Je něco špatně v tomto záznamu ?
Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes
M. Pásek, J. Šimurda, M. Bébarová, G. Christé
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Free Medical Journals
od 1966 do Před 6 měsíci
Open Access Digital Library
od 1853-01-01
Open Access Digital Library
od 1853-01-01
PubMed
34313306
DOI
10.1242/jcs.258228
Knihovny.cz E-zdroje
- MeSH
- kardiomyocyty * metabolismus MeSH
- krysa rodu rattus MeSH
- pumpa pro výměnu sodíku a vápníku MeSH
- sarkolema metabolismus MeSH
- sodík metabolismus MeSH
- srdeční komory metabolismus MeSH
- vápník * metabolismus MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The ratio between Na+-Ca2+ exchange current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes (JNaCa-ratio) estimated from electrophysiological data published to date yields strikingly different values between 1.7 and nearly 40. Possible reasons for such divergence were analysed by Monte Carlo simulations assuming both normal and log-normal distribution of the measured data. The confidence intervals CI95 of the mean JNaCa-ratios computed from the reported data showed an overlap of values between 1 and 3, and between 0.3 and 4.3 in the case of normal and log-normal distribution, respectively. Further analyses revealed that the published high values likely result from a large scatter of data due to transmural differences in JNaCa, dispersion of cell membrane capacitances and variability in incomplete detubulation. Taking into account the asymmetric distribution of the measured data, the reduction of mean current densities after detubulation and the substantially smaller CI95 of lower values of the mean JNaCa-ratio, the values between 1.6 and 3.2 may be considered as the most accurate estimates. This implies that 40 to 60% of Na+-Ca2+ exchanger is located at the t-tubular membrane of adult rat ventricular cardiomyocytes.
Institute of Thermomechanics Czech Academy of Science Dolejškova 5 182 00 Prague Czech Republic
Laboratoire de Neurocardiologie EA4612 Université Lyon 1 Lyon F 69003 France
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21025350
- 003
- CZ-PrNML
- 005
- 20211026133910.0
- 007
- ta
- 008
- 211013s2021 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1242/jcs.258228 $2 doi
- 035 __
- $a (PubMed)34313306
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Pásek, Michal $u Institute of Thermomechanics, Czech Academy of Science, Dolejškova 5, 182 00, Prague, Czech Republic $u Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- 245 10
- $a Divergent estimates of the ratio between Na+-Ca2+ current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes / $c M. Pásek, J. Šimurda, M. Bébarová, G. Christé
- 520 9_
- $a The ratio between Na+-Ca2+ exchange current densities in t-tubular and surface membranes of rat ventricular cardiomyocytes (JNaCa-ratio) estimated from electrophysiological data published to date yields strikingly different values between 1.7 and nearly 40. Possible reasons for such divergence were analysed by Monte Carlo simulations assuming both normal and log-normal distribution of the measured data. The confidence intervals CI95 of the mean JNaCa-ratios computed from the reported data showed an overlap of values between 1 and 3, and between 0.3 and 4.3 in the case of normal and log-normal distribution, respectively. Further analyses revealed that the published high values likely result from a large scatter of data due to transmural differences in JNaCa, dispersion of cell membrane capacitances and variability in incomplete detubulation. Taking into account the asymmetric distribution of the measured data, the reduction of mean current densities after detubulation and the substantially smaller CI95 of lower values of the mean JNaCa-ratio, the values between 1.6 and 3.2 may be considered as the most accurate estimates. This implies that 40 to 60% of Na+-Ca2+ exchanger is located at the t-tubular membrane of adult rat ventricular cardiomyocytes.
- 650 _2
- $a zvířata $7 D000818
- 650 12
- $a vápník $x metabolismus $7 D002118
- 650 _2
- $a srdeční komory $x metabolismus $7 D006352
- 650 12
- $a kardiomyocyty $x metabolismus $7 D032383
- 650 _2
- $a krysa rodu Rattus $7 D051381
- 650 _2
- $a sarkolema $x metabolismus $7 D012508
- 650 _2
- $a sodík $x metabolismus $7 D012964
- 650 _2
- $a pumpa pro výměnu sodíku a vápníku $7 D019831
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šimurda, Jiří $u Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- 700 1_
- $a Bébarová, Markéta $u Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
- 700 1_
- $a Christé, Georges $u Laboratoire de Neurocardiologie, EA4612, Université Lyon 1, Lyon F-69003, France
- 773 0_
- $w MED00002576 $t Journal of cell science $x 1477-9137 $g Roč. 134, č. 14 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34313306 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20211013 $b ABA008
- 991 __
- $a 20211026133916 $b ABA008
- 999 __
- $a ok $b bmc $g 1714409 $s 1145857
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 134 $c 14 $e 20210727 $i 1477-9137 $m Journal of cell science $n J Cell Sci $x MED00002576
- LZP __
- $a Pubmed-20211013