Cord Blood Extracellular Vesicles Analyzed by Flow Cytometry with Thresholding Using 405 nm or 488 nm Laser Leads to Concurrent Results

K. Pekárková, J. Soukup, M. Kostelanská, J. Širc, Z. Straňák, K. Holada

. 2021 ; 11 (8) : . [pub] 20210722

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21024326

Grantová podpora
NV17-31403A MZ0 CEP - Centrální evidence projektů
1322119 Grantová Agentura, Univerzita Karlova

Extracellular vesicles (EVs) from liquid biopsies are extensively analyzed by flow cytometry, a technology that is continuously evolving. Thresholding utilizing a violet 405 nm laser side scatter (VSSC) has recently been implemented. Here, we collected set of large EV (lEV) samples from cord blood, which we analyzed using a standard flow cytometer improved via a 405 nm laser side scatter. Samples were analyzed using two distinct thresholding methods-one based on VSSC, and one based on VSSC combined with fluorescence thresholding on stained phosphatidylserine. Through these thresholding methods, we compared lEVs from pre-term births and control cord blood. Double-labeled lEVs with platelet CD36+/CD41+, activated platelet CD41+/CD62P+ and endothelial CD31+/CD105+ antibodies were used. Apart from comparing the two groups together, we also correlated measured lEVs with the thresholding methods. We also correlated the results of this study with data analyzed in our previous study in which we used a conventional 488 nm laser SSC. We did not find any difference between the two cord blood groups. However, we found highly concurrent data via our correlation of the thresholding methods, with correlation coefficients ranging from 0.80 to 0.96 even though the numbers of detected lEVs differed between thresholding methods. In conclusion, our approaches to thresholding provided concurrent data and it seems that improving the cytometer with the use of a VSSC increases its sensitivity, despite not being particularly critical to the validity of flow cytometric studies that compare pathological and physiological conditions in liquid biopsies.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21024326
003      
CZ-PrNML
005      
20220509175931.0
007      
ta
008      
211006s2021 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/diagnostics11081320 $2 doi
035    __
$a (PubMed)34441255
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Pekárková, Kristýna $u Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University, 128 00 Prague, Czech Republic
245    10
$a Cord Blood Extracellular Vesicles Analyzed by Flow Cytometry with Thresholding Using 405 nm or 488 nm Laser Leads to Concurrent Results / $c K. Pekárková, J. Soukup, M. Kostelanská, J. Širc, Z. Straňák, K. Holada
520    9_
$a Extracellular vesicles (EVs) from liquid biopsies are extensively analyzed by flow cytometry, a technology that is continuously evolving. Thresholding utilizing a violet 405 nm laser side scatter (VSSC) has recently been implemented. Here, we collected set of large EV (lEV) samples from cord blood, which we analyzed using a standard flow cytometer improved via a 405 nm laser side scatter. Samples were analyzed using two distinct thresholding methods-one based on VSSC, and one based on VSSC combined with fluorescence thresholding on stained phosphatidylserine. Through these thresholding methods, we compared lEVs from pre-term births and control cord blood. Double-labeled lEVs with platelet CD36+/CD41+, activated platelet CD41+/CD62P+ and endothelial CD31+/CD105+ antibodies were used. Apart from comparing the two groups together, we also correlated measured lEVs with the thresholding methods. We also correlated the results of this study with data analyzed in our previous study in which we used a conventional 488 nm laser SSC. We did not find any difference between the two cord blood groups. However, we found highly concurrent data via our correlation of the thresholding methods, with correlation coefficients ranging from 0.80 to 0.96 even though the numbers of detected lEVs differed between thresholding methods. In conclusion, our approaches to thresholding provided concurrent data and it seems that improving the cytometer with the use of a VSSC increases its sensitivity, despite not being particularly critical to the validity of flow cytometric studies that compare pathological and physiological conditions in liquid biopsies.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Soukup, Jakub $u Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University, 128 00 Prague, Czech Republic $u Department of Genetics and Microbiology, Faculty of Science, Charles University, 128 44 Prague, Czech Republic
700    1_
$a Kostelanská, Marie $u Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University, 128 00 Prague, Czech Republic
700    1_
$a Širc, Jan $u The Institute for the Care of Mother and Child, 147 00 Prague, Czech Republic
700    1_
$a Straňák, Zbyněk $u The Institute for the Care of Mother and Child, 147 00 Prague, Czech Republic
700    1_
$a Holada, Karel $u Institute of Immunology and Microbiology, First Faculty of Medicine, Charles University, 128 00 Prague, Czech Republic
773    0_
$w MED00195450 $t Diagnostics (Basel, Switzerland) $x 2075-4418 $g Roč. 11, č. 8 (2021)
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20211006 $b ABA008
991    __
$a 20220509175929 $b ABA008
999    __
$a ind $b bmc $g 1708279 $s 1144823
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 11 $c 8 $e 20210722 $i 2075-4418 $m Diagnostics $n Diagnostics $x MED00195450
GRA    __
$a NV17-31403A $p MZ0
GRA    __
$a 1322119 $p Grantová Agentura, Univerzita Karlova
LZP    __
$a Pubmed-20211006

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace