-
Je něco špatně v tomto záznamu ?
Standardization of patient modeling in hyperthermia simulation studies: introducing the Erasmus Virtual Patient Repository
GG. Bellizzi, K. Sumser, I. VilasBoas-Ribeiro, S. Curto, T. Drizdal, GC. van Rhoon, M. Franckena, MM. Paulides
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2019
Taylor & Francis Open Access
od 2018-05-03
Taylor & Francis Open Access
od 2019-01-01
Medline Complete (EBSCOhost)
od 1999-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1985
- MeSH
- hlava MeSH
- hypertermie * MeSH
- indukovaná hypertermie * MeSH
- lidé MeSH
- počítačová simulace MeSH
- referenční standardy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Purpose: Thermal dose-effect relations have demonstrated that clinical effectiveness of hyperthermia would benefit from more controlled heating of the tumor. Hyperthermia treatment planning (HTP) is a potent tool to study strategies enabling target conformal heating, but its accuracy is affected by patient modeling approximations. Homogeneous phantoms models are being used that do not match the body shape of patients in treatment position and often have unrealistic target volumes. As a consequence, simulation accuracy is affected, and performance comparisons are difficult. The aim of this study is to provide the first step toward standardization of HTP simulation studies in terms of patient modeling by introducing the Erasmus Virtual Patient Repository (EVPR): a virtual patient model database.Methods: Four patients with a tumor in the head and neck or the pelvis region were selected, and corresponding models were created using a clinical segmentation procedure. Using the Erasmus University Medical Center standard procedure, HTP was applied to these models and compared to HTP for commonly used surrogate models.Results: Although this study was aimed at presenting the EVPR database, our study illustrates that there is a non-negligible difference in the predicted SAR patterns between patient models and homogeneous phantom-based surrogate models. We further demonstrate the difference between actual and simplified target volumes being used today.Conclusion: Our study describes the EVPR for the research community as a first step toward standardization of hyperthermia simulation studies.
Department of Biomedical Technology Czech Technical University Prague Prague Czech Republic
Department of Electrical Engineering Eindhoven University of Technology Eindhoven The Netherlands
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21020816
- 003
- CZ-PrNML
- 005
- 20210830102446.0
- 007
- ta
- 008
- 210728s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1080/02656736.2020.1772996 $2 doi
- 035 __
- $a (PubMed)32515240
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Bellizzi, Gennaro G $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
- 245 10
- $a Standardization of patient modeling in hyperthermia simulation studies: introducing the Erasmus Virtual Patient Repository / $c GG. Bellizzi, K. Sumser, I. VilasBoas-Ribeiro, S. Curto, T. Drizdal, GC. van Rhoon, M. Franckena, MM. Paulides
- 520 9_
- $a Purpose: Thermal dose-effect relations have demonstrated that clinical effectiveness of hyperthermia would benefit from more controlled heating of the tumor. Hyperthermia treatment planning (HTP) is a potent tool to study strategies enabling target conformal heating, but its accuracy is affected by patient modeling approximations. Homogeneous phantoms models are being used that do not match the body shape of patients in treatment position and often have unrealistic target volumes. As a consequence, simulation accuracy is affected, and performance comparisons are difficult. The aim of this study is to provide the first step toward standardization of HTP simulation studies in terms of patient modeling by introducing the Erasmus Virtual Patient Repository (EVPR): a virtual patient model database.Methods: Four patients with a tumor in the head and neck or the pelvis region were selected, and corresponding models were created using a clinical segmentation procedure. Using the Erasmus University Medical Center standard procedure, HTP was applied to these models and compared to HTP for commonly used surrogate models.Results: Although this study was aimed at presenting the EVPR database, our study illustrates that there is a non-negligible difference in the predicted SAR patterns between patient models and homogeneous phantom-based surrogate models. We further demonstrate the difference between actual and simplified target volumes being used today.Conclusion: Our study describes the EVPR for the research community as a first step toward standardization of hyperthermia simulation studies.
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a hlava $7 D006257
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a hypertermie $7 D000084462
- 650 12
- $a indukovaná hypertermie $7 D006979
- 650 _2
- $a referenční standardy $7 D012015
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Sumser, Kemal $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
- 700 1_
- $a VilasBoas-Ribeiro, Iva $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
- 700 1_
- $a Curto, Sergio $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
- 700 1_
- $a Drizdal, Tomas $u Department of Biomedical Technology, Czech Technical University in Prague, Prague, Czech Republic
- 700 1_
- $a van Rhoon, Gerard C $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
- 700 1_
- $a Franckena, Martine $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands
- 700 1_
- $a Paulides, Margarethus M $u Hyperthermia Unit, Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, The Netherlands $u Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
- 773 0_
- $w MED00002331 $t International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group $x 1464-5157 $g Roč. 37, č. 1 (2020), s. 608-616
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32515240 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210728 $b ABA008
- 991 __
- $a 20210830102446 $b ABA008
- 999 __
- $a ok $b bmc $g 1691407 $s 1141262
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 37 $c 1 $d 608-616 $e - $i 1464-5157 $m International journal of hyperthermia $n Int J Hyperthermia $x MED00002331
- LZP __
- $a Pubmed-20210728