• Something wrong with this record ?

Volatile free liquid membranes for electromembrane extraction

A. Šlampová, P. Kubáň

. 2021 ; 1182 (-) : 338959. [pub] 20210816

Language English Country Netherlands

Document type Journal Article

Volatile solvents are excellent extraction media for liquid-liquid extractions. However, their use in supported liquid membranes (SLMs) is limited by their evaporation from SLM and thus poor SLM stability and they have never been considered truly useful for electromembrane extraction (EME). In this contribution, volatile solvents were systematically investigated as liquid membranes for EME and their extraction characteristics were comprehensively examined for the first time. A short plug of a water immiscible volatile solvent (a free liquid membrane (FLM)) was sandwiched between two aqueous plugs (donor and acceptor solutions) in a narrow-bore polymeric tubing. Evaporation of the volatile FLM was thus completely avoided and excellent stability of the phase interface was ensured. Suitability of volatile FLMs for EMEs was justified by μ-EMEs of nortriptyline, haloperidol, loperamide and papaverine as model non-polar basic drugs. Extraction performance of μ-EME through ethyl acetate was comparable or better to that through standard non-volatile EME solvents and a high extraction selectivity was achieved for nortriptyline and haloperidol extracted through chloroform. μ-EMEs through the volatile FLMs were characterized by high extraction recoveries (62%-99% for standards and 40-89% for body fluids), low electric currents (10-1380 nA), no susceptibility to matrix ions and suitability for pretreatment of raw body fluids (human urine and serum). Resulting extracts were analysed by capillary electrophoresis with ultraviolet detection (CE/UV). Repeatability of the μ-EME-CE/UV method was excellent with intra-day and inter-day RSD values 0.8-3.2% and 1.8-4.6%, respectively. Further experiments demonstrated additional advantages of volatile FLMs by nearly exhaustive μ-EMEs of atenolol as the polar basic drug with no need for FLM modification by ionic carriers. The presented comprehensive examination of volatile solvents has broadened the range of liquid membranes suitable for EME and it is believed that this proof-of-concept study will stimulate further interest in a deeper investigation of volatile phase interfaces in EME.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22003453
003      
CZ-PrNML
005      
20220127150221.0
007      
ta
008      
220113s2021 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.aca.2021.338959 $2 doi
035    __
$a (PubMed)34602190
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Šlampová, Andrea $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
245    10
$a Volatile free liquid membranes for electromembrane extraction / $c A. Šlampová, P. Kubáň
520    9_
$a Volatile solvents are excellent extraction media for liquid-liquid extractions. However, their use in supported liquid membranes (SLMs) is limited by their evaporation from SLM and thus poor SLM stability and they have never been considered truly useful for electromembrane extraction (EME). In this contribution, volatile solvents were systematically investigated as liquid membranes for EME and their extraction characteristics were comprehensively examined for the first time. A short plug of a water immiscible volatile solvent (a free liquid membrane (FLM)) was sandwiched between two aqueous plugs (donor and acceptor solutions) in a narrow-bore polymeric tubing. Evaporation of the volatile FLM was thus completely avoided and excellent stability of the phase interface was ensured. Suitability of volatile FLMs for EMEs was justified by μ-EMEs of nortriptyline, haloperidol, loperamide and papaverine as model non-polar basic drugs. Extraction performance of μ-EME through ethyl acetate was comparable or better to that through standard non-volatile EME solvents and a high extraction selectivity was achieved for nortriptyline and haloperidol extracted through chloroform. μ-EMEs through the volatile FLMs were characterized by high extraction recoveries (62%-99% for standards and 40-89% for body fluids), low electric currents (10-1380 nA), no susceptibility to matrix ions and suitability for pretreatment of raw body fluids (human urine and serum). Resulting extracts were analysed by capillary electrophoresis with ultraviolet detection (CE/UV). Repeatability of the μ-EME-CE/UV method was excellent with intra-day and inter-day RSD values 0.8-3.2% and 1.8-4.6%, respectively. Further experiments demonstrated additional advantages of volatile FLMs by nearly exhaustive μ-EMEs of atenolol as the polar basic drug with no need for FLM modification by ionic carriers. The presented comprehensive examination of volatile solvents has broadened the range of liquid membranes suitable for EME and it is believed that this proof-of-concept study will stimulate further interest in a deeper investigation of volatile phase interfaces in EME.
650    _2
$a elektřina $7 D004560
650    _2
$a elektroforéza kapilární $7 D019075
650    _2
$a lidé $7 D006801
650    12
$a membrány umělé $7 D008567
650    12
$a léčivé přípravky $7 D004364
650    _2
$a rozpouštědla $7 D012997
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kubáň, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic. Electronic address: kuban@iach.cz
773    0_
$w MED00000332 $t Analytica chimica acta $x 1873-4324 $g Roč. 1182, č. - (2021), s. 338959
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34602190 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127150218 $b ABA008
999    __
$a ok $b bmc $g 1751032 $s 1154602
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 1182 $c - $d 338959 $e 20210816 $i 1873-4324 $m Analytica chimica acta $n Anal. chim. acta (Print) $x MED00000332
LZP    __
$a Pubmed-20220113

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...