Immediate dentin sealing: effect of sandblasting on the layer thickness
T. Kovalsky, I. Voborna, T. Ingr, Y. Morozova, E. Misova, M. Hepova
Jazyk angličtina Země Slovensko
Typ dokumentu pozorovací studie, práce podpořená grantem
- MeSH
- dentinová adheziva * klasifikace MeSH
- lidé MeSH
- mikroskopie MeSH
- moláry účinky léků MeSH
- oxid hlinitý MeSH
- pískování zubů * metody MeSH
- statistika jako téma MeSH
- zubní sklovina diagnostické zobrazování účinky léků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- pozorovací studie MeSH
- práce podpořená grantem MeSH
OBJECTIVES: The objective of this study was to observe and to measure the impact of corundum sandblasting on the thickness of the Immediate dentin sealing layer. METHODS: 20 recently extracted molars were collected and divided randomly into two groups. A standardized preparation was performed on each tooth and the Optibond FL dentin bonding agent (Kerr, Orange, USA) was applied on the prepared surface according to the manufacturer’s instructions. The surface was then partially sandblasted. RONDOflex plus 360 (KaVo, Bieberach an der Riss, Germany) and Airsonic Mini-Sandblaster (Hager et Werken, Duisburg, Germany) were used. Microscope observations were made. RESULTS: The arithmetic mean of the Optibond FL dentin bonding agent film thickness was 48.72 μm (Group 1=45.55 μm and Group 2=51.88 μm). The dentin bonding agent layer thickness was reduced to the average value of 17,12 μm by RONDOflex plus 360 sandblasting (Group 1). The zero value was recorded in 16 % of the locations. The Airsonic Mini-Sandblaster sandblasting changed the average thickness of the dentin bonding agent layer to 13.25 μm with 31 % of zero values (Group 2). CONCLUSION: The results of this research lead to a reflection on modifications of the immediate dentin sealing procedure (Tab. 4, Fig. 3, Ref. 28).
Department of Experimental Physics Faculty of Science Palacky University Olomouc Czech Republic
Department of Physical Chemistry Faculty of Science Palacky University Olomouc Czech Republic
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22026096
- 003
- CZ-PrNML
- 005
- 20230110133728.0
- 007
- ta
- 008
- 221102s2022 xo ad fs 000 0|eng||
- 009
- AR
- 024 0_
- $a 10.4149/BLL_2022_015 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xo
- 100 1_
- $a Kovalský, Tomáš $7 xx0258223 $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic
- 245 10
- $a Immediate dentin sealing: effect of sandblasting on the layer thickness / $c T. Kovalsky, I. Voborna, T. Ingr, Y. Morozova, E. Misova, M. Hepova
- 504 __
- $a Literatura
- 520 9_
- $a OBJECTIVES: The objective of this study was to observe and to measure the impact of corundum sandblasting on the thickness of the Immediate dentin sealing layer. METHODS: 20 recently extracted molars were collected and divided randomly into two groups. A standardized preparation was performed on each tooth and the Optibond FL dentin bonding agent (Kerr, Orange, USA) was applied on the prepared surface according to the manufacturer’s instructions. The surface was then partially sandblasted. RONDOflex plus 360 (KaVo, Bieberach an der Riss, Germany) and Airsonic Mini-Sandblaster (Hager et Werken, Duisburg, Germany) were used. Microscope observations were made. RESULTS: The arithmetic mean of the Optibond FL dentin bonding agent film thickness was 48.72 μm (Group 1=45.55 μm and Group 2=51.88 μm). The dentin bonding agent layer thickness was reduced to the average value of 17,12 μm by RONDOflex plus 360 sandblasting (Group 1). The zero value was recorded in 16 % of the locations. The Airsonic Mini-Sandblaster sandblasting changed the average thickness of the dentin bonding agent layer to 13.25 μm with 31 % of zero values (Group 2). CONCLUSION: The results of this research lead to a reflection on modifications of the immediate dentin sealing procedure (Tab. 4, Fig. 3, Ref. 28).
- 650 _7
- $a lidé $7 D006801 $2 czmesh
- 650 _7
- $a oxid hlinitý $7 D000537 $2 czmesh
- 650 17
- $a pískování zubů $x metody $7 D020906 $2 czmesh
- 650 17
- $a dentinová adheziva $x klasifikace $7 D017220 $2 czmesh
- 650 _7
- $a moláry $x účinky léků $7 D008963 $2 czmesh
- 650 _7
- $a zubní sklovina $x diagnostické zobrazování $x účinky léků $7 D003743 $2 czmesh
- 650 _7
- $a statistika jako téma $7 D013223 $2 czmesh
- 650 _7
- $a mikroskopie $7 D008853 $2 czmesh
- 655 _7
- $a pozorovací studie $7 D064888 $2 czmesh
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 700 1_
- $a Voborná, Iva $7 xx0238050 $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic
- 700 1_
- $a Ingr, T. $7 _AN115193 $u Department of Experimental Physics, Faculty of Science, Palacky University, Olomouc, Czech Republic $u Department of Physical Chemistry, Faculty of Science, Palacky University, Olomouc, Czech Republic
- 700 1_
- $a Morozova, Yulia $7 xx0233946 $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic
- 700 1_
- $a Míšová, Eva, $d 1983- $7 xx0238051 $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic
- 700 1_
- $a Hepová, Monika $7 xx0266360 $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic
- 773 0_
- $t Bratislavské lekárske listy $x 0006-9248 $g Roč. 123, č. 2 (2022), s. 87-91 $w MED00000845
- 856 41
- $u http://www.elis.sk/download_file.php?product_id=7529&session_id=5hob67buame1h4jbqk1qin6737 $y plný text volně přístupný
- 910 __
- $a ABA008 $b online $c 1067 $y p $z 0
- 990 __
- $a 20221101161338 $b ABA008
- 991 __
- $a 20230110133724 $b ABA008
- 999 __
- $a ok $b bmc $g 1855740 $s 1177400
- BAS __
- $a 3
- BMC __
- $a 2022 $b 123 $c 2 $d 87-91 $i 0006-9248 $m Bratislavské lekárske listy $x MED00000845
- LZP __
- $c NLK189 $d 20221217 $a NLK 2022-22/kv