding of lubrication may help to suitably explain tribological processes on the way to replacements that become durable well into the third decade of service. The aim of the present study is to assess the formation of protein lubricating film in the knee implant. A developed knee simulator was used to observe the contact of real femoral and transparent polymer tibial component using fluorescent microscopy. The contact was lubricated by various protein solutions with attention to the behaviour of albumin and γ-globulin. In order to suitably mimic a human synovial fluid, hyaluronic acid and phospholipids were subsequently added to the solutions. Further, the change in shape and the migration of the contact zone were studied. The results showed considerable appearance differences of the contact over the swing phase of the simplified gait cycle. Regarding film formation, a strong interaction of the various molecules of synovial fluid was observed. It was found that the thickness of the lubricating layer stabilizes within around 50 s. Throughout the contact zone, protein agglomerations were present and could be clearly visualised using the applied optical technique.
650    _2
$a albuminy $7 D000418
650    12
$a totální endoprotéza kolene $7 D019645
650    _2
$a lidé $7 D006801
650    _2
$a kolenní kloub $7 D007719
650    _2
$a lubrikace $7 D008153
650    12
$a synoviální tekutina $7 D013582
650    _2
$a gama-globuliny $7 D005719
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Sadecká, K $u Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic
700    1_
$a Vrbka, M $u Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic
700    1_
$a Galandáková, A $u Dept of Medical Chemistry and Biochemistry, Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
700    1_
$a Wimmer, M A $u Dept of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
700    1_
$a Gallo, J $u Dept of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, University Hospital Olomouc, Czech Republic
700    1_
$a Hartl, M $u Dept of Tribology, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic
773    0_
$w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 113, č. - (2021), s. 104117
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33065468 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830101145 $b ABA008
999    __
$a ok $b bmc $g 1690401 $s 1140006
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 113 $c - $d 104117 $e 20200928 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace