The Agreement of a Two- and a Three-Dimensional Speckle-Tracking Global Longitudinal Strain

J. Plášek, T. Rychlý, D. Drieniková, O. Cisovský, T. Grézl, M. Homza, J. Václavík

. 2022 ; 11 (9) : . [pub] 20220425

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22017317

Grantová podpora
SGS01/LF/2020 University of Ostrava
MH CZ - DRO (FNOs/2021) Ministry of Health

BACKGROUND: Two-dimensional (2D) and three-dimensional (3D) speckle-tracking echocardiography (STE) enables assessment of myocardial function. Here, we examined the agreement between 2D and 3D STE measurement of a global longitudinal strain (GLS) in patients with normal left ventricle, reduced ejection fraction, and cardiac pacing. METHODS: Our analysis included 90 consecutive patients (59% males; average age: 73.2 ± 11.2 years) examined between May 2019-December 2020, with valid 2D and 3D loops for further speckle-tracking strain analysis. Linear regression, Pearson correlation, and a Bland-Altman plot were used to quantify the association between 2D and 3D GLS and related segments, using the 17-segment American Heart Association (AHA) model. Analyses were performed in the entire study group and subgroups. Intra- and inter-observer variability of 2D and 3D GLS measurement was also performed in all participants. RESULTS: We observed a strong correlation between 2D and 3D GLS measurements (R = 0.76, p < 0.001), which was higher in males (R = 0.78, p < 0.001) than females (R = 0.69, p < 0.001). Associated segment correlation was poor (R = 0.2-0.5, p < 0.01). The correlation between 2D and 3D GLS was weaker in individuals with ventricular pacing of >50% (R = 0.62, p < 0.001) than <50% (R = 0.8, p < 0.001), and in patients with LVEF of <35% (R = 0.69, p = 0.002) than >35% (R = 0.72, p < 0.001). Intra-observer variability for 2D and 3D GLS was 2 and 2.3%, respectively. Inter-observer variability for 2D and 3D GLS was 3.8 and 3.6%, respectively Conclusion: Overall 2D and 3D GLS were closely associated but not when analyzed per segment. It seems that GLS comparison is more representative of global shortening than local displacement. Right ventricular pacing and reduced left ventricular ejection fraction were associated with a reduced correlation between 2D and 3D GLS.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22017317
003      
CZ-PrNML
005      
20230314111713.0
007      
ta
008      
220718s2022 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/jcm11092402 $2 doi
035    __
$a (PubMed)35566528
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Plášek, Jiří $u Department of Internal Medicine and Cardiology, University Hospital Ostrava, 708 52 Ostrava, Czech Republic $u Benedor Cardiology Outpatient Clinic Ltd., 708 00 Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, 703 00 Ostrava, Czech Republic
245    14
$a The Agreement of a Two- and a Three-Dimensional Speckle-Tracking Global Longitudinal Strain / $c J. Plášek, T. Rychlý, D. Drieniková, O. Cisovský, T. Grézl, M. Homza, J. Václavík
520    9_
$a BACKGROUND: Two-dimensional (2D) and three-dimensional (3D) speckle-tracking echocardiography (STE) enables assessment of myocardial function. Here, we examined the agreement between 2D and 3D STE measurement of a global longitudinal strain (GLS) in patients with normal left ventricle, reduced ejection fraction, and cardiac pacing. METHODS: Our analysis included 90 consecutive patients (59% males; average age: 73.2 ± 11.2 years) examined between May 2019-December 2020, with valid 2D and 3D loops for further speckle-tracking strain analysis. Linear regression, Pearson correlation, and a Bland-Altman plot were used to quantify the association between 2D and 3D GLS and related segments, using the 17-segment American Heart Association (AHA) model. Analyses were performed in the entire study group and subgroups. Intra- and inter-observer variability of 2D and 3D GLS measurement was also performed in all participants. RESULTS: We observed a strong correlation between 2D and 3D GLS measurements (R = 0.76, p &lt; 0.001), which was higher in males (R = 0.78, p &lt; 0.001) than females (R = 0.69, p &lt; 0.001). Associated segment correlation was poor (R = 0.2-0.5, p &lt; 0.01). The correlation between 2D and 3D GLS was weaker in individuals with ventricular pacing of &gt;50% (R = 0.62, p &lt; 0.001) than &lt;50% (R = 0.8, p &lt; 0.001), and in patients with LVEF of &lt;35% (R = 0.69, p = 0.002) than &gt;35% (R = 0.72, p &lt; 0.001). Intra-observer variability for 2D and 3D GLS was 2 and 2.3%, respectively. Inter-observer variability for 2D and 3D GLS was 3.8 and 3.6%, respectively Conclusion: Overall 2D and 3D GLS were closely associated but not when analyzed per segment. It seems that GLS comparison is more representative of global shortening than local displacement. Right ventricular pacing and reduced left ventricular ejection fraction were associated with a reduced correlation between 2D and 3D GLS.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Rychlý, Tomáš $u Benedor Cardiology Outpatient Clinic Ltd., 708 00 Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, 703 00 Ostrava, Czech Republic
700    1_
$a Drieniková, Diana $u Department of Internal Medicine and Cardiology, University Hospital Ostrava, 708 52 Ostrava, Czech Republic $u Benedor Cardiology Outpatient Clinic Ltd., 708 00 Ostrava, Czech Republic
700    1_
$a Cisovský, Ondřej $u Benedor Cardiology Outpatient Clinic Ltd., 708 00 Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, 703 00 Ostrava, Czech Republic
700    1_
$a Grézl, Tomáš, $u Department of Internal Medicine and Cardiology, University Hospital Ostrava, 708 52 Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, 703 00 Ostrava, Czech Republic $1 https://orcid.org/0000000317137575 $d 1989- $7 xx0283382
700    1_
$a Homza, Miroslav $u Benedor Cardiology Outpatient Clinic Ltd., 708 00 Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, 703 00 Ostrava, Czech Republic
700    1_
$a Václavík, Jan $u Department of Internal Medicine and Cardiology, University Hospital Ostrava, 708 52 Ostrava, Czech Republic $u Faculty of Medicine, University of Ostrava, 703 00 Ostrava, Czech Republic
773    0_
$w MED00195462 $t Journal of clinical medicine $x 2077-0383 $g Roč. 11, č. 9 (2022)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35566528 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20220718 $b ABA008
991    __
$a 20230314111710 $b ABA008
999    __
$a ind $b bmc $g 1816539 $s 1168559
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 11 $c 9 $e 20220425 $i 2077-0383 $m Journal of clinical medicine $n J Clin Med $x MED00195462
GRA    __
$a SGS01/LF/2020 $p University of Ostrava
GRA    __
$a MH CZ - DRO (FNOs/2021) $p Ministry of Health
LZP    __
$a Pubmed-20220718

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...