DNA damage modeled with Geant4-DNA: effects of plasmid DNA conformation and experimental conditions
N. D-Kondo, E. Moreno-Barbosa, V. Štěphán, K. Stefanová, Y. Perrot, C. Villagrasa, S. Incerti, B. De Celis Alonso, J. Schuemann, B. Faddegon, J. Ramos-Méndez
Language English Country Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Dimethyl Sulfoxide * MeSH
- DNA chemistry MeSH
- Nucleic Acid Conformation MeSH
- Monte Carlo Method MeSH
- Plasmids MeSH
- Computer Simulation MeSH
- DNA Damage * MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The chemical stage of the Monte Carlo track-structure (MCTS) code Geant4-DNA was extended for its use in DNA strand break (SB) simulations and compared against published experimental data. Geant4-DNA simulations were performed using pUC19 plasmids (2686 base pairs) in a buffered solution of DMSO irradiated by60Co or137Csγ-rays. A comprehensive evaluation of SSB yields was performed considering DMSO, DNA concentration, dose and plasmid supercoiling. The latter was measured using the super helix density value used in a Brownian dynamics plasmid generation algorithm. The Geant4-DNA implementation of the independent reaction times method (IRT), developed to simulate the reaction kinetics of radiochemical species, allowed to score the fraction of supercoiled, relaxed and linearized plasmid fractions as a function of the absorbed dose. The percentage of the number of SB after •OH + DNA and H• + DNA reactions, referred as SSB efficiency, obtained using MCTS were 13.77% and 0.74% respectively. This is in reasonable agreement with published values of 12% and 0.8%. The SSB yields as a function of DMSO concentration, DNA concentration and super helix density recreated the expected published experimental behaviors within 5%, one standard deviation. The dose response of SSB and DSB yields agreed with published measurements within 5%, one standard deviation. We demonstrated that the developed extension of IRT in Geant4-DNA, facilitated the reproduction of experimental conditions. Furthermore, its calculations were strongly in agreement with experimental data. These two facts will facilitate the use of this extension in future radiobiological applications, aiding the study of DNA damage mechanisms with a high level of detail.
Faculty of Mathematics and Physics Sciences Benemérita Universidad Autónoma de Puebla Puebla Mexico
Univ Bordeaux CNRS IN2P3 CENBG UMR 5797 F 33170 Gradignan France
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22019602
- 003
- CZ-PrNML
- 005
- 20220804135818.0
- 007
- ta
- 008
- 220720s2021 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1088/1361-6560/ac3a22 $2 doi
- 035 __
- $a (PubMed)34787099
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a D-Kondo, N $u Faculty of Mathematics and Physics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
- 245 10
- $a DNA damage modeled with Geant4-DNA: effects of plasmid DNA conformation and experimental conditions / $c N. D-Kondo, E. Moreno-Barbosa, V. Štěphán, K. Stefanová, Y. Perrot, C. Villagrasa, S. Incerti, B. De Celis Alonso, J. Schuemann, B. Faddegon, J. Ramos-Méndez
- 520 9_
- $a The chemical stage of the Monte Carlo track-structure (MCTS) code Geant4-DNA was extended for its use in DNA strand break (SB) simulations and compared against published experimental data. Geant4-DNA simulations were performed using pUC19 plasmids (2686 base pairs) in a buffered solution of DMSO irradiated by60Co or137Csγ-rays. A comprehensive evaluation of SSB yields was performed considering DMSO, DNA concentration, dose and plasmid supercoiling. The latter was measured using the super helix density value used in a Brownian dynamics plasmid generation algorithm. The Geant4-DNA implementation of the independent reaction times method (IRT), developed to simulate the reaction kinetics of radiochemical species, allowed to score the fraction of supercoiled, relaxed and linearized plasmid fractions as a function of the absorbed dose. The percentage of the number of SB after •OH + DNA and H• + DNA reactions, referred as SSB efficiency, obtained using MCTS were 13.77% and 0.74% respectively. This is in reasonable agreement with published values of 12% and 0.8%. The SSB yields as a function of DMSO concentration, DNA concentration and super helix density recreated the expected published experimental behaviors within 5%, one standard deviation. The dose response of SSB and DSB yields agreed with published measurements within 5%, one standard deviation. We demonstrated that the developed extension of IRT in Geant4-DNA, facilitated the reproduction of experimental conditions. Furthermore, its calculations were strongly in agreement with experimental data. These two facts will facilitate the use of this extension in future radiobiological applications, aiding the study of DNA damage mechanisms with a high level of detail.
- 650 _2
- $a počítačová simulace $7 D003198
- 650 _2
- $a DNA $x chemie $7 D004247
- 650 12
- $a poškození DNA $7 D004249
- 650 12
- $a dimethylsulfoxid $7 D004121
- 650 _2
- $a metoda Monte Carlo $7 D009010
- 650 _2
- $a konformace nukleové kyseliny $7 D009690
- 650 _2
- $a plazmidy $7 D010957
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Moreno-Barbosa, E $u Faculty of Mathematics and Physics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico $1 https://orcid.org/0000000211142640
- 700 1_
- $a Štěphán, V $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic
- 700 1_
- $a Stefanová, K $u Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic
- 700 1_
- $a Perrot, Y $u Laboratoire de Dosimétrie des Rayonnements Ionisants, Institut de Radioprotection et Sûreté Nucléaire, Fontenay aux Roses, BP. 17, F-92262, France $1 https://orcid.org/0000000190435857
- 700 1_
- $a Villagrasa, C $u Laboratoire de Dosimétrie des Rayonnements Ionisants, Institut de Radioprotection et Sûreté Nucléaire, Fontenay aux Roses, BP. 17, F-92262, France
- 700 1_
- $a Incerti, S $u Univ. Bordeaux, CNRS/IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France $1 https://orcid.org/0000000206192053
- 700 1_
- $a De Celis Alonso, B $u Faculty of Mathematics and Physics Sciences, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico $1 https://orcid.org/0000000321241084
- 700 1_
- $a Schuemann, J $u Department of Radiation Oncology, Massachusets General Hospital and Hardvard Medical School, Boston, MA, United States of America $1 https://orcid.org/0000000275548818
- 700 1_
- $a Faddegon, B $u Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, United States of America
- 700 1_
- $a Ramos-Méndez, J $u Department of Radiation Oncology, University of California San Francisco, San Francisco, CA, United States of America $1 https://orcid.org/0000000281065142
- 773 0_
- $w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 66, č. 24 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34787099 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220720 $b ABA008
- 991 __
- $a 20220804135811 $b ABA008
- 999 __
- $a ok $b bmc $g 1822990 $s 1170845
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 66 $c 24 $e 20211215 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
- LZP __
- $a Pubmed-20220720