Extending the application potential of capillary electrophoresis/frontal analysis for drug-plasma protein studies by combining it with mass spectrometry detection
H. Mlčochová, L. Michalcová, Z. Glatz
Language English Country Germany
Document type Journal Article
Grant support
GA19-08358S
Czech Science Foundation
- MeSH
- Electrophoresis, Capillary * methods MeSH
- Spectrometry, Mass, Electrospray Ionization MeSH
- Mass Spectrometry methods MeSH
- Blood Proteins * metabolism MeSH
- Water MeSH
- Publication type
- Journal Article MeSH
CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV-Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI-MS detection for the investigation of drug-HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first- and second-generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA-MS method. This method, in contrast to the CE/FA method with the most commonly used UV-Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA-MS method and compared with the literature data. The binding constant value of TL obtained by UV-Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug-HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22018541
- 003
- CZ-PrNML
- 005
- 20220804134839.0
- 007
- ta
- 008
- 220720s2022 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/elps.202100301 $2 doi
- 035 __
- $a (PubMed)35019169
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Mlčochová, Hana $u Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
- 245 10
- $a Extending the application potential of capillary electrophoresis/frontal analysis for drug-plasma protein studies by combining it with mass spectrometry detection / $c H. Mlčochová, L. Michalcová, Z. Glatz
- 520 9_
- $a CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV-Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI-MS detection for the investigation of drug-HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first- and second-generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA-MS method. This method, in contrast to the CE/FA method with the most commonly used UV-Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA-MS method and compared with the literature data. The binding constant value of TL obtained by UV-Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug-HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.
- 650 12
- $a krevní proteiny $x metabolismus $7 D001798
- 650 12
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
- 650 _2
- $a voda $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Michalcová, Lenka $u Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic $1 https://orcid.org/0000000248801304
- 700 1_
- $a Glatz, Zdeněk $u Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic $1 https://orcid.org/0000000334266117
- 773 0_
- $w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 43, č. 9-10 (2022), s. 955-963
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35019169 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804134833 $b ABA008
- 999 __
- $a ok $b bmc $g 1822235 $s 1169784
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 43 $c 9-10 $d 955-963 $e 20220122 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
- GRA __
- $a GA19-08358S $p Czech Science Foundation
- LZP __
- $a Pubmed-20220720