• Je něco špatně v tomto záznamu ?

Torus obstacle method as a wrapping approach of the deltoid muscle group for humeral abduction in musculoskeletal simulation

M. Aurbach, J. Špička, F. Süß, J. Vychytil, L. Havelková, T. Ryba, S. Dendorfer

. 2020 ; 109 (-) : 109864. [pub] 20200601

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc21020236
E-zdroje Online Plný text

NLK ProQuest Central od 2003-01-01 do Před 2 měsíci
Health & Medicine (ProQuest) od 2003-01-01 do Před 2 měsíci

Musculoskeletal models of the shoulder complex are valuable research aids to investigate tears of the supraspinatus and the resulting mechanical impact during abduction of the humerus. One of the major contributors to this motion is the deltoid muscle group and for this, an accurate modeling of the lines of action is indispensable. The aim of this work was to utilize a torus obstacle wrapping approach for the deltoids of an existing shoulder model and assess the feasibility of the approach during humeral abduction. The shoulder model from the AnyBody™ modeling system was used as a platform. The size of the tori is based on a magnetic resonance imaging (MRI) approach and several kinematic couplings are implemented to determine the trajectories of the tori during abduction. To assess the model behavior, the moment arms of the virtual muscle elements and the resultant glenohumeral joint reaction force (GHJF) were compared with reference data from the literature during abduction of the humerus in the range 20°-120°. The root mean square error for the anterior, lateral and posterior part between the simulated muscle elements and reference data from the literature was 3.9, 1.7 and 5.8 mm, respectively. The largest deviation occurred on the outer elements of the muscle groups, with 12.6, 10.4 and 20.5 mm, respectively. During abduction, there is no overlapping of the muscle elements and these are in continuous contact with the torus obstacles, thus enabling a continuous force transmission. This results in a rising trend of the resultant GHJF. The torus obstacle approach as a wrapping method for the deltoid muscles provides a guided muscle pathing by simultaneously approximating the curvature of the deltoid muscle. The results from the comparison of the simulated moment arms and the resultant GHJF are in accordance with those in the literature in the range 20°-120° of abduction. Although this study shows the strength of the torus obstacle as a wrapping approach, the method of fitting the tori according to MRI data was not suitable. A cadaver study is recommended to better validate and mathematically describe the torus approach.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21020236
003      
CZ-PrNML
005      
20210830101844.0
007      
ta
008      
210728s2020 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jbiomech.2020.109864 $2 doi
035    __
$a (PubMed)32807304
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Aurbach, M $u Laboratory for Biomechanics, Ostbayerische Technische Hochschule (OTH) Regensburg, Regensburg, Germany
245    10
$a Torus obstacle method as a wrapping approach of the deltoid muscle group for humeral abduction in musculoskeletal simulation / $c M. Aurbach, J. Špička, F. Süß, J. Vychytil, L. Havelková, T. Ryba, S. Dendorfer
520    9_
$a Musculoskeletal models of the shoulder complex are valuable research aids to investigate tears of the supraspinatus and the resulting mechanical impact during abduction of the humerus. One of the major contributors to this motion is the deltoid muscle group and for this, an accurate modeling of the lines of action is indispensable. The aim of this work was to utilize a torus obstacle wrapping approach for the deltoids of an existing shoulder model and assess the feasibility of the approach during humeral abduction. The shoulder model from the AnyBody™ modeling system was used as a platform. The size of the tori is based on a magnetic resonance imaging (MRI) approach and several kinematic couplings are implemented to determine the trajectories of the tori during abduction. To assess the model behavior, the moment arms of the virtual muscle elements and the resultant glenohumeral joint reaction force (GHJF) were compared with reference data from the literature during abduction of the humerus in the range 20°-120°. The root mean square error for the anterior, lateral and posterior part between the simulated muscle elements and reference data from the literature was 3.9, 1.7 and 5.8 mm, respectively. The largest deviation occurred on the outer elements of the muscle groups, with 12.6, 10.4 and 20.5 mm, respectively. During abduction, there is no overlapping of the muscle elements and these are in continuous contact with the torus obstacles, thus enabling a continuous force transmission. This results in a rising trend of the resultant GHJF. The torus obstacle approach as a wrapping method for the deltoid muscles provides a guided muscle pathing by simultaneously approximating the curvature of the deltoid muscle. The results from the comparison of the simulated moment arms and the resultant GHJF are in accordance with those in the literature in the range 20°-120° of abduction. Although this study shows the strength of the torus obstacle as a wrapping approach, the method of fitting the tori according to MRI data was not suitable. A cadaver study is recommended to better validate and mathematically describe the torus approach.
650    _2
$a biomechanika $7 D001696
650    12
$a musculus deltoideus $7 D057645
650    _2
$a humerus $7 D006811
650    _2
$a rozsah kloubních pohybů $7 D016059
650    _2
$a rotátorová manžeta $7 D017006
650    12
$a ramenní kloub $7 D012785
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Špička, J $u Man-Machine Interaction Department, New Technologies - Research Center, University of West Bohemia in Pilsen, Univerzitní 8, 301 00 Pilsen, Czech Republic
700    1_
$a Süß, F $u Laboratory for Biomechanics, Ostbayerische Technische Hochschule (OTH) Regensburg, Regensburg, Germany
700    1_
$a Vychytil, J $u Man-Machine Interaction Department, New Technologies - Research Center, University of West Bohemia in Pilsen, Univerzitní 8, 301 00 Pilsen, Czech Republic
700    1_
$a Havelková, L $u Man-Machine Interaction Department, New Technologies - Research Center, University of West Bohemia in Pilsen, Univerzitní 8, 301 00 Pilsen, Czech Republic
700    1_
$a Ryba, T $u Faculty of Applied Sciences, University of West Bohemia in Pilsen, Univerzitní 8, 301 00 Pilsen, Czech Republic
700    1_
$a Dendorfer, S $u Laboratory for Biomechanics, Ostbayerische Technische Hochschule (OTH) Regensburg, Regensburg, Germany; Regensburg Center for Biomedical Engineering, University and OTH Regensburg, Germany
773    0_
$w MED00002553 $t Journal of biomechanics $x 1873-2380 $g Roč. 109, č. - (2020), s. 109864
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32807304 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20210728 $b ABA008
991    __
$a 20210830101844 $b ABA008
999    __
$a ok $b bmc $g 1690925 $s 1140682
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 109 $c - $d 109864 $e 20200601 $i 1873-2380 $m Journal of biomechanics $n J Biomech $x MED00002553
LZP    __
$a Pubmed-20210728

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace