Je něco špatně v tomto záznamu ?
A Successful Case of TKA With Complex Deformity And Retained Hardware Using Computer Navigation
J. Cerny, J. Soukup, T. Novotny
Jazyk angličtina Země Spojené státy americké
Typ dokumentu kazuistiky
NLK
Directory of Open Access Journals
od 2015
PubMed Central
od 2015
Europe PubMed Central
od 2015
Open Access Digital Library
od 2015-03-01
ROAD: Directory of Open Access Scholarly Resources
od 2015
- Publikační typ
- kazuistiky MeSH
We present a case report of a 60-year-old Caucasian female patient, who had undergone a series of procedures for a periprosthetic (after total hip arthroplasty) Vancouver C type diaphyseal fracture of the right femur (reverse distal femoral locking compression plate [LCP] osteosynthesis, then a corrective osteotomy with another distal femoral LCP osteosynthesis). Subsequently, she developed high-grade osteoarthrosis of the right knee, indicated for a total knee arthroplasty. Considering the extent of previous procedures, which had significantly compromised the bone quality of the femur and therefore increased the risk of a refracture after an eventual hardware removal, we decided to retain the LCP plate. We concluded that the optimal solution would be the use of a computer-navigated total knee arthroplasty. This procedure obviated the need for intramedullary guiding, while ensuring optimal joint alignment. No postoperative complications emerged.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22001066
- 003
- CZ-PrNML
- 005
- 20250610091615.0
- 007
- ta
- 008
- 220107e20211210xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.artd.2021.11.005 $2 doi
- 035 __
- $a (PubMed)34917718
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Cerny, Jan $u Department of Orthopaedics, University J.E. Purkinje, Masaryk Hospital, Usti nad Labem, Czech Republic
- 245 12
- $a A Successful Case of TKA With Complex Deformity And Retained Hardware Using Computer Navigation / $c J. Cerny, J. Soukup, T. Novotny
- 520 9_
- $a We present a case report of a 60-year-old Caucasian female patient, who had undergone a series of procedures for a periprosthetic (after total hip arthroplasty) Vancouver C type diaphyseal fracture of the right femur (reverse distal femoral locking compression plate [LCP] osteosynthesis, then a corrective osteotomy with another distal femoral LCP osteosynthesis). Subsequently, she developed high-grade osteoarthrosis of the right knee, indicated for a total knee arthroplasty. Considering the extent of previous procedures, which had significantly compromised the bone quality of the femur and therefore increased the risk of a refracture after an eventual hardware removal, we decided to retain the LCP plate. We concluded that the optimal solution would be the use of a computer-navigated total knee arthroplasty. This procedure obviated the need for intramedullary guiding, while ensuring optimal joint alignment. No postoperative complications emerged.
- 655 _2
- $a kazuistiky $7 D002363
- 700 1_
- $a Soukup, Jan $u Department of Orthopaedics, University J.E. Purkinje, Masaryk Hospital, Usti nad Labem, Czech Republic $7 xx0329001
- 700 1_
- $a Novotný, Tomáš $u Department of Orthopaedics, University J.E. Purkinje, Masaryk Hospital, Usti nad Labem, Czech Republic $7 xx0264903
- 773 0_
- $w MED00207995 $t Arthroplasty today $x 2352-3441 $g Roč. 13 (20211210), s. 29-34
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34917718 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20220107 $b ABA008
- 991 __
- $a 20250610091608 $b ABA008
- 999 __
- $a ind $b bmc $g 1745348 $s 1152213
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 13 $c - $d 29-34 $e 20211210 $i 2352-3441 $m Arthroplasty today $n Arthroplast Today $x MED00207995
- LZP __
- $a Pubmed-20220107