Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Effectiveness of dentin pre-treatment on bond strength of two self-adhesive resin cements compared to an etch-and-rinse system: an in vitro study

M. Hammal, Z. Chlup, T. Ingr, J. Staněk, R. Mounajjed

. 2021 ; 9 (-) : e11736. [pub] 20211026

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22001460

Statement of problem: It has been shown that selective etching improves the bond strength of some self-adhesive resin cements to enamel. The same has yet to be determined with dentin pre-treatment. Purpose: To evaluate the tensile bond strength of two self-adhesive resin cements after two dentin surface pre-treatments, and also to analyze the cement/dentin interface. Material and Methods: One hundred and twelve human third molars were extracted. The teeth were distributed into seven groups (n = 16). Maxcem Elite Chroma (MAX) (Kerr, Scafati, Italy) and Relyx U200 (RLX) (3M ESPE, Neuss, Germany) were used without pre-treatment or with two dentin pre-treatments (polyacrylic acid or phosphoric acid). A conventional etch-and-rinse (EAR) luting cement, NX3 Nexus (NX3) (Kerr, Scafati, Italy), was used as an external control group. Before testing, all specimens were stored in distilled water for 24 hours. Three specimens from each group were prepared for scanning electron microscopy observation (SEM). A tensile bond strength test (TBS) was performed for the remaining samples. The data were statistically analyzed using the Kruskal-Wallis test and Pairwise comparisons using the Wilcoxon rank sum test. Results: MAX without pre-treatment and with phosphoric acid etching attained statistically similar bond strengths to NX3 (P > 0.05). There was a statistical difference (P = 0.00488) between RLX without pre-treatment (5.62 MPa) and NX3 (10.88 MPa). Phosphoric acid pre-treatment increases the bond strength values of RLX to a strength that is comparable to NX3 (P > 0.05). The lowest tensile bond strength (TBS) was attained after the application of polyacrylic acid with MAX (1.98 MPa). No statistical differences were found between the RLX bond strength values after polyacrylic acid treatment and RLX without pre-treatment or NX3 (P > 0.05). SEM observations disclosed an enhanced potential of the self-adhesive cements to infiltrate into dentin tubules and form resin tags when applied after phosphoric acid pre-treatment. The failure mode was dominantly adhesive. Conclusions: On dentin, the self-adhesive resin cement MAX might be an effective alternative to conventional resin cement. Etching the dentin with phosphoric acid does not have a negative effect on the bond strength of MAX to dentin. On the other hand, phosphoric acid improved the bond strength of RLX when compared to EAR cement.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22001460
003      
CZ-PrNML
005      
20220112153612.0
007      
ta
008      
220107s2021 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.7717/peerj.11736 $2 doi
035    __
$a (PubMed)34754615
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Hammal, Milad $u Institute of Dentistry and Oral Sciences, Palacký University, Olomouc, Czech Republic
245    10
$a Effectiveness of dentin pre-treatment on bond strength of two self-adhesive resin cements compared to an etch-and-rinse system: an in vitro study / $c M. Hammal, Z. Chlup, T. Ingr, J. Staněk, R. Mounajjed
520    9_
$a Statement of problem: It has been shown that selective etching improves the bond strength of some self-adhesive resin cements to enamel. The same has yet to be determined with dentin pre-treatment. Purpose: To evaluate the tensile bond strength of two self-adhesive resin cements after two dentin surface pre-treatments, and also to analyze the cement/dentin interface. Material and Methods: One hundred and twelve human third molars were extracted. The teeth were distributed into seven groups (n = 16). Maxcem Elite Chroma (MAX) (Kerr, Scafati, Italy) and Relyx U200 (RLX) (3M ESPE, Neuss, Germany) were used without pre-treatment or with two dentin pre-treatments (polyacrylic acid or phosphoric acid). A conventional etch-and-rinse (EAR) luting cement, NX3 Nexus (NX3) (Kerr, Scafati, Italy), was used as an external control group. Before testing, all specimens were stored in distilled water for 24 hours. Three specimens from each group were prepared for scanning electron microscopy observation (SEM). A tensile bond strength test (TBS) was performed for the remaining samples. The data were statistically analyzed using the Kruskal-Wallis test and Pairwise comparisons using the Wilcoxon rank sum test. Results: MAX without pre-treatment and with phosphoric acid etching attained statistically similar bond strengths to NX3 (P > 0.05). There was a statistical difference (P = 0.00488) between RLX without pre-treatment (5.62 MPa) and NX3 (10.88 MPa). Phosphoric acid pre-treatment increases the bond strength values of RLX to a strength that is comparable to NX3 (P > 0.05). The lowest tensile bond strength (TBS) was attained after the application of polyacrylic acid with MAX (1.98 MPa). No statistical differences were found between the RLX bond strength values after polyacrylic acid treatment and RLX without pre-treatment or NX3 (P > 0.05). SEM observations disclosed an enhanced potential of the self-adhesive cements to infiltrate into dentin tubules and form resin tags when applied after phosphoric acid pre-treatment. The failure mode was dominantly adhesive. Conclusions: On dentin, the self-adhesive resin cement MAX might be an effective alternative to conventional resin cement. Etching the dentin with phosphoric acid does not have a negative effect on the bond strength of MAX to dentin. On the other hand, phosphoric acid improved the bond strength of RLX when compared to EAR cement.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Chlup, Zdeněk $u Academy of Science of the Czech Republic, Institute of Physics of Materials, Brno, Czech Republic
700    1_
$a Ingr, Tomáš $u Faculty of Science, Department of Experimental Physics, Palacký University, Olomouc, Czech Republic
700    1_
$a Staněk, Ján $u Institute of Dentistry and Oral Sciences, Palacký University, Olomouc, Czech Republic
700    1_
$a Mounajjed, Radek $u Institute of Dentistry and Oral Sciences, Palacký University, Olomouc, Czech Republic $u DCM Clinic, Hradec Kralove, Czech Republic
773    0_
$w MED00184567 $t PeerJ $x 2167-8359 $g Roč. 9, č. - (2021), s. e11736
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34754615 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20220107 $b ABA008
991    __
$a 20220112153608 $b ABA008
999    __
$a ind $b bmc $g 1745488 $s 1152607
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 9 $c - $d e11736 $e 20211026 $i 2167-8359 $m PeerJ $n PeerJ $x MED00184567
LZP    __
$a Pubmed-20220107

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...