The number of lymphocytes increases in the periprosthetic tissues with increasing time of implant service in non-metal-on-metal total joint arthroplasties: A role of metallic particles
M. Hobza, D. Milde, Z. Slobodova, J. Gallo
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
Grantová podpora
NV16-31852A
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 1998
Medline Complete (EBSCOhost)
od 2007-06-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
32435063
DOI
10.5507/bp.2020.019
Knihovny.cz E-zdroje
- MeSH
- kovy MeSH
- kyčelní protézy * MeSH
- lidé MeSH
- lymfocyty MeSH
- náhrada kyčelního kloubu * MeSH
- polyethyleny MeSH
- protézy - design MeSH
- reoperace MeSH
- selhání protézy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The objective of the study was to determine the association between periprosthetic concentrations of selected metals and changes induced in periprosthetic tissues (PT). METHODS: PT from 24 patients with metal-on-polyethylene or ceramic-on-polyethylene total joint replacements (TJRs) were examined. Samples underwent histological examination including quantification of cellular populations. Determination of metals was performed according to the published methodology. Results were processed using correlation analysis and Principal Component Analysis (PCA), respectively. RESULTS: Growing concentration of metals in the PT was found as a function of length of exposure (LoE). Differences in Ti, Co, Cr and V concentrations (per α = 0.05) depended on the type of alloy the implants were made from. On the contrary, the implant composition did not reflect in the different numbers of immune cells per 1 high power field, not even in distribution of the membrane type according to the Krenn classification. PCA revealed several clusters in dependence on the LoE, type of the membrane and presence of immune cells. High representation of lymphocytes in the PT was typical for clusters with the longest LoE while a higher representation of neutrophils was typical for a shorter time to reoperation. CONCLUSIONS: Correlation between the LoE and concentrations of metals in its surroundings was demonstrated. However, the tissue image analysis cannot differentiate finer, potentially metal-induced tissue changes. Importantly, the tissues become more similar with an increasing LoE. We draw a conclusion about predominantly non-specific stimulation of the PT jointly by metal and polyethylene particles in non-metal-on-metal TJRs.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22007899
- 003
- CZ-PrNML
- 005
- 20220328105734.0
- 007
- ta
- 008
- 220309s2021 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.5507/bp.2020.019 $2 doi
- 035 __
- $a (PubMed)32435063
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Hobza, Martin $7 xx0254100 $u Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00, Olomouc, Czech Republic
- 245 14
- $a The number of lymphocytes increases in the periprosthetic tissues with increasing time of implant service in non-metal-on-metal total joint arthroplasties: A role of metallic particles / $c M. Hobza, D. Milde, Z. Slobodova, J. Gallo
- 504 __
- $a Literatura
- 520 9_
- $a BACKGROUND: The objective of the study was to determine the association between periprosthetic concentrations of selected metals and changes induced in periprosthetic tissues (PT). METHODS: PT from 24 patients with metal-on-polyethylene or ceramic-on-polyethylene total joint replacements (TJRs) were examined. Samples underwent histological examination including quantification of cellular populations. Determination of metals was performed according to the published methodology. Results were processed using correlation analysis and Principal Component Analysis (PCA), respectively. RESULTS: Growing concentration of metals in the PT was found as a function of length of exposure (LoE). Differences in Ti, Co, Cr and V concentrations (per α = 0.05) depended on the type of alloy the implants were made from. On the contrary, the implant composition did not reflect in the different numbers of immune cells per 1 high power field, not even in distribution of the membrane type according to the Krenn classification. PCA revealed several clusters in dependence on the LoE, type of the membrane and presence of immune cells. High representation of lymphocytes in the PT was typical for clusters with the longest LoE while a higher representation of neutrophils was typical for a shorter time to reoperation. CONCLUSIONS: Correlation between the LoE and concentrations of metals in its surroundings was demonstrated. However, the tissue image analysis cannot differentiate finer, potentially metal-induced tissue changes. Importantly, the tissues become more similar with an increasing LoE. We draw a conclusion about predominantly non-specific stimulation of the PT jointly by metal and polyethylene particles in non-metal-on-metal TJRs.
- 650 12
- $a náhrada kyčelního kloubu $7 D019644
- 650 12
- $a kyčelní protézy $7 D006622
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lymfocyty $7 D008214
- 650 _2
- $a kovy $7 D008670
- 650 _2
- $a polyethyleny $7 D011095
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a selhání protézy $7 D011475
- 650 _2
- $a reoperace $7 D012086
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Milde, David, $d 1973- $7 ola2002157911 $u Department of Analytical Chemistry, Faculty of Science, Palacky University Olomouc, 17. listopadu 12, 771 46 Olomouc, Czech Republic
- 700 1_
- $a Slobodová, Zuzana $7 xx0139283 $u Department of Clinical and Molecular Pathology, Faculty of Medicine and Dentistry, Palacky University Olomouc, Hnevotinska 3, Olomouc, Czech Republic
- 700 1_
- $a Gallo, Jiří $7 xx0019005 $u Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital Olomouc, I. P. Pavlova 6, 779 00, Olomouc, Czech Republic
- 773 0_
- $w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia $x 1213-8118 $g Roč. 165, č. 4 (2021), s. 416-427
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32435063 $y Pubmed
- 910 __
- $a ABA008 $b A 1502 $c 958 $y p $z 0
- 990 __
- $a 20220309 $b ABA008
- 991 __
- $a 20220328105732 $b ABA008
- 999 __
- $a ok $b bmc $g 1773029 $s 1159092
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 165 $c 4 $d 416-427 $e 20200518 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
- GRA __
- $a NV16-31852A $p MZ0
- LZP __
- $b NLK118 $a Pubmed-20220309