• Je něco špatně v tomto záznamu ?

Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses

J. Lenčo, T. Šemlej, MA. Khalikova, I. Fabrik, F. Švec

. 2021 ; 20 (1) : 420-432. [pub] 20201021

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc21019564

Elevated column temperature represents a simple means for improving chromatographic separation of peptides. Here, we demonstrated the advantages of the column temperature in peptide separation using state-of-the-art columns. More importantly, we also determined how temperature can impair proteomic bottom-up analyses. We found that an elevated temperature in combination with the acidic pH of the mobile phase induced in-column peptide hydrolysis with high specificity to Asp and accelerated five modification reactions of amino acids. The positive effects of temperature dominated in the 30 min long gradients since the column operated at 90 °C provided the largest number of identified peptides and proteins. However, the adverse effects of temperature on peptide integrity in longer liquid chromatography-mass spectrometry (LC-MS) analyses required its reduction to obtain optimum results. The largest number of peptides was identified using the column maintained at 75 °C in 60 min long gradients, at 60 °C in 120 min long gradients, and at 45 °C in 240 min long gradients. Our results indicate that no universal column temperature exists for bottom-up LC-MS analyses. Quite the contrary, the temperature setting must be selected rationally to exploit the full capabilities of the state-of-the-art mass spectrometers in proteomic LC-MS analyses, with the gradient time being a critical factor.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21019564
003      
CZ-PrNML
005      
20210830101147.0
007      
ta
008      
210728s2021 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1021/acs.jproteome.0c00479 $2 doi
035    __
$a (PubMed)33085896
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Lenčo, Juraj $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
245    10
$a Sense and Nonsense of Elevated Column Temperature in Proteomic Bottom-up LC-MS Analyses / $c J. Lenčo, T. Šemlej, MA. Khalikova, I. Fabrik, F. Švec
520    9_
$a Elevated column temperature represents a simple means for improving chromatographic separation of peptides. Here, we demonstrated the advantages of the column temperature in peptide separation using state-of-the-art columns. More importantly, we also determined how temperature can impair proteomic bottom-up analyses. We found that an elevated temperature in combination with the acidic pH of the mobile phase induced in-column peptide hydrolysis with high specificity to Asp and accelerated five modification reactions of amino acids. The positive effects of temperature dominated in the 30 min long gradients since the column operated at 90 °C provided the largest number of identified peptides and proteins. However, the adverse effects of temperature on peptide integrity in longer liquid chromatography-mass spectrometry (LC-MS) analyses required its reduction to obtain optimum results. The largest number of peptides was identified using the column maintained at 75 °C in 60 min long gradients, at 60 °C in 120 min long gradients, and at 45 °C in 240 min long gradients. Our results indicate that no universal column temperature exists for bottom-up LC-MS analyses. Quite the contrary, the temperature setting must be selected rationally to exploit the full capabilities of the state-of-the-art mass spectrometers in proteomic LC-MS analyses, with the gradient time being a critical factor.
650    _2
$a chromatografie kapalinová $7 D002853
650    _2
$a proteiny $7 D011506
650    12
$a proteomika $7 D040901
650    12
$a tandemová hmotnostní spektrometrie $7 D053719
650    _2
$a teplota $7 D013696
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Šemlej, Tomáš $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
700    1_
$a Khalikova, Maria A $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
700    1_
$a Fabrik, Ivo $u Biomedical Research Center, University Hospital Hradec Králové, Sokolská 581, 500 05 Hradec Králové, Czech Republic
700    1_
$a Švec, František $u Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05 Hradec Králové, Czech Republic
773    0_
$w MED00166892 $t Journal of proteome research $x 1535-3907 $g Roč. 20, č. 1 (2021), s. 420-432
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33085896 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830101147 $b ABA008
999    __
$a ok $b bmc $g 1690405 $s 1140010
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 20 $c 1 $d 420-432 $e 20201021 $i 1535-3907 $m Journal of proteome research $n J Proteome Res $x MED00166892
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...