Reliable P wave detection in pathological ECG signals

L. Saclova, A. Nemcova, R. Smisek, L. Smital, M. Vitek, M. Ronzhina

. 2022 ; 12 (1) : 6589. [pub] 20220421

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články, Research Support, U.S. Gov't, Non-P.H.S.

Perzistentní odkaz   https://www.medvik.cz/link/bmc22018739

Accurate automated detection of P waves in ECG allows to provide fast correct diagnosis of various cardiac arrhythmias and select suitable strategy for patients' treatment. However, P waves detection is a still challenging task, especially in long-term ECGs with manifested cardiac pathologies. Software tools used in medical practice usually fail to detect P waves under pathological conditions. Most of recently published approaches have not been tested on such the signals at all. Here we introduce a novel method for accurate and reliable P wave detection, which is success in both normal and pathological cases. Our method uses phasor transform of ECG and innovative decision rules in order to improve P waves detection in pathological signals. The rules are based on a deep knowledge of heart manifestation during various arrhythmias, such as atrial fibrillation, premature ventricular contraction, etc. By involving the rules into the decision process, we are able to find the P wave in the correct location or, alternatively, not to search for it at all. In contrast to another studies, we use three, highly variable annotated ECG databases, which contain both normal and pathological records, to objectively validate our algorithm. The results for physiological records are Se = 98.56% and PP = 99.82% for MIT-BIH Arrhythmia Database (MITDP, with MITDB P-Wave Annotations) and Se = 99.23% and PP = 99.12% for QT database. These results are comparable with other published methods. For pathological signals, the proposed method reaches Se = 96.40% and PP = 91.56% for MITDB and Se = 93.07% and PP = 88.60% for Brno University of Technology ECG Signal Database with Annotations of P wave (BUT PDB). In these signals, the proposed detector greatly outperforms other methods and, thus, represents a huge step towards effective use of fully automated ECG analysis in a real medical practice.

000      
00000naa a2200000 a 4500
001      
bmc22018739
003      
CZ-PrNML
005      
20220804135048.0
007      
ta
008      
220720s2022 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/s41598-022-10656-4 $2 doi
035    __
$a (PubMed)35449228
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Saclova, Lucie $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 12, 616 00, Brno, Czech Republic. marsanova@vut.cz $u Department of Technical Studies, College of Polytechnics Jihlava, Tolstého 16, 586 01, Jihlava, Czech Republic. marsanova@vut.cz
245    10
$a Reliable P wave detection in pathological ECG signals / $c L. Saclova, A. Nemcova, R. Smisek, L. Smital, M. Vitek, M. Ronzhina
520    9_
$a Accurate automated detection of P waves in ECG allows to provide fast correct diagnosis of various cardiac arrhythmias and select suitable strategy for patients' treatment. However, P waves detection is a still challenging task, especially in long-term ECGs with manifested cardiac pathologies. Software tools used in medical practice usually fail to detect P waves under pathological conditions. Most of recently published approaches have not been tested on such the signals at all. Here we introduce a novel method for accurate and reliable P wave detection, which is success in both normal and pathological cases. Our method uses phasor transform of ECG and innovative decision rules in order to improve P waves detection in pathological signals. The rules are based on a deep knowledge of heart manifestation during various arrhythmias, such as atrial fibrillation, premature ventricular contraction, etc. By involving the rules into the decision process, we are able to find the P wave in the correct location or, alternatively, not to search for it at all. In contrast to another studies, we use three, highly variable annotated ECG databases, which contain both normal and pathological records, to objectively validate our algorithm. The results for physiological records are Se = 98.56% and PP = 99.82% for MIT-BIH Arrhythmia Database (MITDP, with MITDB P-Wave Annotations) and Se = 99.23% and PP = 99.12% for QT database. These results are comparable with other published methods. For pathological signals, the proposed method reaches Se = 96.40% and PP = 91.56% for MITDB and Se = 93.07% and PP = 88.60% for Brno University of Technology ECG Signal Database with Annotations of P wave (BUT PDB). In these signals, the proposed detector greatly outperforms other methods and, thus, represents a huge step towards effective use of fully automated ECG analysis in a real medical practice.
650    _2
$a algoritmy $7 D000465
650    12
$a fibrilace síní $x diagnóza $7 D001281
650    _2
$a databáze faktografické $7 D016208
650    _2
$a elektrokardiografie $x metody $7 D004562
650    _2
$a lidé $7 D006801
650    12
$a počítačové zpracování signálu $7 D012815
655    _2
$a časopisecké články $7 D016428
655    _2
$a Research Support, U.S. Gov't, Non-P.H.S. $7 D013486
700    1_
$a Nemcova, Andrea $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 12, 616 00, Brno, Czech Republic
700    1_
$a Smisek, Radovan $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 12, 616 00, Brno, Czech Republic $u Institute of Scientific Instruments, The Czech Academy of Sciences, Královopolská 147, 612 64, Brno, Czech Republic
700    1_
$a Smital, Lukas $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 12, 616 00, Brno, Czech Republic
700    1_
$a Vitek, Martin $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 12, 616 00, Brno, Czech Republic
700    1_
$a Ronzhina, Marina $u Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 12, 616 00, Brno, Czech Republic
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 12, č. 1 (2022), s. 6589
856    41
$u https://pubmed.ncbi.nlm.nih.gov/35449228 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220720 $b ABA008
991    __
$a 20220804135041 $b ABA008
999    __
$a ok $b bmc $g 1822382 $s 1169982
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 12 $c 1 $d 6589 $e 20220421 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
LZP    __
$a Pubmed-20220720

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...