A novel temperature-controlled open source microcontroller based sampler for collection of exhaled breath condensate in point-of-care diagnostics

V. Dosedělová, F. Foret, M. Doubková, K. Brat, P. Kubáň

. 2022 ; 237 (-) : 122984. [pub] 20211020

Language English Country Netherlands

Document type Journal Article

Exhaled breath condensate (EBC) is an attractive, non-invasive sample for clinical diagnostics. During EBC collection, its composition is influenced by the collection temperature, a factor that is often not thoroughly monitored and controlled. In this study, we assembled a novel, simple, portable, and inexpensive device for EBC collection, able to maintain a stable temperature at any value between -7 °C and +12 °C. The temperature was controlled using a microcontroller and a thermoelectric cooler that was employed to cool the aluminum block holding the glass tube or the polypropylene syringe. The performance of the novel sampler was compared with the passively cooled RTube™ and a simple EBC sampler, in which the temperature was steadily increasing during sampling. The developed sampler was able to maintain a stable temperature within ±1 °C. To investigate the influence of different sampling temperatures (i.e., +12, -7, -80 °C) on the analyte content in EBC, inorganic ions and organic acids were analyzed by capillary electrophoresis with a capacitively coupled contactless conductivity detector. It was shown that the concentration of metabolites decreased significantly with decreasing temperature. The portability and the ability to keep a stable temperature during EBC sampling makes the developed sampler suitable for point-of-care diagnostics.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22002967
003      
CZ-PrNML
005      
20220127150750.0
007      
ta
008      
220113s2022 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2021.122984 $2 doi
035    __
$a (PubMed)34736704
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Dosedělová, Věra $u Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967/97, 60200, Brno, Czech Republic; Central European Institute of Technology and Faculty of Science, Masaryk University, Kamenice 5, 62500, Brno, Czech Republic
245    12
$a A novel temperature-controlled open source microcontroller based sampler for collection of exhaled breath condensate in point-of-care diagnostics / $c V. Dosedělová, F. Foret, M. Doubková, K. Brat, P. Kubáň
520    9_
$a Exhaled breath condensate (EBC) is an attractive, non-invasive sample for clinical diagnostics. During EBC collection, its composition is influenced by the collection temperature, a factor that is often not thoroughly monitored and controlled. In this study, we assembled a novel, simple, portable, and inexpensive device for EBC collection, able to maintain a stable temperature at any value between -7 °C and +12 °C. The temperature was controlled using a microcontroller and a thermoelectric cooler that was employed to cool the aluminum block holding the glass tube or the polypropylene syringe. The performance of the novel sampler was compared with the passively cooled RTube™ and a simple EBC sampler, in which the temperature was steadily increasing during sampling. The developed sampler was able to maintain a stable temperature within ±1 °C. To investigate the influence of different sampling temperatures (i.e., +12, -7, -80 °C) on the analyte content in EBC, inorganic ions and organic acids were analyzed by capillary electrophoresis with a capacitively coupled contactless conductivity detector. It was shown that the concentration of metabolites decreased significantly with decreasing temperature. The portability and the ability to keep a stable temperature during EBC sampling makes the developed sampler suitable for point-of-care diagnostics.
650    _2
$a biologické markery $7 D015415
650    12
$a dechové testy $7 D001944
650    _2
$a elektroforéza kapilární $7 D019075
650    12
$a vydechnutí $7 D045853
650    _2
$a point of care testing $7 D000067716
650    _2
$a teplota $7 D013696
655    _2
$a časopisecké články $7 D016428
700    1_
$a Foret, František $u Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967/97, 60200, Brno, Czech Republic
700    1_
$a Doubková, Martina $u Department of Respiratory Diseases, University Hospital Brno and Faculty of Medicine, Masaryk University, Jihlavská 340/20, 625 00, Brno, Czech Republic
700    1_
$a Brat, Kristián $u Department of Respiratory Diseases, University Hospital Brno and Faculty of Medicine, Masaryk University, Jihlavská 340/20, 625 00, Brno, Czech Republic
700    1_
$a Kubáň, Petr $u Department of Bioanalytical Instrumentation, Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967/97, 60200, Brno, Czech Republic. Electronic address: petr.kuban@iach.cz
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 237, č. - (2022), s. 122984
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34736704 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127150746 $b ABA008
999    __
$a ok $b bmc $g 1750683 $s 1154116
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 237 $c - $d 122984 $e 20211020 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20220113

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...