Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Real-time quality control of nuchal translucency measurements using the exponentially weighted moving average chart

M. Hynek, J. Zvárová, D. Smetanová, D. Stejskal, J. Kalina

. 2021 ; 60 (1) : 84-89. [pub] -

Jazyk angličtina Země Čína

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21026311

OBJECTIVE: The establishment of ongoing audits for first-trimester nuchal translucency (NT) measurements is of paramount importance. The exponentially weighted moving average (EWMA) chart has been published as an efficient tool for NT quality control with the advantages of being suitable for real-time long-term monitoring. This study aimed to assess the efficacy of real-time NT quality control using EWMA charts. MATERIALS AND METHODS: This was an ongoing prospective study conducted from January 2011 to December 2017 at the Centre for Fetal Medicine Gennet in Prague. The quality of NT measurements was assessed using the NT retrospective distribution parameters and EWMA charts, and the results were presented to the sonographers during collective meetings. RESULTS: Overall, 28,928 NT measurements obtained from six sonographers were eligible for the study. Looking at individual EWMA charts, we observed four main outcomes. First, there was a clear improvement in the performance of sonographers with initially poor performances. Second, the performance of sonographers with an initially satisfactory quality was maintained. Third, there was an observed deterioration of the performance without the audits. Last, the sonographers appreciated an unequivocal and straightforward graphical presentation of EWMA curves. CONCLUSION: EWMA proved to be an efficient and suitable tool for real-time monitoring of NT quality and led to an overall improvement of the sonographers' performance.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21026311
003      
CZ-PrNML
005      
20211026133016.0
007      
ta
008      
211013s2021 cc f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.tjog.2020.11.012 $2 doi
035    __
$a (PubMed)33495014
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a cc
100    1_
$a Hynek, Martin $u Gennet, Centre for Fetal Medicine and Reproductive Genetics, Prague, Czech Republic; Department of Gynecology and Obstetrics, Thomayer Hospital, Prague, Czech Republic. Electronic address: martin.hynek@gmail.com
245    10
$a Real-time quality control of nuchal translucency measurements using the exponentially weighted moving average chart / $c M. Hynek, J. Zvárová, D. Smetanová, D. Stejskal, J. Kalina
520    9_
$a OBJECTIVE: The establishment of ongoing audits for first-trimester nuchal translucency (NT) measurements is of paramount importance. The exponentially weighted moving average (EWMA) chart has been published as an efficient tool for NT quality control with the advantages of being suitable for real-time long-term monitoring. This study aimed to assess the efficacy of real-time NT quality control using EWMA charts. MATERIALS AND METHODS: This was an ongoing prospective study conducted from January 2011 to December 2017 at the Centre for Fetal Medicine Gennet in Prague. The quality of NT measurements was assessed using the NT retrospective distribution parameters and EWMA charts, and the results were presented to the sonographers during collective meetings. RESULTS: Overall, 28,928 NT measurements obtained from six sonographers were eligible for the study. Looking at individual EWMA charts, we observed four main outcomes. First, there was a clear improvement in the performance of sonographers with initially poor performances. Second, the performance of sonographers with an initially satisfactory quality was maintained. Third, there was an observed deterioration of the performance without the audits. Last, the sonographers appreciated an unequivocal and straightforward graphical presentation of EWMA curves. CONCLUSION: EWMA proved to be an efficient and suitable tool for real-time monitoring of NT quality and led to an overall improvement of the sonographers' performance.
650    _2
$a interpretace statistických dat $7 D003627
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a měření nuchální translucence $x normy $7 D048208
650    _2
$a těhotenství $7 D011247
650    _2
$a první trimestr těhotenství $7 D011261
650    _2
$a prospektivní studie $7 D011446
650    12
$a řízení kvality $7 D011786
650    _2
$a referenční standardy $7 D012015
650    _2
$a retrospektivní studie $7 D012189
655    _2
$a časopisecké články $7 D016428
700    1_
$a Zvárová, Jana $u The Czech Academy of Sciences, Institute of Computer Science, Prague, Czech Republic; Institute of Hygiene and Epidemiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
700    1_
$a Smetanová, Dagmar $u Gennet, Centre for Fetal Medicine and Reproductive Genetics, Prague, Czech Republic
700    1_
$a Stejskal, David $u Gennet, Centre for Fetal Medicine and Reproductive Genetics, Prague, Czech Republic
700    1_
$a Kalina, Jan $u The Czech Academy of Sciences, Institute of Computer Science, Prague, Czech Republic
773    0_
$w MED00167593 $t Taiwanese journal of obstetrics & gynecology $x 1875-6263 $g Roč. 60, č. 1 (2021), s. 84-89
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33495014 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20211013 $b ABA008
991    __
$a 20211026133022 $b ABA008
999    __
$a ok $b bmc $g 1715127 $s 1146818
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 60 $c 1 $d 84-89 $e - $i 1875-6263 $m Taiwanese journal of obstetrics and gynecology $n Taiwan J Obstet Gynecol $x MED00167593
LZP    __
$a Pubmed-20211013

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...