Extending the application potential of capillary electrophoresis/frontal analysis for drug-plasma protein studies by combining it with mass spectrometry detection

H. Mlčochová, L. Michalcová, Z. Glatz

. 2022 ; 43 (9-10) : 955-963. [pub] 20220122

Language English Country Germany

Document type Journal Article

Grant support
GA19-08358S Czech Science Foundation

CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV-Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI-MS detection for the investigation of drug-HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first- and second-generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA-MS method. This method, in contrast to the CE/FA method with the most commonly used UV-Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA-MS method and compared with the literature data. The binding constant value of TL obtained by UV-Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug-HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22018541
003      
CZ-PrNML
005      
20220804134839.0
007      
ta
008      
220720s2022 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/elps.202100301 $2 doi
035    __
$a (PubMed)35019169
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Mlčochová, Hana $u Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
245    10
$a Extending the application potential of capillary electrophoresis/frontal analysis for drug-plasma protein studies by combining it with mass spectrometry detection / $c H. Mlčochová, L. Michalcová, Z. Glatz
520    9_
$a CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV-Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI-MS detection for the investigation of drug-HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first- and second-generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA-MS method. This method, in contrast to the CE/FA method with the most commonly used UV-Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA-MS method and compared with the literature data. The binding constant value of TL obtained by UV-Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug-HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.
650    12
$a krevní proteiny $x metabolismus $7 D001798
650    12
$a elektroforéza kapilární $x metody $7 D019075
650    _2
$a hmotnostní spektrometrie $x metody $7 D013058
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
650    _2
$a voda $7 D014867
655    _2
$a časopisecké články $7 D016428
700    1_
$a Michalcová, Lenka $u Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic $1 https://orcid.org/0000000248801304
700    1_
$a Glatz, Zdeněk $u Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic $1 https://orcid.org/0000000334266117
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 43, č. 9-10 (2022), s. 955-963
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35019169 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220720 $b ABA008
991    __
$a 20220804134833 $b ABA008
999    __
$a ok $b bmc $g 1822235 $s 1169784
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 43 $c 9-10 $d 955-963 $e 20220122 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
GRA    __
$a GA19-08358S $p Czech Science Foundation
LZP    __
$a Pubmed-20220720

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...