-
Je něco špatně v tomto záznamu ?
Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses
J. Lenčo, T. Šemlej, MA. Khalikova, I. Fabrik, F. Švec
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- chromatografie kapalinová MeSH
- proteiny MeSH
- proteomika * MeSH
- tandemová hmotnostní spektrometrie * MeSH
- teplota MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Elevated column temperature represents a simple means for improving chromatographic separation of peptides. Here, we demonstrated the advantages of the column temperature in peptide separation using state-of-the-art columns. More importantly, we also determined how temperature can impair proteomic bottom-up analyses. We found that an elevated temperature in combination with the acidic pH of the mobile phase induced in-column peptide hydrolysis with high specificity to Asp and accelerated five modification reactions of amino acids. The positive effects of temperature dominated in the 30 min long gradients since the column operated at 90 °C provided the largest number of identified peptides and proteins. However, the adverse effects of temperature on peptide integrity in longer liquid chromatography-mass spectrometry (LC-MS) analyses required its reduction to obtain optimum results. The largest number of peptides was identified using the column maintained at 75 °C in 60 min long gradients, at 60 °C in 120 min long gradients, and at 45 °C in 240 min long gradients. Our results indicate that no universal column temperature exists for bottom-up LC-MS analyses. Quite the contrary, the temperature setting must be selected rationally to exploit the full capabilities of the state-of-the-art mass spectrometers in proteomic LC-MS analyses, with the gradient time being a critical factor.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21019564
- 003
- CZ-PrNML
- 005
- 20210830101147.0
- 007
- ta
- 008
- 210728s2021 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1021/acs.jproteome.0c00479 $2 doi
- 035 __
- $a (PubMed)33085896
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Lenčo, Juraj $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
- 245 10
- $a Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses / $c J. Lenčo, T. Šemlej, MA. Khalikova, I. Fabrik, F. Švec
- 520 9_
- $a Elevated column temperature represents a simple means for improving chromatographic separation of peptides. Here, we demonstrated the advantages of the column temperature in peptide separation using state-of-the-art columns. More importantly, we also determined how temperature can impair proteomic bottom-up analyses. We found that an elevated temperature in combination with the acidic pH of the mobile phase induced in-column peptide hydrolysis with high specificity to Asp and accelerated five modification reactions of amino acids. The positive effects of temperature dominated in the 30 min long gradients since the column operated at 90 °C provided the largest number of identified peptides and proteins. However, the adverse effects of temperature on peptide integrity in longer liquid chromatography-mass spectrometry (LC-MS) analyses required its reduction to obtain optimum results. The largest number of peptides was identified using the column maintained at 75 °C in 60 min long gradients, at 60 °C in 120 min long gradients, and at 45 °C in 240 min long gradients. Our results indicate that no universal column temperature exists for bottom-up LC-MS analyses. Quite the contrary, the temperature setting must be selected rationally to exploit the full capabilities of the state-of-the-art mass spectrometers in proteomic LC-MS analyses, with the gradient time being a critical factor.
- 650 _2
- $a chromatografie kapalinová $7 D002853
- 650 _2
- $a proteiny $7 D011506
- 650 12
- $a proteomika $7 D040901
- 650 12
- $a tandemová hmotnostní spektrometrie $7 D053719
- 650 _2
- $a teplota $7 D013696
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šemlej, Tomáš $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
- 700 1_
- $a Khalikova, Maria A $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
- 700 1_
- $a Fabrik, Ivo $u Biomedical Research Center, University Hospital Hradec Králové, Sokolská 581, 500 05 Hradec Králové, Czech Republic
- 700 1_
- $a Švec, František $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
- 773 0_
- $w MED00166892 $t Journal of proteome research $x 1535-3907 $g Roč. 20, č. 1 (2021), s. 420-432
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33085896 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830101147 $b ABA008
- 999 __
- $a ok $b bmc $g 1690405 $s 1140010
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 20 $c 1 $d 420-432 $e 20201021 $i 1535-3907 $m Journal of proteome research $n J Proteome Res $x MED00166892
- LZP __
- $a Pubmed-20210728