• Something wrong with this record ?

DNA damage modeled with Geant4-DNA: effects of plasmid DNA conformation and experimental conditions

N. D-Kondo, E. Moreno-Barbosa, V. Štěphán, K. Stefanová, Y. Perrot, C. Villagrasa, S. Incerti, B. De Celis Alonso, J. Schuemann, B. Faddegon, J. Ramos-Méndez

. 2021 ; 66 (24) : . [pub] 20211215

Language English Country Great Britain

Document type Journal Article, Research Support, Non-U.S. Gov't

The chemical stage of the Monte Carlo track-structure (MCTS) code Geant4-DNA was extended for its use in DNA strand break (SB) simulations and compared against published experimental data. Geant4-DNA simulations were performed using pUC19 plasmids (2686 base pairs) in a buffered solution of DMSO irradiated by60Co or137Csγ-rays. A comprehensive evaluation of SSB yields was performed considering DMSO, DNA concentration, dose and plasmid supercoiling. The latter was measured using the super helix density value used in a Brownian dynamics plasmid generation algorithm. The Geant4-DNA implementation of the independent reaction times method (IRT), developed to simulate the reaction kinetics of radiochemical species, allowed to score the fraction of supercoiled, relaxed and linearized plasmid fractions as a function of the absorbed dose. The percentage of the number of SB after •OH + DNA and H• + DNA reactions, referred as SSB efficiency, obtained using MCTS were 13.77% and 0.74% respectively. This is in reasonable agreement with published values of 12% and 0.8%. The SSB yields as a function of DMSO concentration, DNA concentration and super helix density recreated the expected published experimental behaviors within 5%, one standard deviation. The dose response of SSB and DSB yields agreed with published measurements within 5%, one standard deviation. We demonstrated that the developed extension of IRT in Geant4-DNA, facilitated the reproduction of experimental conditions. Furthermore, its calculations were strongly in agreement with experimental data. These two facts will facilitate the use of this extension in future radiobiological applications, aiding the study of DNA damage mechanisms with a high level of detail.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22019602
003      
CZ-PrNML
005      
20220804135818.0
007      
ta
008      
220720s2021 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1088/1361-6560/ac3a22 $2 doi
035    __
$a (PubMed)34787099
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a D-Kondo, N $u Faculty of Mathematics and Physics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
245    10
$a DNA damage modeled with Geant4-DNA: effects of plasmid DNA conformation and experimental conditions / $c N. D-Kondo, E. Moreno-Barbosa, V. Štěphán, K. Stefanová, Y. Perrot, C. Villagrasa, S. Incerti, B. De Celis Alonso, J. Schuemann, B. Faddegon, J. Ramos-Méndez
520    9_
$a The chemical stage of the Monte Carlo track-structure (MCTS) code Geant4-DNA was extended for its use in DNA strand break (SB) simulations and compared against published experimental data. Geant4-DNA simulations were performed using pUC19 plasmids (2686 base pairs) in a buffered solution of DMSO irradiated by60Co or137Csγ-rays. A comprehensive evaluation of SSB yields was performed considering DMSO, DNA concentration, dose and plasmid supercoiling. The latter was measured using the super helix density value used in a Brownian dynamics plasmid generation algorithm. The Geant4-DNA implementation of the independent reaction times method (IRT), developed to simulate the reaction kinetics of radiochemical species, allowed to score the fraction of supercoiled, relaxed and linearized plasmid fractions as a function of the absorbed dose. The percentage of the number of SB after •OH + DNA and H• + DNA reactions, referred as SSB efficiency, obtained using MCTS were 13.77% and 0.74% respectively. This is in reasonable agreement with published values of 12% and 0.8%. The SSB yields as a function of DMSO concentration, DNA concentration and super helix density recreated the expected published experimental behaviors within 5%, one standard deviation. The dose response of SSB and DSB yields agreed with published measurements within 5%, one standard deviation. We demonstrated that the developed extension of IRT in Geant4-DNA, facilitated the reproduction of experimental conditions. Furthermore, its calculations were strongly in agreement with experimental data. These two facts will facilitate the use of this extension in future radiobiological applications, aiding the study of DNA damage mechanisms with a high level of detail.
650    _2
$a počítačová simulace $7 D003198
650    _2
$a DNA $x chemie $7 D004247
650    12
$a poškození DNA $7 D004249
650    12
$a dimethylsulfoxid $7 D004121
650    _2
$a metoda Monte Carlo $7 D009010
650    _2
$a konformace nukleové kyseliny $7 D009690
650    _2
$a plazmidy $7 D010957
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Moreno-Barbosa, E $u Faculty of Mathematics and Physics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico $1 https://orcid.org/0000000211142640
700    1_
$a Štěphán, V $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic
700    1_
$a Stefanová, K $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic
700    1_
$a Perrot, Y $u Laboratoire de Dosimétrie des Rayonnements Ionisants, Institut de Radioprotection et Sûreté Nucléaire, Fontenay aux Roses, BP. 17, F-92262, France $1 https://orcid.org/0000000190435857
700    1_
$a Villagrasa, C $u Laboratoire de Dosimétrie des Rayonnements Ionisants, Institut de Radioprotection et Sûreté Nucléaire, Fontenay aux Roses, BP. 17, F-92262, France
700    1_
$a Incerti, S $u Univ. Bordeaux, CNRS/IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France $1 https://orcid.org/0000000206192053
700    1_
$a De Celis Alonso, B $u Faculty of Mathematics and Physics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico $1 https://orcid.org/0000000321241084
700    1_
$a Schuemann, J $u Department of Radiation Oncology, Massachusets General Hospital and Hardvard Medical School, Boston, MA, United States of America $1 https://orcid.org/0000000275548818
700    1_
$a Faddegon, B $u Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, United States of America
700    1_
$a Ramos-Méndez, J $u Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, United States of America $1 https://orcid.org/0000000281065142
773    0_
$w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 66, č. 24 (2021)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34787099 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220720 $b ABA008
991    __
$a 20220804135811 $b ABA008
999    __
$a ok $b bmc $g 1822990 $s 1170845
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 66 $c 24 $e 20211215 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
LZP    __
$a Pubmed-20220720

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...