• Je něco špatně v tomto záznamu ?

Semi-automated detection of cervical spinal cord compression with the Spinal Cord Toolbox

M. Horáková, T. Horák, J. Valošek, T. Rohan, E. Koriťáková, M. Dostál, J. Kočica, T. Skutil, M. Keřkovský, Z. Kadaňka, P. Bednařík, A. Svátková, P. Hluštík, J. Bednařík

. 2022 ; 12 (4) : 2261-2279. [pub] -

Jazyk angličtina Země Čína

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22017465

Background: Degenerative cervical spinal cord compression is becoming increasingly prevalent, yet the MRI criteria that define compression are vague, and vary between studies. This contribution addresses the detection of compression by means of the Spinal Cord Toolbox (SCT) and assesses the variability of the morphometric parameters extracted with it. Methods: Prospective cross-sectional study. Two types of MRI examination, 3 and 1.5 T, were performed on 66 healthy controls and 118 participants with cervical spinal cord compression. Morphometric parameters from 3T MRI obtained by Spinal Cord Toolbox (cross-sectional area, solidity, compressive ratio, torsion) were combined in multivariate logistic regression models with the outcome (binary dependent variable) being the presence of compression determined by two radiologists. Inter-trial (between 3 and 1.5 T) and inter-rater (three expert raters and SCT) variability of morphometric parameters were assessed in a subset of 35 controls and 30 participants with compression. Results: The logistic model combining compressive ratio, cross-sectional area, solidity, torsion and one binary indicator, whether or not the compression was set at level C6/7, demonstrated outstanding compression detection (area under curve =0.947). The single best cut-off for predicted probability calculated using a multiple regression equation was 0.451, with a sensitivity of 87.3% and a specificity of 90.2%. The inter-trial variability was better in Spinal Cord Toolbox (intraclass correlation coefficient was 0.858 for compressive ratio and 0.735 for cross-sectional area) compared to expert raters (mean coefficient for three expert raters was 0.722 for compressive ratio and 0.486 for cross-sectional area). The analysis of inter-rater variability demonstrated general agreement between SCT and three expert raters, as the correlations between SCT and raters were generally similar to those of the raters between one another. Conclusions: This study demonstrates successful semi-automated compression detection based on four parameters. The inter-trial variability of parameters established through two MRI examinations was conclusively better for Spinal Cord Toolbox compared with that of three experts' manual ratings.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22017465
003      
CZ-PrNML
005      
20220720100234.0
007      
ta
008      
220718s2022 cc f 000 0|eng||
009      
AR
024    7_
$a 10.21037/qims-21-782 $2 doi
035    __
$a (PubMed)35371944
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a cc
100    1_
$a Horáková, Magda $u Department of Neurology, University Hospital Brno, Brno, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Central European Institute of Technology, Multimodal and Functional Imaging Laboratory, Brno, Czech Republic
245    10
$a Semi-automated detection of cervical spinal cord compression with the Spinal Cord Toolbox / $c M. Horáková, T. Horák, J. Valošek, T. Rohan, E. Koriťáková, M. Dostál, J. Kočica, T. Skutil, M. Keřkovský, Z. Kadaňka, P. Bednařík, A. Svátková, P. Hluštík, J. Bednařík
520    9_
$a Background: Degenerative cervical spinal cord compression is becoming increasingly prevalent, yet the MRI criteria that define compression are vague, and vary between studies. This contribution addresses the detection of compression by means of the Spinal Cord Toolbox (SCT) and assesses the variability of the morphometric parameters extracted with it. Methods: Prospective cross-sectional study. Two types of MRI examination, 3 and 1.5 T, were performed on 66 healthy controls and 118 participants with cervical spinal cord compression. Morphometric parameters from 3T MRI obtained by Spinal Cord Toolbox (cross-sectional area, solidity, compressive ratio, torsion) were combined in multivariate logistic regression models with the outcome (binary dependent variable) being the presence of compression determined by two radiologists. Inter-trial (between 3 and 1.5 T) and inter-rater (three expert raters and SCT) variability of morphometric parameters were assessed in a subset of 35 controls and 30 participants with compression. Results: The logistic model combining compressive ratio, cross-sectional area, solidity, torsion and one binary indicator, whether or not the compression was set at level C6/7, demonstrated outstanding compression detection (area under curve =0.947). The single best cut-off for predicted probability calculated using a multiple regression equation was 0.451, with a sensitivity of 87.3% and a specificity of 90.2%. The inter-trial variability was better in Spinal Cord Toolbox (intraclass correlation coefficient was 0.858 for compressive ratio and 0.735 for cross-sectional area) compared to expert raters (mean coefficient for three expert raters was 0.722 for compressive ratio and 0.486 for cross-sectional area). The analysis of inter-rater variability demonstrated general agreement between SCT and three expert raters, as the correlations between SCT and raters were generally similar to those of the raters between one another. Conclusions: This study demonstrates successful semi-automated compression detection based on four parameters. The inter-trial variability of parameters established through two MRI examinations was conclusively better for Spinal Cord Toolbox compared with that of three experts' manual ratings.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Horák, Tomáš $u Department of Neurology, University Hospital Brno, Brno, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Central European Institute of Technology, Multimodal and Functional Imaging Laboratory, Brno, Czech Republic
700    1_
$a Valošek, Jan $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University Olomouc, Olomouc, Czech Republic $u Department of Biomedical Engineering, University Hospital Olomouc, Olomouc, Czech Republic
700    1_
$a Rohan, Tomáš $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Department of Radiology and Nuclear Medicine, University Hospital Brno, Brno, Czech Republic
700    1_
$a Koriťáková, Eva $u Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University, Brno, Czech Republic
700    1_
$a Dostál, Marek $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Department of Radiology and Nuclear Medicine, University Hospital Brno, Brno, Czech Republic
700    1_
$a Kočica, Jan $u Department of Neurology, University Hospital Brno, Brno, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Central European Institute of Technology, Multimodal and Functional Imaging Laboratory, Brno, Czech Republic
700    1_
$a Skutil, Tomáš $u Department of Neurology, University Hospital Brno, Brno, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czech Republic
700    1_
$a Keřkovský, Miloš $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Department of Radiology and Nuclear Medicine, University Hospital Brno, Brno, Czech Republic
700    1_
$a Kadaňka, Zdeněk $u Department of Neurology, University Hospital Brno, Brno, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czech Republic
700    1_
$a Bednařík, Petr $u Central European Institute of Technology, Multimodal and Functional Imaging Laboratory, Brno, Czech Republic $u Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, High Field MR Centre, Vienna, Austria $u Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Hvidovre, Denmark $u Department of Radiology, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Hvidovre, Denmark
700    1_
$a Svátková, Alena $u Central European Institute of Technology, Multimodal and Functional Imaging Laboratory, Brno, Czech Republic $u Department of Imaging Methods, Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic $u Medical University of Vienna, Department of Medicine III, Clinical Division of Endocrinology and Metabolism, Vienna, Austria
700    1_
$a Hluštík, Petr $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University Olomouc, Olomouc, Czech Republic $u Department of Neurology, University Hospital Olomouc, Olomouc, Czech Republic
700    1_
$a Bednařík, Josef $u Department of Neurology, University Hospital Brno, Brno, Czech Republic $u Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Central European Institute of Technology, Multimodal and Functional Imaging Laboratory, Brno, Czech Republic
773    0_
$w MED00200676 $t Quantitative imaging in medicine and surgery $x 2223-4292 $g Roč. 12, č. 4 (2022), s. 2261-2279
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35371944 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20220718 $b ABA008
991    __
$a 20220720100230 $b ABA008
999    __
$a ind $b bmc $g 1816599 $s 1168707
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 12 $c 4 $d 2261-2279 $e - $i 2223-4292 $m Quantitative imaging in medicine and surgery $n Quant Imaging Med Surg $x MED00200676
LZP    __
$a Pubmed-20220718

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...